Quick Instructions

Photos illustrating products are non contractual.

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in this manual before using the product. Failure to 

comply with these instructions may result in personal injuries or damage to the unit or system.

1. Never expose eyes or skin to ultraviolet light from any source. Therefore, before installing or 

performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system 

from all power sources (there may be more than one switch to disconnect).

 

 CAUTION: Electrical shock may cause personal injuries or possibly death.

2. When installing or performing maintenance on the UV unit or system, it is recommended to wear 

safety glasses and gloves. In order to avoid reduced performance of lamp(s), do not touch lamp 

glass without gloves.

3. UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV 

lamps can be disposed/recycled after use, as any other fluorescent lamps. Contact and follow your 

local and national authorities’ specific instructions.

4. 

Use only specified SANUVOX branded replacement UV lamps with your unit or system.

 Use of 

any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

5. UV rays may destroy certain types of filters (polymer or plastic); please keep the unit or system light 

away from shining directly on plastic.

FOR COMPLETE INSTRUCTION MANUAL, 

VISIT THE PRODUCT PAGE ON 

WWW.SANUVOX.COM

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

SETUP & INSTALLATION

What you will need

Utility knife, scissors, Phillips No.2 screwdriver, 9 mm or 11/32" wrench.

 CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, install 

and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit or system 

label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.

What’s included

The S300 MED2, a MERV9 prefilter, a HEPA filter, a UV GX lamp, castors (4), long 8-32 screws (4), short 8-32 screws (4), 8-32 nuts 

(8), the access door for the lamp (white metal plate) and a basic installation kit.

The installation kit includes: a pair of cotton gloves, a 3-prong power cord (6') and self tapping 8/32 x 1/2 screws for the front plate (6).

Step by Step Setup & Installation

1. 

Take your unit out of the packaging and place it upside down so that you can access the bottom of the unit.

2. 

Open the filter and motor access door

 of your S300 unit: this is the large square door closed by the big black clamp.

3. 

Install your unit castors:

 temporarily lift the foam to reach inside the unit and screw the front castors first. Screw the (2) front 

castors with (4) long 8-32 screws and (4) 8-32 nuts per castor. Use a 9 mm or 11/32" wrench and Phillips No.2 screwdriver.

4. 

Then, in the same way, screw the (2) back castors with (4) short 8-32 screws and (4) 8-32 nuts per castor.

 

With the castors now installed, remove the masking tape from the castors and turn your unit right side up.

5. 

Check the filters (2):

 If they are covered with plastic wrap, be sure to unpack them before continuing.

6. 

Under the HEPA filter is the cardboard sleeve containing the UV lamp. 

Carefully slide the UV lamp out from the cardboard 

sleeve.

 Be sure to wear the cotton gloves (included) ensuring the lamp is free from fingerprints.

 

NOTE: Fingerprints on the lamp will negatively impact the UV output of the lamp.

7. 

While holding the UV lamp by its porcelain end-cap, slide it into the rectangular opening in the back of the unit (above the filter 

and motor access door).

8. 

Carefully push the white connector onto the four pins. The plug is designed so it can only be installed one way. You may have to 

rotate the socket 90° to line up the pins with the holes. The connector will fit into position.

 

NOTE: Too much force applied from the opposite end-cap may break the lamp.

9. 

Then, slide the porcelain tip through the retention clamp.

 NOTE: 

Make sure the lamp is horizontal in this section and not touching the metal walls.

10.  Take the access door for the lamp from the supplied accessories and position it over the rectangular opening. Secure the 

plate in place with the 6 screws provided for this purpose.

11. 

Close the filter and motor access door 

of your S300 unit.

12.  Roll your unit in place and always leave a 2" minimum clearance space between the unit front (where the air inlet and outlet are) 

and any wall. Make sure you have a power outlet nearby to plug the unit into.

Your new S300 MED2 is now ready to operate.

S300 MED2

HEPA & UV AIR 

DISINFECTION UNIT

Medical Model