background image

PRECAUTIONS

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE
TO EXCESSIVE MICROWAVE ENERGY

(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other

microwave source, and make repairs as necessary:

(1) Interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage),

(4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.

(c) Before turning on microwave power for any service test or inspection within the microwave generating

compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity,

and connections.

(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and

transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before

the oven is released to the owner.

REFERENCE NO. SS-860264

Foreword

Read this manual carefully, especially precaution on microwave energy, and follow the procedure strictly.

Careless servicing and testing may expose yourself to the microwave energy leakage.

File No :

 SUPPLEMENT OF

Microwave Oven EM-X471S

 

SERVICE MANUAL

EM-X471YS
EM-X471US

EM-X471SS

EM-X471BS 

(Australia / New Zealand)

Model No :

Product Code No :

EM-X471S

437 450 47

EM-X471YS

437 450 48

EM-X471US

437 450 49

EM-X471SS

437 450 50

EM-X471BS

437 450 54

See the Service Manual of EM-X670S (SM-860177)

except the items described in this Service Manual.

Summary of Contents for EM-X471BS

Page 1: ...mission line and cavity for proper alignment integrity and connections d Any defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is released to the owner REFERENCE NO SS 860264 Foreword Read this manual carefully especially precaution on...

Page 2: ...PECIFICATIONS Rated Power Consumption 1500W Microwave Output 1000W Frequency 2 450MHz 50MHz Power Supply 230 240V 50Hz Rated Current 6 6 Amp Safety Devices Temp Fuse open at 167o C for Cavity Thermal Protector open at 122o C for Magnetron Fuse Cartridge Type 8A Primary Interlock Switch Door Sensing Switch and Relay 2 Interlock Monitor Switch Timer Electronic Digital up to 99 min 99 sec Overall Dim...

Page 3: ...GE Y YELLOW R RED NOTE THE SIGN Parts marked with this sign are supplied with High Voltage exceeding 250V THE SIGN Parts marked with this sign have special characteristics important for microwave leakage When replacing any of these parts use only manufacturer s specified parts ...

Page 4: ... each filament Normal reading terminal of the Magnetron and the chassis Infinite Ohms ground with an Ohm Meter on highest scale 1 Measure the resistance Normal readings With an Ohm Meter on R x 1 scale a Primary winding Approximately 1 53 Ohms b Filament winding Less than 1 Ohm c Secondary winding Approximately 97 2 Ohms 2 Measure the resistance Normal readings With an Ohm Meter on highest scale a...

Page 5: ...OTE When reconnecting the FPC connector make When checking START key connect sure the holes on the connector are properly Ohm Meter as illustration below inserted in hooks of the plastic fastener in S101 MATRIX CIRCUIT FOR TOUCH KEY BOARD FPC CONNECTOR Figure 6 Ohm Meter TERMINALS OF FPC CONNECTOR TOUCH KEY BOARD 4 CONTROL CIRCUIT BOARD 0 6 5 1 2 3 4 7 8 9 STOP CLEAR POWER LEVEL FINE DEFROST QUICK...

Page 6: ...rt No Description Q ty No 11 411 011 0802 Bolt Hex SW W 5 x 14 Z1 2 12 617 180 6137 Hinge Lower 1 13 411 089 2500 Washer F5 x 10 x 0 8 1 14 617 120 8481 Insulation Sheet 1 15 617 144 4476 Turn Table Shaft 1 16 617 204 9489 Roller Base Assy 1 17 617 073 5889 Rotating Tray 1 18 617 222 2912 Antenna Complete 1 19 617 162 1938 Cavity Cover 1 20 411 069 1707 SCR TPG TRS 4 x 6 DA 1 21 411 006 6604 SCR T...

Page 7: ...604 SCR TPG PAN 3 x 6 Z1 1 5 617 124 1235 Thermostat Magnetron 122o C 1 6 415 002 6101 Magnetron 2M219H B A 1 7 423 022 7503 Fuse 250V 8A 1 8 617 213 3416 Power PCB 1 9 617 225 8553 Lead Wire Ass y with Diode 1 10 617 162 1990 Space Partition Blower 1 11 617 212 9013 H V Capacitor including Resistor 1 1 10µf 2 5KV 12 617 182 2373 Capacitor Band 1 13 411 011 5609 Bolt Hex 4 x 10 Z1 4 14 617 198 499...

Page 8: ...7 6294 Door Cover EM X471S 1 1 617 224 2286 Door Cover EM X471YS 1 1 617 224 2149 Door Cover EM X471US 1 1 617 224 4105 Door Cover EM X471SS 1 1 617 210 7271 Door Cover EM X471BS 1 2 617 210 7592 Door Panel 1 3 617 205 7163 Door Main Frame Also order 1 Door Sheet when replacing Door Main Frame 7 DOOR PARTS ALL SERVICE ON MICROWAVE OVENS SHOULD BE PERFORMED BY A QUALIFIED TECHNICIAN USING APPROVED ...

Page 9: ...elease Lever EM X471YS 1 9 617 224 2187 Door Release Lever EM X471US 1 9 617 224 4136 Door Release Lever EM X471SS 1 9 617 210 7288 Door Release Lever EM X471BS 1 Key Part No Description Q ty No 1 617 225 6054 Control Sheet EM X471S 1 1 617 225 8423 Control Sheet EM X471YS 1 1 617 225 8430 Control Sheet EM X471US 1 1 617 225 8447 Control Sheet EM X471SS 1 1 617 225 9963 Control Sheet EM X471BS 1 2...

Page 10: ... 9 CONTROL CIRCUIT BOARD Part No 617 222 7016 35500 ...

Page 11: ...17 128 3372 Ceramic Oscillator 1 S1 617 169 4109 Connector 1 S101 617 126 8959 Connector 11P 1 S201 617 002 4396 Connector 3P Male 1 S102 617 111 1392 Connector 2 3P Male 1 PT1 617 171 2155 Step Down Trans 1 PD5TK S150 2 617 079 4107 Spacer 1 J1 6 617 079 4299 Jumper 6 J101 108 617 079 4237 Jumper 8 10 CONTROL CIRCUIT BOARD Part No 617 222 7016 Key No Order Part No Description Q ty INTEGRATED CIRC...

Page 12: ... 11 6 OVERALL CIRCUIT DIAGRAM SANYO Electric Co Ltd Osaka Japan July 99 300 LT Printed in Singapore ...

Page 13: ......