USER AND MAINTENANCE MANUAL 

SANTOS

 SAS: 

140-150 AVENUE ROGER SALENGRO 
69120 VAULX-EN-VELIN (LYON) - FRANCE 
TÉL. 33 (0) 472 37 35 29 - FAX 33 (0) 478 26 58 21 -  
TELECOPIE 33 (0) 478 26 58 21 
E-Mail :[email protected]       

www.santos.fr

AUTOMATIC SILENT ESPRESSO COFFEE GRINDER  

#40A-40A PPM / #06-06A

 

 

IMPORTANT: documents included in this manual to be kept: 

 

"CE" COMPLIANCE DECLARATION  

 

WARRANTY CERTIFICATE 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Model #40A – 40A PPM  

Model #06 – 06A 

 

 

Coffee grinders - Fruit juicers - Mixers - Blenders - Drinks dispensers - Planetary mixers 
Cheese graters - Ice crushers - Mincers - Vegetable slicers – Dough mixer 
Moulins à café - Presse-fruits - Mixers - Blenders - Distributeurs de boissons - Batteurs 
mélangeurs - Pétrin - Râpes à fromage - Broyeurs à glaçons - Hache-viande - Coupe-légumes

 

 

MODELES DEPOSES FRANCE ET INTERNATIONAL 

INTERNATIONALLY PATENTED MODELS 

Summary of Contents for 06 - 06A

Page 1: ...R 40A 40A PPM 06 06A IMPORTANT documents included in this manual to be kept CE COMPLIANCE DECLARATION WARRANTY CERTIFICATE Model 40A 40A PPM Model 06 06A Coffee grinders Fruit juicers Mixers Blenders...

Page 2: ...stones 8 FAULT FINDING 10 The machine will not start 10 The machine stops as a result of motor over heating the motor unit is hot 10 The machine stops as a result of an overload 10 The machine stops a...

Page 3: ...ROVISIONS OF THE FOLLOWING EUROPEAN DIRECTIVES No 73 23 dated 19 02 73 Low voltage directive No 89 336 CEM directive No 2002 95 CE RoHS directive No 2002 96 CE WEEE directive The machine complies with...

Page 4: ...Unplug the appliance before carrying out any work on it cleaning maintenance or repair 8 The use of spare parts other than certified SANTOS original parts is prohibited ELECTRICAL CONNECTION The elect...

Page 5: ...s from electrical and electronic equipment It signifies that this product should be taken over by a selective collection system conforming to the Guideline 2002 96 EC WEEE part Professional Equipment...

Page 6: ...bly and preparation fig A 1 Model 40A Clip the ground coffee collector 3 onto the base 4 2 Put the dose measurer lid 24 in place 3 Put the bean container 2 in place on the grinder body adjustment nut...

Page 7: ...ease the indexing pointer 7 to retain the grinding adjustment 5 Draw off a few measures of coffee to check the grinding adjustment Depending on the type of coffee used and the fineness of grinding req...

Page 8: ...ine in the middle of the base plate fig E Pull the electrical components unit 20 out of the base plate Using a screwdriver with an insulated handle touch the 2 capacitor connections 15 The sight of an...

Page 9: ...ll coffee particle under the grindstone may prevent the machine from operating correctly It is recommended that the grinder body is cleaned with a compressed air jet or a dry brush CARE do not unscrew...

Page 10: ...e unit 19 fig M Check the electric components replacing them one by one The machine stops as a result of motor over heating the motor unit is hot The motor is protected by an integral thermal protecti...

Page 11: ...e dose measurer The ground coffee jams in the grinder body conduit The machine has perhaps been subjected to a vertical blow e g during transport remove the dose measurer and check that the seal betwe...

Page 12: ...x g From 5 5 to 9 5 Dose measurer capacity kg 0 2 Automatic start and stop 40A 40A PPM 06A only Every 3 to 5 measures Dimensions Height mm 580 570 Width mm 190 230 Depth mm 390 250 Weight Net weight k...

Page 13: ...V 50 60Hz wiring diagram On Off White White Amperometric protection White Black Green Yellow White 4 3 2 Start relay White Capacitor Yellow White Brown Red Red M Black Dose measurer safety device Blue...

Page 14: ...iring diagram 4 3 2 Start relay Black M White On Off White 180 White 240 White 240 Orange Amperometric protection Green Yellow Violet 200 Brown 600 Capacitor Orange Dose measurer safety device 1x240 1...

Page 15: ...g diagram On Off Red Green Yellow Violet 200 Brown 600 1x240 1x350 White 240 White 240 Amperometric protection 4 3 2 Start relay Blue Capacitor Yellow White Black Grey White 180 Red M Dose measurer sa...

Page 16: ...sure adjustment thumb wheel 9 Grindstone 10 Power supply lead plug 11 On Off switch 12 Graduated plate 13 Excess current protection 14 Start relay 15 Capacitor 16 Identification plate 17 Motor spindle...

Page 17: ...SANTOS User and maintenance manual Figures 19 11 22 20 21 4 7 5 24 6 2 1 Fig A 24 20 19 22 21 10 11 5 6 4 3 2 1 98140 US 3 0 05 2007 17 20 www santos fr...

Page 18: ...SANTOS User and maintenance manual 5 7 Fig C Fig B 20 23 21 3 22 Fig A 24 20 19 22 21 10 11 5 6 4 3 2 1 Fig D 8 98140 US 3 0 05 2007 18 20 www santos fr Fig F 9 9 Fig E 14 13 15 20 16 Fig G 6...

Page 19: ...SANTOS User and maintenance manual 98140 US 3 0 05 2007 19 20 www santos fr Fig K 5 7 Fig J 18 17 Fig I Meule mobile Meule fixe Fig H 5 7 Fig L 12 5 7 Fig O 13 Fig N 20 Fig M 19...

Page 20: ...ompanied by a copy of this warranty certificate on which the serial number of the appliance is shown All appliances have an identification plate bearing a serial number identical to that on this warra...