Adjustment Instruction
1
Safety Instructions
1.1 Power supply must be cut off when replacing or welding any component or inserting / pulling out
connective lines;
1.2 Anti-electrostatic measures must be carried out during the whole producing processes!
a) Do not touch IC by hands at will;
b) Use anti-electrostatic iron;
c) Welder must wear anti-electrostatic glove;
1.3 Replacing any component with special safety requirement must refer to component list without
changing its specification and model at will.
2 Adjustment
Equipments
Multimeter or osciillograph
VG-849
CA-21
USB
DVD (included HDMI 1.4) or equipments with the same functions
3 Adjustment
Processes
3.1 Power voltage test
According to the wiring diagram specified by “Product Specification”, connect power board
assembly, data processing assembly, IR/Key board assembly, backlight board assembly correctly,
supply with power, press button
to power on the TV set.
Test voltage of socket X601 each pin on the main board. Voltage value and range are listed as
Table 1:
Table 1 Voltage of X601 each pin
X601 Pin1,2 3,4
5,6
7,8
9 10 11 12 13
Voltage 24V±5% 0
12
V±5%
0
≤
5.2V
5
V±5%
5
V±5%
≤
5.2 V
≤
5.2 V
Function AMP_PWR GND
+5V
STB
GND
PWR_SW
Main
5V
+5V
STB
BL_PWM BL_ON
Summary of Contents for LED-42XR11F
Page 17: ...Speakers Block Diagram ...
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ...Power board ...
Page 31: ...APPENDIX B Exploded view LED 42XR11F ...
Page 36: ...August 2011 ...