Santa Fe 4032230 Installation & Operation Instructions Download Page 4

4

Santa Fe Impact Installation & Operation Instructions

www.Santa-Fe-Products.com | 1-800-533-7533

Specifications

Part Number:

 4032230

Blower:

 

257 CFM @ 0.0" WG

Power:

 

530 watts @ 80°F and 60% RH

Supply Voltage:

 

115 volt – 1phase – 60 Hz

Current Draw:

 

4.9  amps

Operating Temp.:

 

56°F Min., 95°F Max.

Sized For: 

(Refer to website for more sizing considerations)

Crawl Space

  

 

Very Tightly Sealed 

Up to 3,700 Sq. Ft. (18,500 Cu. Ft.) 

Moderately Sealed 

Up to 2,900 Sq. Ft. (14,500 Cu. Ft.) 

Some Leaks & Imperfections 

Up to 2,500 Sq. Ft. (12,500 Cu. Ft.)

Basement

    

Very Tightly Sealed 

Up to 3,000 Sq. Ft. (30,000 Cu. Ft.) 

Moderately Sealed 

Up to 2,700 Sq. Ft. (27,000 Cu. Ft.) 

Some Leaks & Imperfections 

Up to 2,500 Sq. Ft. (25,000 Cu. Ft.)

Minimum Performance at:

  

 

80°F and 60%RH

 

70°F and 60%RH

Water Removal:

  

105 Pints/Day 

85 Pints/Day

Efficiency:

 

8.8 Pints/kWh 

7.8 Pints/kWh 

Energy Factor:

 

4.2 L/kWh 

3.7 L/kWh

Air Filter:

  

MERV-11, Standard Pleat

Size:

 

16" x 20" x 2"

Power Cord:

 

9', 115 VAC, Ground

Drain Connection:

 

3/4" Threaded Female NPT 

Drain Hose:

  

8' Direct Gravity Drain Hose (5/8" ID x 7/8" OD)

Refrigerant Type:

  

 R410A (Refer to manufacturers label for  

more information)

Refrigerant Amount:

  

1 lb., 10 oz.

Dimensions:

 

Unit

 

Shipping

Width: 

20.25" 25"

Height: 

21.75"  

28"

Length: 

38"    

42"

Weight: 

140 lbs  156 lbs

Optional Accessories:

4021475 

MERV-11 Filter (16” x 20” x 2”)

4027420 

MERV-11 Filters 4-Pack 

4027424 

MERV-11 Filters 12-Pack

4028614 

Pump Kit

4028616 

Caster Kit

4036685 

Hang Kit

4028607 

Duct Kit, Supply Only

4028610 

Duct Kit, Return Only

4026969 

10” Flex Duct 25’

4022126 

10” Flex Insulated Duct 25’

4024750 

12” Flex Duct 25’

4028366 

12” Flex Insulated Duct 25’

4020175 

Remote Dehumidistat

21.75"

FRONT

BACK

20.25"

20.25"

38"

21.75"

21.75"

21.75"

FRONT

BACK

20.25"

20.25"

38"

21.75"

21.75"

21.75"

FRONT

BACK

20.25"

20.25"

38"

21.75"

21.75"

Summary of Contents for 4032230

Page 1: ...ies up to 2 500 square feet and is the ideal unit for meeting aggressive energy use targets The Santa Fe Impact is engineered for extremely quiet operation and is optimized for low heat load P N 40322...

Page 2: ...Precautions 5 Location Considerations 5 Installing Leveling Feet 5 Ducting to Finished Areas Optional 6 Attaching Duct Collars 6 Recommended Installations 7 Drain Installation 8 Operation 9 Humidity C...

Page 3: ...shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or in its air flow The unit is designed to be...

Page 4: ...nts Day 85 Pints Day Efficiency 8 8 Pints kWh 7 8 Pints kWh Energy Factor 4 2 L kWh 3 7 L kWh Air Filter MERV 11 Standard Pleat Size 16 x 20 x 2 Power Cord 9 115 VAC Ground Drain Connection 3 4 Thread...

Page 5: ...a 15 Amp circuit capacity The unit is designed to operate while level If the unit is placed on an unlevel surface refer to section below Installing Leveling Feet Failure to level the unit may result i...

Page 6: ...r duct collar and a front panel are attached to the unit Supply Air Outlet Two 10 diameter duct collars attach to the outlets on each side of the unit CAUTION BOTH EXHAUST OUTLETS MUST BE LEFT OPEN OR...

Page 7: ...m being placed under a negative pressure and also allow the dehumidifier to focus on keeping the unfinished area dry as well The onboard dehumidistat control can be used on the unit for this applicati...

Page 8: ...Optional Drain Port Drain Trap Pretzel Loop Floor Bend PVC Trap PVC materials available from your local hardware store Standard Loop The Santa Fe Impact requires a drain trap Creating a drain trap all...

Page 9: ...he humidity dial clockwise to the recommended NORMAL position and set fan control to FAN AUTO To turn the unit off turn the humidity dial counter clockwise to the OFF position and set fan control to F...

Page 10: ...SE PREMATURE FILTER WEAR OR UNIT DAMAGE MERV 8 Filter Changing the Filter For greatest filtration and efficiency of the Santa Fe Impact it is recommended the air filter be replaced every three to six...

Page 11: ...11 1 800 533 7533 www Santa Fe Products com Santa Fe Impact Installation Operation Instructions MERV Rating Chart Air Filtration http www mechreps com PDF Merv_Rating_Chart pdf...

Page 12: ...Amp circuit capacity If used in an area that may become wet a GFCI protected circuit is recommended The unit should not be used in areas prone to flooding Consult local electrical codes for any furthe...

Page 13: ...TA FE IMPACT WITH ITS HIGH PRESSURE REFRIGERANT SYSTEM AND HIGH VOLTAGE CIRCUITRY PRESENTS A HEALTH HAZARD WHICH COULD RESULT IN DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE ONLY QUALIFIED SERVI...

Page 14: ...s temp Rh you should see some water production out of the hose within 30 minutes or so Note If the room temperature is 55 degrees or below and or in area of low relative humidity the dehumidifier will...

Page 15: ...oes not cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer C...

Page 16: ...www Santa Fe Products com 1 800 533 7533...

Reviews: