III.12
EN
Operating instructions SATAjet 4000-110/-120 (DIGITAL)
[11-4]
3. Positioning and assembly of control knob [c]
•
Position of knob [11-2] has to be according to illustration (line in the
knob has to be in vertical position)
•
Hand-tighten screw [11-1] (Torx T20) in the knob – hold knob in the
position while tightening
9.8. Replacing the Battery (DIGITAL)
[12-1] and [12-2]
Warning! Risk of explosion!
•
Replace the battery outside of explosive areas only!
•
Strictly observe the safety instructions in chapter 6.4.2!
According to the intensity of use, the battery will last between 1 to 3 years.
When the battery symbol appears on the pressure display, the battery has
to be exchanged within the next 2 to 3 weeks. The battery is empty when
no pressure is indicated with the spray gun inlet pressure exceeding 0.2
bar / 3 psi (trigger fully pulled). Tighten new battery lid with pre-assembled
sealing (
Art. No. 165993
including battery) and check functionality.
10. Troubleshooting
Malfunction
Cause
Corrective Action
Fluttering/spitting
spray fan or air bub-
bles appearing in the
gravity flow cup
Fluid tip has not been
properly tightened
Tighten fluid tip
[2-1]
with universal spanner
Air distribution ring is
damaged or clogged.
Replace air distribu-
tion ring, as it will be
damaged during disas-
sembly
EN-Content-BAL-SATAjet 4000 -110 -120.indd 12
29.10.2012 13:43:42
Summary of Contents for SATAjet 4000 Series
Page 38: ...BAL_jet4000_2 indd 18 29 10 2012 12 23 01...
Page 57: ...3 3 5 3 3 3 4 3 2 3 1 Outro BAL SATAjet 4000 110 120 indd 57 24 10 2012 15 05 50...
Page 60: ...9 9 1 9 3 9 2 1 2 3 Outro BAL SATAjet 4000 110 120 indd 60 24 10 2012 15 06 00...
Page 61: ...10 10 1 10 2 10 4 10 5 10 3 10 6 Outro BAL SATAjet 4000 110 120 indd 53 24 10 2012 15 05 41...
Page 63: ...13 14 Outro BAL SATAjet 4000 110 120 indd 55 24 10 2012 15 05 46...