![Santerno SUNWAY TG1200 1000V TE OD Installation Manual Download Page 132](http://html1.mh-extra.com/html/santerno/sunway-tg1200-1000v-te-od/sunway-tg1200-1000v-te-od_installation-manual_810313132.webp)
MODULAR SUNWAY TG
TE OD
INSTALLATION GUIDE
132/
139
Rev. 03
– 01/06//2018
No.
Name
Description
I/O Features
DIP-switch
27
MDO2
Digital output
Please refer to the Electrical and
Mechanical diagram
Isolated digital output;
open collector type;
Vomax = 48 V
Iomax = 50 mA
28
CMDO2
MDO2 common digital output
MDO2 common digital
output
29
MDO3-NC
Digital relay output 3 (NC contact)
Please refer to the Electrical and
Mechanical diagram
Switch contact: with low
level logic the common
terminal is closed with
NC terminal, with high
level logic common
terminal is closed with
NO
Vomax = 250 Vac
Iomax = 3 A
Vomax = 30 Vdc
Iomax = 3 A
30
MDO3-C
Digital relay output 3 (common)
Please refer to the Electrical and
Mechanical diagram
31
MDO3-NO
Digital relay output 3 (NO contact)
Please refer to the Electrical and
Mechanical diagram
32
MDO4-NC
Multifunction digital relay output 4 (NC
contact)
Please refer to the Electrical and
Mechanical diagram
33
MDO4-C
Multifunction digital relay output 4
(common)
Please refer to the Electrical and
Mechanical diagram
34
MDO4-NO
Multifunction digital relay output 4 (NO
contact)
Please refer to the Electrical and
Mechanical diagram
Table 55: Terminals 14 - 34 available on the control board
12.12. Environmental sensors and field I/Os expansion board
12.12.1. List of signals to terminal board
Screw terminal board with 12 separate removable sections suitable for 0.08 - 1.5 mm
2
(AWG 28-16) cables.
No.
Name
Description
I/O Features
DIP-switch
1-2
NOT USED
– DO NOT
CONNECT
3
CMA
Analogue inputs 0 V (common
with control 0V)
0V control board
4-5
+15VM-
15VM
Stabilized bipolar power supply
output protected against short-
circuit by external sensors
+15 V
-15 V
Iout max: 100 mA
6
CMA
Analogue inputs 0 V (common
with control 0V)
0V control board