3. Specifications

Part Number:

 4032230

Blower:

 

 257 CFM @ 0.0" WG 
206 CFM @ 0.2" WG 
146 CFM @ 0.4" WG

Power:

 

530 Watts @ 80°F and 60% RH

Supply Voltage:

 

115 volt – 1phase – 60 Hz

Current Draw:

 

4.9 AMPS

Energy Factor: 

 

4.2 L/kWh

Operating Temp.:

  56°F Min., 95°F Max.

Sized for: 

2,500 Sq. Ft. - Typical

Minimum Performance at 80°F and 60% RH

Water Removal: 

105 Pints/Day

Efficiency: 

8.8 Pints/kWh

Air Filter:

 

MERV-11

Size: 

16" x 20" x 2"

Power Cord:

 

10', 110-120 VAC, Ground

Drain Connection:

  

3/4" Threaded NPT

Dimensions 

Unit

 

Shipping

Width: 

20.25" 

24"

Height: 

21.75" 

28.25"

Length: 

38" 

42"

Weight: 

140 lbs 

160 lbs

4. Installation

4.1 Location

The Santa Fe Impact can be installed in a variety of  
locations to meet the owner’s needs; other considerations 
include: 

1.  Providing access to a 115 VAC power outlet   

(10' power cord is provided).

2.  Locating near a floor or other suitable drain  

(8' drain hose included).

3.  Mount 4" above drain.

4.  Do not install the Santa Fe Impact with the exhaust 

of the unit within 1' of a wall or obstruction. Do not 
place the unit near open water.

4.1A No Ducting (fig. 1) 

The simplest installation is to place the Santa Fe Impact with 
no ducting. To ensure optimal performance, the air inlet and 
the outlet of the unit must be at least 2' from walls and other 
obstructions to air flow. Recirculation of outlet air into inlet 
should be avoided as much as possible.

4.1B Ducted Return and Supply (fig. 2) 

Dehumidification performance can be modified by adding an 
return and/or supply duct to circulate air.

For optimal drying, use return duct to draw warm, moist air 
from near the ceiling.

 
4.1C Remote Area, w/ Ducted Supply (fig. 3) 

A simplified remote installation method than above uses 
ducting between the Santa Fe Impact discharge and the humid 
room; the Santa Fe Impact inlet draws air from the room in 
which it’s located. This works well if there is an adequate air 
flow path between the two rooms; e.g. high door undercut, 

Santa Fe Impact XT OWNER’S AND INSTALLER’S MANUAL

3

Santa Fe Impact Installer’s & Owner’s Manual

Input of 

Humid Air

Output of

Dehumidified Air 

Front View

Input of

Humid Air 

Front View

Output of Dehumidified Air 

Front View

Summary of Contents for IMPACT XT

Page 1: ...oducts com Free standing Moisture Control for Large Areas n High capacity n High efficiency n Environmentally friendly n Patent pending dual air distribution INSTALLER S OWNER S MANUAL P N 4032230 Ser...

Page 2: ...ile it is plugged in Do not sit or stand on the unit or use as a shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play wit...

Page 3: ...of a wall or obstruction Do not place the unit near open water 4 1A No Ducting fig 1 The simplest installation is to place the Santa Fe Impact with no ducting To ensure optimal performance the air inl...

Page 4: ...r proper drainage the unit must be mounted so the drain outlet is at least 4 above the floor drain and must be fully supported under the base 4 3 Condensate Water Removal Condensate drains by gravity...

Page 5: ...ta Fe Impact ships with a standard MERV 11 efficient pleated fabric filter This should be checked every six months The pleated fabric filter can generally be vacuumed clean several times before needin...

Page 6: ...ch AUTO but compressor cycles on off 1 Low ambient temperature and or humidity causing unit to cycle through defrost mode 2 Defrost thermostat defective 3 Defective compressor overload 4 Defective com...

Page 7: ...the factory mounted humidity control on the cabinet of the dehumidifier and allows you to accurately sense the humidity in an area other than the one where the dehumidifier is located Santa Fe Impact...

Page 8: ...s to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further con...

Page 9: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680...

Reviews: