Santa Fe Impact Installation & Operation Instructions

Items Included in Box:

• Santa Fe Impact Dehumidifier
• Santa Fe Impact Installation & Operation Instructions
• Santa Fe Impact Leveling Feet
• 8' Drain Hose

Important Precautions

•  Do not install the Santa Fe Impact with the intake or exhaust of the unit within 1' of a wall or other obstruction. Avoid directing 

the discharge air at people. The dehumidifier should be used in the upright position.

•  Do not place the unit where curtains or debris can be drawn into the intake and restrict airflow. 
•  The device is designed to be installed indoors in a space that is protected from rain and flooding. 
•  Do not operate in standing water or place the unit near open water. If used near a water source; be certain there is no 

chance the unit could fall into the water or get splashed and that it is plugged into a dedicated circuit and Ground Fault 

Circuit Interrupter (GFCI) protected outlet. 

•  Install the unit with enough space to access all sides for maintenance and service. The rear panel where the power cord is 

located needs to be removed in order to do repairs. 

• DO NOT use the dehumidifier as a bench or table. 
•   DO NOT place the dehumidifier directly on structural building members without vibration absorbers or unwanted noise may 

result. Place the Santa Fe Impact on supports to raise the base of the unit.

Location Considerations

•  Locate the dehumidifier near a suitable drain (8' drain 

hose included). Allow for proper drainage and routing 

of needed drain pipes. 

•  Locate the dehumidifier in an area where the cord’s 

length (9') easily reaches a 115 VAC electrical outlet 

with a minimum of a 15 Amp circuit capacity.

•  The unit is designed to operate while level. If the unit 

is placed on an unlevel surface, refer to section below 

(Installing Leveling Feet). Failure to level the unit may 

result in leakage or improper drainage.

•  The unit should be suspended with a hang kit from  

the floor joists if there is any possibility of flooding. 

A flooded unit is not covered by warranty. DO NOT 

install the feet if you are using the hang kit. DO NOT 

hang the Santa Fe Impact from its’ cabinet.

•  Allow sufficient clearance to handle the unit’s  

overall dimensions as well as any optional return 

and supply ductwork to the unit. 

•  Allow sufficient clearance for filter removal and to 

prevent airflow obstruction.

•  Electrical service access will require the removal of the rear panel where the power cord is located. Allow sufficient clearance 

around the unit.

Installing Leveling Feet

 

• Lay down a protective pad (pillow, blanket, etc.).
• Carefully turn unit onto side.
• Install leveling feet and adjust to the desired position to ensure unit is level for proper drainage.
• Carefully bring unit to upright position.
•  Wait a minimum of 10 minutes before operating.

Dehumidifier Set Up

MINIMUM

CLEARANCE

FOR FILTER

(EITHER SIDE)

20" 

RETURN AIR

SUPPLY AIR

A

B

TOP VIEW

A

B

MINIMUM CLEARANCE

FOR PROPER AIR FLOW 

OF EXHAUST AIR

12" 

MINIMUM

CLEARANCE

FOR PROPER 

AIR FLOW OF 

INTAKE AIR

12" 

9' POWER CORD

DRAIN

ACCESS

B

 CAUTION!

 

 REMOVE COMPRESSOR SHIPPING TIE FROM THE UNIT. FAILURE TO 

REMOVE SHIPPING TIE WILL CAUSE EXCESS VIBRATION TO BE TRANSMITTED TO THE FRAME.

The Santa Fe Impact uses a compressor to power the refrigeration system. To protect the compressor and 

refrigeration system during shipping a plastic tie wrap secures it to the units frame. Remove the tie wrap 

by cutting the tie wrap and pulling from the unit as shown.  After removing tie wrap, insert plastic plugs 

provided into the holes.

Summary of Contents for 4032230

Page 1: ...ies up to 2 500 square feet and is the ideal unit for meeting aggressive energy use targets The Santa Fe Impact is engineered for extremely quiet operation and is optimized for low heat load P N 40322...

Page 2: ...Precautions 5 Location Considerations 5 Installing Leveling Feet 5 Ducting to Finished Areas Optional 6 Attaching Duct Collars 6 Recommended Installations 7 Drain Installation 8 Operation 9 Humidity C...

Page 3: ...shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or in its air flow The unit is designed to be...

Page 4: ...nts Day 85 Pints Day Efficiency 8 8 Pints kWh 7 8 Pints kWh Energy Factor 4 2 L kWh 3 7 L kWh Air Filter MERV 11 Standard Pleat Size 16 x 20 x 2 Power Cord 9 115 VAC Ground Drain Connection 3 4 Thread...

Page 5: ...a 15 Amp circuit capacity The unit is designed to operate while level If the unit is placed on an unlevel surface refer to section below Installing Leveling Feet Failure to level the unit may result i...

Page 6: ...r duct collar and a front panel are attached to the unit Supply Air Outlet Two 10 diameter duct collars attach to the outlets on each side of the unit CAUTION BOTH EXHAUST OUTLETS MUST BE LEFT OPEN OR...

Page 7: ...m being placed under a negative pressure and also allow the dehumidifier to focus on keeping the unfinished area dry as well The onboard dehumidistat control can be used on the unit for this applicati...

Page 8: ...Optional Drain Port Drain Trap Pretzel Loop Floor Bend PVC Trap PVC materials available from your local hardware store Standard Loop The Santa Fe Impact requires a drain trap Creating a drain trap all...

Page 9: ...he humidity dial clockwise to the recommended NORMAL position and set fan control to FAN AUTO To turn the unit off turn the humidity dial counter clockwise to the OFF position and set fan control to F...

Page 10: ...SE PREMATURE FILTER WEAR OR UNIT DAMAGE MERV 8 Filter Changing the Filter For greatest filtration and efficiency of the Santa Fe Impact it is recommended the air filter be replaced every three to six...

Page 11: ...11 1 800 533 7533 www Santa Fe Products com Santa Fe Impact Installation Operation Instructions MERV Rating Chart Air Filtration http www mechreps com PDF Merv_Rating_Chart pdf...

Page 12: ...Amp circuit capacity If used in an area that may become wet a GFCI protected circuit is recommended The unit should not be used in areas prone to flooding Consult local electrical codes for any furthe...

Page 13: ...TA FE IMPACT WITH ITS HIGH PRESSURE REFRIGERANT SYSTEM AND HIGH VOLTAGE CIRCUITRY PRESENTS A HEALTH HAZARD WHICH COULD RESULT IN DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE ONLY QUALIFIED SERVI...

Page 14: ...s temp Rh you should see some water production out of the hose within 30 minutes or so Note If the room temperature is 55 degrees or below and or in area of low relative humidity the dehumidifier will...

Page 15: ...oes not cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer C...

Page 16: ...www Santa Fe Products com 1 800 533 7533...

Reviews: