background image

                                                                                                                                               

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual       

-Installation 
-Operation

 

SR-1k-TL 
SR -1.5k-TL 
SR -2k-TL

 

Summary of Contents for SR -1.5k-TL

Page 1: ...1 User Manual Installation Operation SR 1k TL SR 1 5k TL SR 2k TL...

Page 2: ...5 4 4 Further Information 5 Installation 16 5 1 Safety 16 5 2 Mounting Instructions 16 5 3 Safety Clearance 17 5 4 Mounting Procedure 18 5 4 1 Mounting with bracket 18 5 4 2 Mounting without bracket 2...

Page 3: ...3 7 4 Instructions of Safety Standard selection when power up 37 7 5 State Information 39 8 Recycling and Disposal 40 9 Troubleshooting 41 10 Abbreviation 42 11 Contact...

Page 4: ...r manual all time available in case of emergency 1 2 Symbols Used DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a...

Page 5: ...re only for qualified personnel who are intended to install or uninstall the Grid Tie Solar Inverter WARNING Do not use this product unless it has been successfully installed by qualified personnel in...

Page 6: ...tion service recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations Please contact your dealer to get the...

Page 7: ...generators and public grid Danger of hot surface The components inside the inverter will release a log of heat during operation DO NOT touch aluminum housing during operating An error has occurred Ple...

Page 8: ...Product Safety Act in Europe Standards Association of Australian The inverter complies with the requirement of the AS4777 CE Mark Equipment with the CE mark fulfils the basic requirements of the Guid...

Page 9: ...9 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination...

Page 10: ...les more PV panels connected Wide MPP voltage range ensure high yield under various weather conditions High MPP tracking accuracy ensure the minimum power loses during converting Complete set of prote...

Page 11: ...60Hz 50Hz 60Hz 50Hz 60Hz Max AC Current 5 8A 9 0A 12 0A Grid Voltage Range 185 276V 185 276V 185 276V Grid Frequency Range 45 55Hz 55 65Hz 45 55Hz 55 65Hz 45 55Hz 55 65Hz Power Factor 0 99 0 99 0 99 T...

Page 12: ...P 65 According to IEC 60529 Cooling Concept Natural convection Mounting Information Wall Bracket General Data Operating Temperature Range 20 C to 60 C derating above 45 Relative Humidity 0 to 98 no co...

Page 13: ...mpleteness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing A B C D E F G H Object Quantity Description A 1 inverter B 1 pair DC...

Page 14: ...ance Front Bottom Object Description A Removable front shield B LED light Green RUN C LED light Red FAULT D LED light Yellow COM E Function key for displays and choice of language F Monitoring LCD wit...

Page 15: ...cation You can identify the inverter by the side nameplate Information such as serial number SN type of the inverter as well as inverter specifications are specified on the side name plate The name pl...

Page 16: ...H VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and regulations NOTICE NOTICE due to the inappropriate...

Page 17: ...e device is properly fixed to the wall It is not recommended that the inverter is exposed to the strong sunshine because the excess heating might lead to power reduction The ambient temperature of ins...

Page 18: ...wall according to the wall mounting bracket in the carton box Depth 50mm 250 213 First according to the marks drill 4 holes in the wall Then place four expansion tubes in the holes using a rubber hamm...

Page 19: ...irst check the 4 holes in the backside of the inverter Then lift the inverter carefully align the 4 holes in the inverter and the 4 hooks on the bracket and finally attach the inverter to the hooks sl...

Page 20: ...ccording to the paper installation position scale packed in the carton box 2 First according to the marks drill 4 holes in the wall Then place four expansion tubes in the holes using a rubber hammer N...

Page 21: ...rter carefully align the 4 holes in the inverter and the 4 screws in the wall and finally attach the inverter to the screws slightly 4 Please carefully check the accessories and original carton to mak...

Page 22: ...he inverter as the picture showed below 5 5 2 Safety lock without the wall mounting bracket After the inverter is hang up on the wall install the lock bracket on the aluminium radiator at the Lower Ri...

Page 23: ...ckle Diameter 5 7 mm B Vertical Clearance 8 15 mm C Horizontal Clearance 12 20 mm Stainless solid hanger and secured lock cylinder NOTICE For further maintenance and possible repair please keep the ke...

Page 24: ...ses PE connection DANGER DANGER to life due to potential fire or electricity shock With the inverter powered comply with all prevailing national regulations on accidents prevention This inverter will...

Page 25: ...sor will detect the volume of the leakage current and compare it with the pre set value if the leakage current exceeds the permitted range the RCD will disconnect the inverter from the AC load 2 Assem...

Page 26: ...g Then insert the stripped N L and PE cable accordingly to the corresponding position and fully tighten the screws e Aim the terminals on the straight plug to the holes of the grommet and then compres...

Page 27: ...y instructions described here are disregarded then neither safety nor compliance with the technical data can be guaranteed For protection against electric shock PV connectors must be isolated from the...

Page 28: ...r with sealing caps Plugged parts are watertight IP67 They can not be used permanently under water Do not lay the MC PV connectors on the roof surface See the MC catalogue 2 Solar line for technical d...

Page 29: ...ill 3 Open end spanner PV MS 1 set 2 pieces Order No 32 6024 ill 4 PV WZ AD GWD socket wrench insert to tighten Order No 32 6006 ill 5 PV SSE AD4 socket wrench insert to secure PV SSE AD4 Order No 32...

Page 30: ...tion may exceed the permitted limits Check dimension b according to the following table ill 10 Strip cable insulation L 6 7 5 mm Take care not to cut individual strands Recommended tool Stripping plie...

Page 31: ...ning torque must be adapted to the solar cables used in each specific case Typical values lie in a range between 2 5 Nm to 3 Nm Plugging and unplugging the cable coupler without safety lock clip PV SS...

Page 32: ...communications that is up to 50 inverters can be connected one by one through these 2 plugs and the cables the upper computer can communicate with these inverters via a single signal cable at the sam...

Page 33: ...it is easy for user to check and set the data In addition the user can press the function key to illuminate the LCD screen NOTICE Inverter is not an aligned measuring instrument for current voltage or...

Page 34: ...Pac xxxx W The top line Line 1 shows current state information by default and by pressing function key it will display different operating information as the following flow chart and table NOTICE Mak...

Page 35: ...xxxx W Iac Pac xxxx W E total Pac xxxx W Vpv Pac xxxx W Ipv Pac xxxx W E today Pac xxxx W Vac Pac xxxx W Model Pac xxxx W Ver Pac xxxx W Set language Pac xxxx W Frequency Pac xxxx W S N WiFi Pac xxxx...

Page 36: ...Firmware version Set Language Several languages are provided for users reference to 7 3 for further information Vac The grid voltage S N WiFi Displays the serial number of the WiFi card such as no Wi...

Page 37: ...verters Only perform this operation when the accumulative generated electricity is less than 1KWh 2 Operation steps are as following a Power on the inverter with only DC side connected while disconnec...

Page 38: ...38 c When the LCD displays your desired Safety Standard hold the Function button for 5 seconds or more until it shows Safety Standard OK d The Safety Standard setup is now completed...

Page 39: ...y Loss No Utility Island PV Over Voltage Input voltage too high Over Temperature Temperature abnormal Isolation Fault Isolation failure Relay Check Fail Output relay failure DC INJ High Output DC inje...

Page 40: ...the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must find an approved coll...

Page 41: ...y Loss 1 Grid is not connected 2 Check grid connection cables 3 Check grid usability 4 If grid is ok and the problem persists maybe the fuse in the inverter is open please call service Over Temperatur...

Page 42: ...aximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of electricity generated by PV modules VDE 0126 1...