– 17 –
3. Lens Adjustment
Preparation:
POWER switch: ON
Adjustment condition:
More than A3 size siemens star chart
Fluorescent light illumination with no flicker
Illumination above the subject should be 400 lux
±
10 %.
Adjustment method:
1. Set the siemens star chart 100 cm
±
3 cm so that it be-
comes center of the screen.
2. Double-click on the DscCalDi.exe.
3. Click the “Focus”, and click the “Yes”.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
Adjustment value determination is effectuated using the "STD
AFPOS" and "FOCUS" values.
If FOCUS=focus1, focus2, focus3, focus4, focus5 and the ad-
justment values fulfill the conditions below, they are determined
as within specifications.
Adjustment value determination
1050<=STD_AFPOS<=1240
-40<=focus1<=+40
-50<focus2<+50
-60<=focus3<=+60
-60<=focus4<=+60
-150<=focus5<=+150
4. AWB Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that
nothing appears in any part of the color viewer except the
white section. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the “AWB”, and click the “Yes”.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Adjustment value determination is effectuated using the "AGC",
“WB”, "MS" and "CHECK" values.
If AGC=a1, a2, a3, a4, a5, CHECK=wc0, wc1, wc2 and
MS=MS1, MS2, MS3, MS4, the adjustment values fulfill the
conditions below, they are determined as within specifications.
Adjustment value determination
100<a1<250, 250<a2<450, 450<a3<600,
550<a4<800, 750<a5<1024
wc0=128
±
2, wc1=128
±
2, wc2=130
±
40
1400<=MS1<=2500, 1700<=MS2<=2900
1800<=MS3<=3100, 2300<=MS4<=3600
30<iris<243
Adjustment values other than the above are irrelevant.
DscCalDi
x
OK
Focus Result
STD_AFPOS=1160
FOCUS=-1,-9,-7,5,-53
!
Camera
Siemens
star chart
Camera
Pattern box
(color viewer)
Dsc Calibration
x
OK
AWB Result:
1:
AGC=176,345,513,682,852
3F_AGC=1,2
WB=278,512,648
CHECK=127,128,142
MS=1728,2102, 2260, 2837
0
IRIS=165
Copy