SY75C Excavator OMM
Maintenance Procedures
SANY
Operation and Maintenance Manual — 0220
5-45
TABLE OF
CON
T
ENT
S
INT
R
ODUCT
ION
SA
FETY
MA
C
H
INE
CONTROLS
MA
C
H
INE
OPERA
T
ION
MAINTENAN
C
E
SPECIFICA
T
IONS
OP
T
ION
AL
EQUIPMENT
6. Replace the O-ring on all removed plugs.
7. Reinstall and tighten both plugs.
8. Check for external leaks.
Collect Final Drive Oil Sample
1. Obtain an Oil Analysis Sample Kit from a SANY dealer.
2. Operate the machine to normal operating temperature.
3. Prepare the machine for service.
4. Remove the final drive check plug. See “Final Drive Gearbox Oil Level - Check” on page 5-44.
5. Insert the oil sample tube into the final drive and collect a sample of final drive oil. Install the final drive check
plug.
6. Send the sample for testing in accordance with the instructions packaged with the sample kit.
Final Drive Motor Mounting Bolts - Check
1. Locate final drive motor (a) on one of the track
assemblies.
NOTICE!
If oil leaks are found during the oil level inspection, stop the inspection, locate and repair the
cause of the oil leaks. Failure to avoid doing this could result in machine damage and
improper machine operation.
NOTICE!
It is critical that all material used to collect the sample is absolutely clean. Failure to adhere to
this warning can cause equipment damage and contaminate the sample.
Fig. 5-59
a
Summary of Contents for SY75
Page 2: ......