User manual
SNVR-1412P, SNVR-1812P
_________________________________________________________________________________
- 45 -
7.5.3.2
Main menu
Setting
Event
Alarm
Here you can define the type of alarm to be triggered at the recorder or the camera.
IPC ext. alarm:
This function relates to the physical alarm inputs at the camera.
Requirements for this function are that the camera is equipped with alarm inputs and that at
least one external alarm device is connected to the camera.
Select the camera channel.
Define the type of action (e.g. send e-mail, buzzer, etc.) if the alarm device which is
connected to the camera detects an alarm.
IPC off. alarm:
This function relates to the camera which is offline due to an event. This means that if the
camera is disconnected from power or disconnected from the network (e.g. caused by a
defective cable or manipulation), you can define the type of triggered actions (send e-mail,
buzzer, etc.).
Local alarm:
This function relates to the physical alarm inputs at the recorder. This recorder is equipped
with 4 alarm inputs. Requirements for this function are that at least one external alarm device
is connected to the recorder.