background image

98648-014-52

98648-014-52

Installation Instructions

Sartorius PMA.Quality 

Model PMA7501-Y | -Y00W | -Y00U

Electronic Paint-mixing Scale for Use in Zone 2  

Potentially Explosive Atmospheres

Summary of Contents for PMA.Quality PMA7501-Y

Page 1: ...98648 014 52 Installation Instructions Sartorius PMA Quality Model PMA7501 Y Y00W Y00U Electronic Paint mixing Scale for Use in Zone 2 Potentially Explosive Atmospheres...

Page 2: ...g applications 8 c key Clear and REC key for paint mixing applications 9 L key ENTER and MEM key for paint mixing applications 10 Display 11 Weighing pan 12 Interfaces D Sub plug 9 contact 13 Connecti...

Page 3: ...ake sure you observe the warning and safety information in its entirety during installation and opera tion as well as while performing mainte nance and repair work on the equipment e g EN60079 14 The...

Page 4: ...treme temperatures aggressive chemical vapors moisture shocks or vibrations The equipment must be used indoors To ensure safety disconnect the equip ment from power before connecting or disconnecting...

Page 5: ...xpose the scale to aggressive chemical vapors or to extreme tempera tures moisture shocks or vibration The allowable operating temperature range during operation is 0 C to 40 C 32 F to 104 F Make sure...

Page 6: ...pment Equipment Supplied Scale Weighing pan Power supply YPS04 Y Setting Up the Scale Choose a suitable place to set up the scale Avoid exposure to drafts heat moisture and vibration Make sure to read...

Page 7: ...of a certified technician Ground the scale Connect the cable to the grounding terminal 14 Insert the right angle plug into the IEC jack 13 on the scale Note When installing the scale in Zone 2 potent...

Page 8: ...la is reached Remove the filled paint can from the weighing pan Never use a hammer to close the lid of a paint can while it is still on the weighing pan Otherwise you will damage the weighing system 8...

Page 9: ...symbol appears in this case g Pour in additional components until the desired weight of your formula is reached Remove the filled paint can from the weighing pan Important Note If you zero the displa...

Page 10: ...0 Important Note The flashing arrow n on the display means that the weight shown is not verified for use in legal metrology not legal for trade Example As you pour in the components of your formula th...

Page 11: ...the S key 4 When you then press the L key MEM 9 the scale will automatically calculate and display the amounts of paint in g to add for each of the other components that you already poured in This mod...

Page 12: ...display 9 Press the y key 4 several times to correct the value to 200 0 g 10 Press the L key MEM 9 COR 01 11 1 Add the first component C1 is displayed 1 5 g 12 Pour in paint until 0 0 g is displayed 0...

Page 13: ...r connection to AC power and before each calibration adjustment allow the scale to warm up for approx 30 min Hold down the U key 5 for 2 sec When 5000 is displayed release the key Center the calibrati...

Page 14: ...u item in the second level Press the L key ENTER to select the third level Level 3 The menu items in the third level Level 3 will be displayed Use the RS keys to select the desired menu item Press the...

Page 15: ...Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER APPLICATION RS keys select APPLICATION L key press ENTER Program RS keys select PROGRAM WEIGH L key ENTER o TOGGLE RS keys select TOGGLE Pre...

Page 16: ...will automatically be locked preventing further weighing operations Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER EXTRAS RS keys select EXTRAS Press the L key ENTER LOCK RS keys select...

Page 17: ...ally appear You can now enter a new password or confirm each blinking dash by pressing the L key ENTER Blank spaces are then displayed Level 1 Level 2 Level 3 Level 4 INPUT RS keys select INPUT PASSWO...

Page 18: ...t first be entered Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER RESET RS keys select RESET Press the L key ENTER MENU RS keys select MENU Press the L key ENTER YES Use the RS keys to se...

Page 19: ...ther area changes constantly Too much vibration or Access the menu to select the scale is exposed to draft the appropriate code to adapt the scale to the particular weighing environment refer to Menu...

Page 20: ...r ensured when There is visible damage to the AC adapt er power supply The equipment no longer functions properly The equipment has been stored for a relatively long period under unfavorable condition...

Page 21: ...r further information about disposal and recycling options please contact your local service staff The partners listed on the following website can be used for disposals within the EU 1 Go to http www...

Page 22: ...mm 233 Scale housing W D H mm 233 329 391 Net weight approx kg 3 3 Calibration weight kg 5 class F2 or better Power Supply YPS04 Y Input 100 240 Vac 50 60 Hz 18 V A max Interface RS 232C Format 7 bit...

Page 23: ...housing W D H mm 233 329 391 Net weight approx kg 3 3 Calibration weight kg 5 class F2 or better Power Supply YPS04 Y Input 100 240 Vac 50 60 Hz 18 V A max Interface USB virtual serial interface Forma...

Page 24: ...I 1 80 m YCO13 USB data cable YCC01 0040M3 Note Only connect or disconnect the data cable YCO12 YCO13 if the devices at both ends of the cable are switched off Screw the D SUB plug on to the PMA7501 Y...

Page 25: ...ou wish to change the port Therefore choose one USB port that can permanently or regularly be used to connect the balance Switch off the balance Unplug the balance from the mains Connect the USB cable...

Page 26: ...l Panel System Hardware Device Manager Open the Connections submenu Double click on USB Serial Port Select Port Settings Advanced Changing Latency Time Open the settings for the USB serial port follow...

Page 27: ...27...

Page 28: ...28...

Page 29: ...29...

Page 30: ...30...

Page 31: ...31...

Page 32: ...32...

Page 33: ...33...

Page 34: ...34...

Page 35: ...35...

Page 36: ...36...

Page 37: ...37...

Page 38: ...orms are used to facilitate legibility in these instructions and always simultaneously denote the other gender as well Copyright notice This instruction manual including all of its components is prote...