20
19
MASSAGING (AUTOMATIC COURSES)
①
Measure the position of shoulder.
②
Starts the massaging of selected course.
Check if the position of shoulder is correct. If not, adjust the position using the POSITION ADJUST button.
(See page 20)
Each time the UPPER BODY STRENGTH ADJUST button is pressed,
the strength of upper body massaging can be adjusted in five stages.
(The strength is displayed by the lamp on the remote control.)
Each time the LOWER BODY STRENGTH ADJUST button is pressed,
the strength of lower body massaging (air) can be adjusted in three stages.
(The strength is displayed by the lamp on the remote control.)
The position of current massage
flickers
Finishes the massaging by the
operation of the timer. (After the
massaging rollers return to the
origin, the lamp on the remote
control will turn off)
Explanation with an example of
NECK/SHOULDER
Displays the aim of massaging positions, the type
of massaging, body pressure and the remaining
massaging time on the remote control.
Massaging neck/shoulder mainly
Massaging operation and display of remote control
5
Starts the massaging automatically.
6
Adjust the strength of massage.
(See page 20)
4
Press the desired Automatic Course button.
■
Finishes the massaging automatically by timer operation.
1
6
4
2
5
3
Massages mainly
the neck and
shoulders.
NECK/SHOULDER
LOWER BACK
Massages mainly
the waist and lower
back.
LOWER BODY
Air massage mainly
on the legs and
soles of the feet.
COMFORT AIR COURSE
Air massage mainly
on the waist and
legs.
Measure the position of shoulder and
match the position of massaging rollers
to that of shoulder.
Measurement of shoulder position
Massaging rollers move up and down
to measure the position of shoulder.
(Sit deeply on the massage chair and raise your
head slightly. The matching of the position of
shoulders may not be possible if the head is
leaning on the back rest.)
Massaging operation at recognized
position of shoulder.
Check that massaging rollers match
the position of your shoulder.
If not, when the lamp of is
flickering (a buzzer sounds),
adjust the position by pressing
the POSITION ADJUST button.
The massaging rollers are
moved up or down by 0.4
"
each time the POSITION
ADJUST button is pressed.
When it is difficult to
adjust with POSITION
ADJUST button, move
your body for adjustment.
The height that can be
adjusted is between
approx. 59
"
to 70.8
"
.
Decides the position of shoulder.
Position too high
Position too low
Appropriate position
Massaging
rollers
(Remote control display)
When the button is pressed, the lamp of the remote
control illuminates and the sole warmer will turn on.
When the foot rest is fully lowered, the foot rest will
rise a little.
When the massaging rollers are not located in the
upper section, the massaging rollers will move to the
upper section and stop. (During the movement, the
characters of "ORIGIN" on the remote control flicker.)
1
Press the OPERATION ON/OFF button.
Sole warmer will be turned on or off each time
the SOLE WARMER button is pressed. (The button is
illuminated while the sole warmer is on.)
If you feel that the sole warmer is too hot, turn it off
by pressing the SOLE WARMER button.
3
Adjust the positions of the back rest and the foot rest.
(See page 13-15)
2
Turn the sole warmer on or off.
*
When the room temperature is low such as in winter,
it takes some time to warm up or you may barely feel warm.
If you have felt abnormal physical sensation or want to stop the massager immediately
To stop the massage during massaging operation.
Press the OPERATION ON/OFF button.
The massaging that corresponds to the pressed
button will stop.
(The Massaging rollers will stop at that point.)
All the massaging will stop and the chair will be
automatically brought to its home position.
(The massaging rollers are moved to the upper
position and remain in that position.)
Press the INSTANT STOP button.
All the massaging will stop and the lamp of the remote control
will turn off.
When you want to restart massaging, press the OPERATION
ON/OFF button. (The massaging rollers move to the upper
position and remain in that position.)
After the movement, repeat the operation from the beginning
of each massage.
Press the button for the current operation.
Lower Body can be operated simultaneously with Neck/Shoulder or Waist.
Air Course cannot be operated simultaneously with any other courses.
Refer to the page 28 regarding the massaging contents of Automatic Course.
Change of course during massaging, or change to the
Whole Body Sensor
Automatic Course
or the Manual Course, is possible.
The massaging rollers are moved to the upper position and are stopped automatically approx. 15 minutes
after starting the operation. The buzzer sounds and the lamp on the remote control will turn off.
Adjusting the strength of massage
When it is felt that the massaging on the soles or calves is too strong even when reducing
the strength of lower body (air) massaging, put a towel etc. on those massaged parts.
NOTE