8  Technical Data

8.1 

Dimensions and Weights

Sartolab

®

 RF 50 – 250

Sartolab

®

 RF 50

Sartolab

®

 RF 150

Sartolab

®

 RF 250

Unit

Value

Value

Value

Height

mm

116

142

180

Outer diameter, max.

mm

78

100

100

Product weight

g

51

100

114

Sartolab

®

 RF 500 – 1000

Sartolab

®

 RF

 

500

Sartolab

®

 RF 1000

Unit

Value

Value

Height

mm

206

318

Outer diameter, max.

mm

124

124

Product weight

g

115

257

Sartolab

®

 BT 150 – 250

Sartolab

®

 BT 150

Sartolab

®

 BT 250

Unit

Value

Value

Height

mm

88

103

Outer diameter, max.

mm

100

100

Funnel to fit bottle neck size

mm

45

45

Product weight

g

61

68

Sartolab

®

 BT 500 – 1000

Sartolab

®

 BT 500

Sartolab

®

 BT 1000

Unit

Value

Value

Height

mm

114

171

Outer diameter, max.

mm

124

124

Funnel to fit bottle neck size

mm

45

45

Product weight

g

102

135

Summary of Contents for Sartolab BT 1000

Page 1: ...Instructions for Use Sartolab RF BT RF 50 1000 BT 150 1000 Filtration Unit for Vacuum Filtration 1000096582...

Page 2: ......

Page 3: ...n 9 3 5 Product Symbols 9 4 Process Preparation 10 4 1 Scope of Delivery 10 4 2 Unpacking 10 4 3 Assembling the Receiver Bottle Sartolab BT 150 1000 Only 10 4 4 Inserting Product into a Rack Sartolab...

Page 4: ...perating Conditions 16 8 4 1 Operating Pressure for Vacuum Source 16 8 4 2 Filtration Applications 16 8 4 3 Liquids 17 8 4 4 Filtration Capacity 17 8 5 Membrane Filter 19 8 6 Sterility 20 8 7 Approved...

Page 5: ...E Sartolab BT 250 180E13 E Sartolab BT 500 180E14 E Sartolab BT 1000 180E15 E 180F15 E 1 2 Target Groups These instructions are designed for the following target groups The target groups must possess...

Page 6: ...st be poured into the funnel The product can be inserted into a support manifold In this way the support manifold applies a vacuum to the product and filtration can be performed simultaneously The sup...

Page 7: ...r cause hazards that are difficult to identify t Only operate the product when it is safe and in perfect working order 2 4 Spilled Liquids If liquids are spilled e g due to the product falling over or...

Page 8: ...eceiver bottle example Pos Name Description 1 Lid Removable 2 Funnel For pouring in the liquid to be filtered Contains the membrane filter 3 Adapter Connects the funnel to the collection tube or the r...

Page 9: ...connection of the vacuum filtration unit to a vacuum source The vacuum tube adapter holds the vacuum tube of the vacuum source 3 4 Vacuum Filtration The vacuum draws the liquids through the membrane...

Page 10: ...ed individually in sterile packaging Exception For the non sterile versions the screw caps are included in the product packages The sterile screw cap must be unpacked immediately before use Procedure...

Page 11: ...re supplied without a vacuum tube adapter 1 Fig 3 Product placed in a rack example Pos Name 1 Rack Material 1 rack or 1 holder for 50 mL centrifuge tubes Procedure t Insert the product into the chosen...

Page 12: ...e vacuum source to the tube adapter The vacuum tube must not come loose during filtration 5 Use 5 1 Filling the Funnel CAUTION Danger of injury due to contamination of the vacuum source Excess liquid...

Page 13: ...ons for the vacuum source or support manifold t Remove the product from the support manifold see instructions for the support manifold or pull the vacuum tube out off the tube adapter t Unscrew the fu...

Page 14: ...ns on the proper decontamination and declaration for transport and disposal Procedure t If the product has come into contact with hazardous substances Decontaminate the product 7 2 Disposing of the Pr...

Page 15: ...000 Sartolab RF500 Sartolab RF 1000 Unit Value Value Height mm 206 318 Outer diameter max mm 124 124 Product weight g 115 257 Sartolab BT 150 250 Sartolab BT 150 Sartolab BT 250 Unit Value Value Heigh...

Page 16: ...0 100 Sartolab RF 150 10001 C 20 70 1 Storage at temperatures of 20 C 0 C is dependent on the liquid type and the storage conditions We recommend conducting a storage test for the solution before use...

Page 17: ...ation Capacity Sartolab RF 50 250 Sartolab RF 50 Sartolab RF 50 Sartolab RF 50 Unit Value Value Value Type 180E01 2 180F01 2 180E01 E8 Filling volume max mL 50 50 50 Funnel volume mL 50 50 50 Receiver...

Page 18: ...ab RF 1000 Sartolab RF 1000 Unit Value Value Type 180E05 E 180F05 E Filling volume max mL 1000 1000 Funnel volume mL 1000 1000 Receiver bottle volume mL 1000 1000 Hold up volume mL 4 1 4 1 Sartolab BT...

Page 19: ...43 43 Pore size m 0 22 0 45 0 22 0 45 0 10 0 22 0 45 Membrane type PES Sartolab RF 500 1000 Sartolab RF 500 Sartolab RF 1000 Unit Value Value Membrane diameter mm 100 100 Effective filtration surface...

Page 20: ...idually in sterile packaging Exception non sterile versions Sartolab RF 50 non sterile 180E01 E8 and 180F01 E8 Product not suitable for autoclaving 8 7 Approved Products 8 7 1 Receiver Bottle Sartolab...

Page 21: ...PS Membrane Filter Polyethersulfone PES Collection tube Polypropylene PP Receiver bottle Polystyrene PS Adapter tube adapter screw cap Polyethylene HDPE Gasket vacuum filter installed in funnel Polye...

Page 22: ...of the accessories that can be ordered For information on other products please contact Sartorius Item Quantity Order number Sartolab receiver bottle including screw cap 150 mL 12 180 22 E 250 mL 12...

Page 23: ...feminine forms are used to facilitate legibility in these instructions and always simultaneously denote the other gender as well Copyright notice This instruction manual including all of its component...

Reviews: