Maintenance
SY215C LC/SY225C LC Excavator OMM
5-42
Operation and Maintenance Manual — 1219
SANY
Check the Engine Air Filter System
1. Prepare the machine for service. See “Maintenance
2. Locate the air filter housing behind the left front door.
3. Squeeze the dust evacuator (2) mounted on the end cap
of the filter housing (1) to release any dust or debris.
4. Check the condition of the dust evacuator and replace if
required.
NOTE:
If the dust evacuator is cracked, torn, remains
open, or is missing, dust particles that are
normally expelled can collect on the air filter
and shorten the air filter service life.
Fig. 5-39
2
1