GUIDE TO THE
REGENERATIVE APPLICATION
SINUS PENTA
57/
150
3.9.14.
Regenerative Reactor Ratings
3.9.14.1.
Class 2T and 4T
To use the following table, refer to Figure 8.
ES PART
No.
INDUCTANCE
RATINGS
LOSSES
at Inom TYPE
SIZE
SLOT WEIGHT
TERMINAL
TYPE
CABLE
SECT.
mH
A
W
L P H M X Y
E
G
mm
kg
mm
2
IM0128004
5.2
12.5
70
B
240 140 245 80
-
- 200 87
7x14
16
Cable Lug
hole 8mm
2.5
IM0128044
3.9
16.5
90
B
240 150 245 80
-
- 200 87
7x14
17
Cable Lug
hole 8mm
4
IM0128084
2.2
30
150
B
240 170 250 80
-
- 200 97
7x14
22
Cable Lug
hole 8mm
10
IM0128124
1.8
41
215
B
240 200 250 80
-
- 200 122 7x14
29
Cable Lug
hole 8mm
10
IM0128144
1.2
60
285
B
240 200 250 80
-
- 200 122 7x14
31
Cable Lug
hole 8mm
25
IM0128164
0.90
80
335
B
300 200 320 100 -
- 250 111 9x24
40
Cable Lug
hole 8mm
25
IM0128204
0.70
103
515
B
360 200 345 120 -
- 325 136 9x24
53
Cable Lug
hole 8mm
50
IM0128244
0.50
135
580
C
360 240 350 120 -
- 325 147 9x24
64
Cable Lug
hole 8mm
50
IM0128284
0.35
200
810
C
360 270 410 120 -
- 250 200
hole
12
94
Cable Lug
hole 8mm
120
IM0128324
0.27
320
1080
A
420 300 500 140 405 95 300 200
hole
12
157
Bar 30mm
hole 11mm
240
IM0128334
0.20
440
1950
A
480 320 510 170 430 110 300 250 12x24
203
Bar 40mm
hole 11mm
2x120
IM0128364
0.15
565
1650
A
540 340 550 170 440 125 350 250
hole
12
237
Bar 40mm
hole 11mm
2x185
IM0128374
0.12
700
2870
A
595 360 660 195 540 150 400 300 15x30
332
Bar 50mm
hole 11mm
2x240
IM0128404
0.11
900
2500
A
600 415 660 195 540 150 400 300 15x25
438
Bar 50mm
2 fori 11mm
3x240
IM0128444
0.08
1200
3100
A
675 440 735 215 590 205 450 300 15x25
605
Bar 50mm
2 fori 11mm
4x240
Table 1: Regenerative reactors (class 2T and 4T)
NOTE
For the technical specifications of the UR reactors, please contact
Elettronica Santerno