1  Template 

Instructions 

<<Delete before 
use>> 

 

 

4.3  Menu Functions - Settings section 

 

Display 

Description 

Options / Notes 

Pump Select? 

<Internal> 

 

 

Shows the currently selected pump 
that will be operated by pressing the 
pump on / off switch (TAP symbol) 
Use the select button (

) to change 

 
Note: if your water pump stops 
working, this setting may have been 
inadvertently changed. 

<INTERNAL> = The internal 
pump will be operated by the 
pump switch 
<EXTERNAL> = The External 
pump will be operated by the 
pump switch 
<BOTH> = Both the Internal 
and External pumps will be 
operated simultaneously by 
the pump switch 

Water Tank Fill? 

<Start 1 Min> 

 

 

Allows operation of the External 
pump for a period of one minute  
(for filling the internal tank from the 
external tank) 
Use the select button (

) to START 

(or STOP) 

Will have no effect if the 
External pump is already 
switched on (see above) 
Will not operate if the Internal 
(Fresh) water tank is showing 
100% Full 

Clock Set? 

12:00 

 

 

Access to set the internal clock 
Press the select button (

) to 

select HOUR 
Use the up / down (

▲▼

) buttons to 

change 
Press the select button (

) to 

select MINUTE 
Use the up / down (

▲▼

) buttons to 

change 
Press the select button (

) to exit 

Please note the clock uses a 
24 hour cycle 

Alarm Set? 

12:00 

 

 

Access to set the alarm clock 
Press the select button (

) to 

select HOUR 
Use the up / down (

▲▼

) buttons to 

change 
Press the select button (

) to 

select MINUTE 
Use the up / down (

▲▼

) buttons to 

change 
Press the select button (

) to exit 

Please note the alarm uses a 
24 hour cycle 

Alarm = Off 

 

 

 
 

Shows the alarm clock status (on / 
off) 
Press the select button (

) to 

switch between OFF or ON 

The addition of a asterisk (*) 
in the top left of the main 
EC325 display indicates that 
the alarm is set 

 

Summary of Contents for EC328

Page 1: ...ional components The dual regulator charges both the vehicle and leisure batteries simultaneously Enhanced Digital Control Panel With scrolling menu system battery condition voltage and current water...

Page 2: ...Current Device Miniature Circuit Breakers Residual Current Device RCD Miniature Circuit Breakers MCB s RCD Test button The Residual Current Device RCD is basically provided to protect the user from le...

Page 3: ...re load and the battery with the leisure load taking priority as per the following example Leisure load Available power for battery charging 5A 20A 10A 15A 15A 10A 20A 5A 3 3 Solar Panel Converter The...

Page 4: ...ical batteries are used The battery feed is fitted with an inline fuse between the battery and the electrical harness and is usually located immediately outside the battery compartment or within 500mm...

Page 5: ...ption to a discharge level of 10v This cut off only applies to power drawn from the battery by the leisure equipment that is controlled by the control panel power switch it will not protect the batter...

Page 6: ...ted for approximately 6 seconds after any key press 4 2 Menu Functions Readings section Display Description Options Notes EC328 v2 1H 12 00 23 9 C Main Control Panel display showing model number EC328...

Page 7: ...ste water tank 2 measurement levels If the water pump power switch is turned ON and the waste water level rises to 100 a warning beep will be heard and the LCD display will flash To cancel the warning...

Page 8: ...tank from the external tank Use the select button to START or STOP Will have no effect if the External pump is already switched on see above Will not operate if the Internal Fresh water tank is showin...

Page 9: ...f the main EC325 display indicates that the event timer is set 4 4 Event Timer example The event timer is designed to allow the leisure vehicle user to turn the 12v power on or off in the same way as...

Page 10: ...BS7671 In most cases the site warden will hold information regarding suitability of supply If using a generator you also need to comply with the requirements instructions supplied with the generator...

Page 11: ...n when using my Generator This is a normal side effect when using some types of generator Instead of connecting the neutral conductor to earth some generators centre tap the earth connection making bo...

Page 12: ...ition switch will illuminate Battery not connected and or charged Install charged battery as per 3 7 Power switch on control panel not switched to ON Turn power on at control panel Battery flat Batter...

Page 13: ...tic shutdown and restart if overheated overloaded 6 2 Dimensions Overall size HxWxD 240 x 370 x 110mm Fixing centres 210 x 360mm EC328PSU Clearances 75mm above 20mm below 50mm left right Weight 3 8 Kg...

Page 14: ...ttery input 2 2 BROWN GREEN 3 Battery common earth 2 WHITE ORANGE B Signal Input Connector Pin Function Wire Colour 10 Battery Temp sensor BLACK WHITE 9 Battery Temp sensor BLACK 8 Fresh sensor 75 ful...

Page 15: ...10 BLACK tracer 5 Fans 2 10 BLACK tracer E 230v Mains Input connector Pin Function Wire Colour 1 Live BROWN 2 Earth GREEN YELLOW 3 Neutral BLUE F 230v Mains output connector 2 off connectors wired id...