background image

 
 
 
 
 
 
 

BASIC SERIAL COMMAND FUNCTIONAL 

SPECIFICATIONS

 

 

32LM4R / 32LM4WPR 
42LM4R / 42LM4WPR 

 

2006/09/05 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

SANYO Electric Co.,Ltd 
AV Company 
TV Development Business Unit

Summary of Contents for CE42LM4N-NA - CE - 42" LCD Flat Panel Display

Page 1: ...BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS 32LM4R 32LM4WPR 42LM4R 42LM4WPR 2006 09 05 SANYO Electric Co Ltd AV Company TV Development Business Unit ...

Page 2: ...mmand 8 6 10 Wide Title in 16 9 direct Command 9 6 11 Wide Zoom 14 9 direct Command 9 6 12 Wide Title in 14 9 direct Command 9 6 13 Wide Full direct Command 9 6 14 Wide Normal direct Command 9 6 15 Pcicture mode Command 10 6 16 AV1 direct Command 10 6 17 RGB direct Command 10 6 18 AV2 RGBHV direct Command 10 6 19 AV2 YPbPr direct Command 10 6 20 AV3 direct Command 10 6 21 HDMI direct Command 11 6 ...

Page 3: ...mand 14 7 6 Wide Mode Read Command 14 7 7 Signal status Read Command 15 7 8 Child lock setting Read Command 15 7 9 Power save setting Read Command 15 7 10 Panel usage time Read Command 15 7 11 RC Inhibition Read Command 15 8 Addressing Format command 16 8 1 overview 16 8 2 Functional execution command with address 16 8 3 Status Read command with address 17 ...

Page 4: ...n Transfer Specification Item Specification Synchronous system Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity None Stop Bit 1 Flow Control None Transmission speed initial setting value is 19200 Transmission speed can be changed in hotel option menu Connection Dedicated serial cable that comes with the TV must be used for a connection to a computer and TV PC TV COM 1 Control Po...

Page 5: ...d the first data C it clears the information of buffer 3 4 For the command pipelining wait interval of 100 ms after the response More than 100ms Command PC TV C 0 7 CR Next Command TV PC ACK CR Carriage Return a few ms 5s 3 4 1 When a command is issued before receiving response the function is not executed properly 3 4 2 Except when there is no response for 5 seconds 3 5 It takes about 5 seconds f...

Page 6: ...14 9 direct C29 Wide Full direct C0F Wide Normal direct C30 Picture Toggle Dynamic Standard Eco Personal C70 AV1 direct C71 RGB direct C72 AV2 RGBHV direct C73 AV2 YPbPr direct C74 AV3 direct C75 HDMI direct C76 PC direct C64 PC Auto adjust C92 Factory setting CF PSAVE ON Power save ON CF PSAVE OFF Power save OFF CF CLOK ON Child lock ON CF CLOK OFF Child lock OFF CF DEA RMCY RC inhibition OFF CF ...

Page 7: ...wer error CR1 Input Mode AV1 AV2 HDMI PC CR WIDE Wide mode Auto Normal Full CR PICTURE Picture mode Dynamic Standard CR SIGNAL Signal existence Signal No signal CR CHILD Child lock On Off CR PSAVE Power save On Off CRTM Panel usage time CR RMC RC inhibition On Off means No Function ...

Page 8: ...he command pipelining the performance is the same as the remote control s performance 1 System issue any commands every 100 ms after receiving response 2 When receiving the appropriate command the function is executed for 120 ms from the moment 3 When receiving the same command continuously within 120 ms the function is executed for another 120 ms from the moment 4 When there is no incoming comman...

Page 9: ...Detail Power OFF Standby When already standby mode no operation is necessary Response Acceptable ACK CR Unacceptable CR 6 7 Wide Auto direct Command Command C23 CR Detail Set wide mode to Auto directly When PC mode or AV2 RGBHV mode no operation is necessary Response Acceptable ACK CR Unacceptable CR 6 8 Wide Natural direct Command Command C24 CR Detail Set wide mode to Natural directly When PC mo...

Page 10: ... Acceptable ACK CR Unacceptable CR 6 12 Wide Title in 14 9 direct Command Command C28 CR Detail Set wide mode to Title in 14 9 directly When PC mode or AV2 RGBHV mode no operation is necessary Response Acceptable ACK CR Unacceptable CR 6 13 Wide Full direct Command Command C29 CR Detail Set wide mode to Full directly This works even in PC or AV2 RGBHV mode Response Acceptable ACK CR Unacceptable C...

Page 11: ... 17 RGB direct Command C71 CR Detail Select RGB mode directly Response Acceptable ACK CR Unacceptable CR 6 18 AV2 RGBHV direct Command Command C72 CR Detail Select AV2 RGBHV mode directly Response Acceptable ACK CR Unacceptable CR 6 19 AV2 YPbPr direct Command Command C73 CR Detail Select AV2 YPbPr mode directly Response Acceptable ACK CR Unacceptable CR 6 20 AV3 direct Command Command C74 CR Deta...

Page 12: ...sponse Acceptable ACK CR Unacceptable CR 6 24 Factory setting Command Command C92 CR Detail Execute Shipping condition function Response Acceptable ACK CR Unacceptable CR 6 25 POWER SAVE ON Command Command CF PSAVE ON CR Detail Set PSAVE to ON Response Acceptable ACK CR Unacceptable CR 6 26 POWER SAVE OFF Command Command CF PSAVE OFF CR Detail Set PSAVE to OFF Response Acceptable ACK CR Unacceptab...

Page 13: ...sponse Acceptable ACK CR Unacceptable CR 6 29 RC Inhibition OFF Command Command CF DEA RMCY CR Detail Set RC inhibition to OFF Response Acceptable ACK CR Unacceptable CR 6 30 RC Inhibition ON Command Command CF DEA RMCN CR Detail Set RC inhibition to ON Response Acceptable ACK CR Unacceptable CR ...

Page 14: ... is appropriate the TV returns a character line as the required data Required Data CR TV Æ PC Required Data A character line See Status Read Command Table 7 1 3 When the received command is not appropriate the TV returns to PC CR TV Æ PC 7 2 Transfer Example Get input mode for TV by Basic Commands Command issues current input mode command PC TV C R 1 CR TV PC 1 CR Response A few ms 1s Showing Comp...

Page 15: ...YPbPr AV3 AV3 HDMI HDMI PC PC RF RF Unacceptable CR 7 5 Picture mode Read Command Command CR PICTURE CR Detail Get the picture mode Response Acceptable 1 CR 1 000 Personal Personal 000 Dynamic Dynamic 000 Eco Eco 000 Standard Standard Unacceptable 1 CR 7 6 Wide mode Read Command Command CR WIDE CR Detail Get the wide mode Response Acceptable 1 CR 1 000 Auto Auto 000 Natural Natural 000 Zoom 16 9 Z...

Page 16: ...ptable 1 CR 7 9 Power save setting Read Command Command CR PSAVE CR Detail Get the PSAVE setting Response Acceptable 1 CR 1 000 OFF OFF 000 ON ON Unacceptable 1 CR 7 10 Panel usage time Read Command Command CRTM CR Detail Get the Panel Usage Time Response Acceptable 1 CR 1 Panal Usage Time in hour by 5 digits Ex 00123 This means 123 hours Unacceptable CR 7 11 RC inhibition Read Command Command CR ...

Page 17: ...e set in the range of 001 to 999 Default address is 001 The TV clears the information of receiving buffer and the function is not executed when the following condition occurs 1 When it takes more than one second until the TV receives carriage return since it has received the first data C and or 2 When LF 0x0A or EOF 0x1A is received 8 2 Functional execution command with address 8 2 1 Format 1 PC i...

Page 18: ...A Address CR_ Command CR PC Æ TV Address 3 digit number 001 to 999 Command See Status Read Command Table _ means space 2 Only TV with which address matches responds The TV returns required data or to PC Required Data CR TV Æ PC Required Data A character line See Status Read Command Table CR TV Æ PC When received command is not appropriate ...

Page 19: ...Ver Page 18 PROTECTION SHEET ...