-3-
■
Lamp Replacement
The LAMP REPLACE indicator will light yellow when
the total lamp used time reaches 2000 hours. This is
to indicate that lamp replacement is required.
The total lamp used time is calculated by using the
below expression,
Total lamp used time =
T
eco
+
T
normal
x2
T
eco
: used time in the Eco mode
T
normal
: used time in the Normal mode
You can check the lamp used time following to the
below procedure.
1
Press and hold the
POWER ON-OFF
button on the
projector for more than 20 seconds.
2
The projector used time and lamp used time will be
displayed on the screen briefly as follows.
WARNING:
- For continued safety, replace with a lamp assembly of the same
type.
- Allow the projector to cool for at least 45 minutes before you open
the lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1
Turn off the projector and disconnect the AC cord. Allow the projec-
tor to cool for at least 45 minutes.
2
Loosen 1 screws with a screwdriver and remove the lamp cover.
3
Loosen 2 screws and pull out the lamp assembly by grasping the
handle.
4
Replace the lamp with a new one and tighten the 2 screws back into
position. Make sure that the lamp is set properly. Replace the lamp
cover and tighten the screw.
5
Connect the AC cord to the projector and turn on.
6
Reset the Lamp Replace Counter, see below explanation
.
Note:
- The projector cannot be turned-on with lamp cover removed,
because when the lamp cover is removed, the lamp cover switch is
also released to switch off the lamp circuit.
1
Turn the projector on, press the
MENU
button and the
On-Screen Menu will appear. Press the
Point
Left/Right
button to move the red frame pointer to the
Setting Menu icon.
2
Press the
Point Down
button to move the red frame
pointer to the Lamp counter reset item and then press
the
SELECT
button. The message "Lamp replace
counter Reset?" is displayed.
Move the pointer to
[Yes] and then press the
SELECT
button.
3
Another confirmation dialog box appears and select
[Yes] to reset the Lamp replace counter.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may
result in internal heat build up and short lamp life. We
recommend cleaning the air filter after the projection
lamp is replaced.
Refer to “Air Filter Cleaning”.
Counter
Projector
525H
Lamp
Normal 150H
Eco 375H
Total 675H
How to reset Lamp Replace Counter
How to check Lamp used time
Lamp
Lamp Cover
Screw
Screw
Handle
Screw
Projector used time
ORDER REPLACEMENT LAMP
Type No.
Service Parts No.
POA-LMP55
610 309 2706
Total lamp used time
Summary of Contents for PLC-XU51
Page 32: ...MV7 XU5100 32 Mechanical Parts List L2 Prism LCD panel Ass y L2 c L2 a L2 b L2 e L2 d L2 ...
Page 33: ...MV7 XU5100 33 Mechanical Parts List A D D E B C C L19 L13 L5 L8 L18 L11 L1 L3 L7 L12 L6 L14 ...
Page 35: ...MV7 XU5100 35 ...
Page 36: ... MV7A Aug 2004 BB 400 Printed in Japan SANYO Electric Co Ltd ...