background image

ENGLISH 

– ENGLISH – ENGLISH – ENGLISH – ENGLISH – ENGLISH – ENGLISH – ENGLISH   

14/

14

 

Technical data 
 

Rated Voltage 

220-230VAC 

Rated frequency 

50HZ 

Total Power(Max) 

2400W 

Power leakage 

<0.25mA 

Insulated resistance 

>50MΩ 

Dielectric strength 

2000V 

Technical description of load configuration 
Load type 

Rated load Voltage  Rated Load 

Frequency 

Rated Load 
Power 

Others 

heater 

230VAC 

50 HZ   

300-400W 

7 sets 

light 

12VDC 

//////// 

1.5W 

1 set 

Ventilator 

12VDC 

//////// 

4W 

1 pc 

Radio,CD,MP3 

12VDC 

//////// 

4W 

 

 
The installment size of control panel 170*140mm Outer size: 170*140mm 

Summary of Contents for D50540

Page 1: ...Deutsch 1 Art Nr D50540 11 2014 ...

Page 2: ...sstoß verlieren wieder zu ersetzen 8 Wenn Sie vor der Benutzung warm oder heiß duschen regen Sie Ihre Schweißdrüsen zusätzlich an Probieren Sie die Infrarotkabine mit und ohne vorherige Dusche aus um festzustellen was Sie bevorzugen Wenn Sie vorher duschen trocknen Sie sich vollständig ab da das Wasser das Holz beschädigen kann 9 Essen Sie mindestens eine Stunde vor der Benutzung nichts Am besten ...

Page 3: ...ikamenten stehen da dies zu einer Bewusstlosigkeit führen kann Transport und Lagerung 1 Setzen Sie die Kabine während des Transports keinem Regen Schnee oder heftigen Kollisionen aus 2 Lagern Sie sie nicht in einer feuchten Umgebung Schimmelbildung ELEKTROINSTALLATION Bauseits Der Elektro Anschluss darf nur von einem behördlich konzessionierten Elektroinstallationsunternehmen durchgeführt werden D...

Page 4: ...rekte und indirekte Haftung auf Personen oder Sachschäden ab Durch indirekte Schäden w z B Folgeschäden durch mangelnden Gebrauch oder allfällige Entfernung haftet der Hersteller nicht Bei Reparaturen nach Ablauf der Garantiezeit werden die ausgetauschten Teile der Arbeitsaufwand und die Fahrtspesen nach den geltenden Sätzen in Rechnung gestellt Die aktuellen Spesensätze können Sie beim Kundendien...

Page 5: ...Deutsch 5 Strahler 230V 50Hz Rücken 3x 400W Boden 1x 300W Front 2x 300W 1 5 Watt 4 2 Watt 4 Watt 2400 Watt Schaltplan ...

Page 6: ...tk 12 6 Schraubenabdeckungen 7 Bodenelement 12 7 Schrauben 4 35 2Stk 8 komplette Rotlichtstrahlerabdeckung 12 8 Gewindebuchsen 10 1 Frontteil 12 9 Innengriff 10 2 Schrauben 4x35 8STk 13 Frontelement inklusive Glastür 10 3 Dreieckige Abdeckung oben unten 14 Rotlichtstrahler 2Stk 9 Schrauben 4x12 8Stk 15 Schrauben 4x35 8Stk 10 Sitzbank 16 Rückenlehne 11 Sitzbankstütze 17 Schrauben 4x35 8Stk 12 Griff...

Page 7: ...ie Stromkabelhalterungen 4 Stk 7 Für die Fußstrahlerverkabelung 10 Stk 8 Für die Fußstrahler Montage 8 Stk 1 2 3 4 5 6 7 8 ST8X45 ST5X60 ST4X35 ST4X12 Φ10 2 Φ8 2 2 pcs 18pcs 18pcs 18pcs 2 pcs 4 pcs 10 pcs 8 pcs 1 Schritt Stellen Sie das Bodenelement auf einen ebenen Untergrund Stellen Sie die Rückwand senkrecht ausgerichtet auf das Bodenelement 2 Schritt Stellen Sie die linke Seitenwand auf das Bo...

Page 8: ... zu montieren 4 Schritt Montieren Sie die Elektronikbox an der Unterseite der Rückwand wie das Bild Dann montieren Sie die Schutzeinrichtung wieder an der Wand 5 Schritt Montieren Sie den Fußstrahler auf die Sitzbankstütze und montieren Sie dann die ganze Sitzbank an der Wand wie auf dem Bild 5 ...

Page 9: ... links und rechts und markieren Sie die Stelle mit einem Stift siehe Bild 7 Nehmen Sie den markierten Punkt als Startpunkt für die Montage der Frontstrahler Befestigen Sie die Strahler in den Ecken und verbinden Sie die Strahler Kabeln mit den Vorverlegten Kabeln montieren Sie danach die Strahler Abdeckungen 8 Schritt Montieren Sie das Dach auf der Kabine Verwenden Sie die Schrauben ST5x60 ...

Page 10: ...Deutsch 10 9 Schritt Öffnen Sie die Glastür und montieren Sie den Griff in den vorgesehenen Löchern ...

Page 11: ...Strahler Gruppe A D FM Radio Indikator Leuchte 07 Strahler Gruppe B E Lautstärke und Zeit 08 Farblicht F Lautstärke Indikator Leuchte 09 Ventilator G Zeit Indikator Leuchte 10 FM Radio H Strahler Gruppe A Indikator Leuchte 11 CD MP3 I Strahler Gruppe B Indikator Leuchte 12 FM Radio Frequenz J Ventilator automatisch Indikator Leuchte 13 FM Radio Frequenz K Power Ein Aus manuel Indikator Leuchte 14 ...

Page 12: ...rleuchte wechselt auf die Farbe Grün der Rotlichtstrahler arbeiten jetzt mit 20 drücken Sie die 2 Tasten mehrmals um die Leistung der Rotlichtstrahler auf 40 80 bzw 100 zu erhöhen wenn Sie die 100 Leistung erreicht haben drücken Sie die 2 Tasten erneut um die Leistung der Rotlichtstrahler wieder auf 80 60 40 bzw auf 20 zu senken 3 Radio Funktion Drücken Sie die Taste um die Radiofunktion zu aktivi...

Page 13: ...ngern System muss aktiv sein Langes Drücken Schnelles Erhöhen Verringern Der Einstellbereich geht von 5 99 Minuten Drücken Sie die Tasten um die Temperatur um jeweils 1 C zu erhöhen bzw zu verringern System muss aktiv sein Langes Drücken Schnelles Erhöhen Verringern Der Einstellbereich geht von 35 60 C Nach dem Einstellen der gewünschten Temperatur wechselt die Anzeige zurück auf die momentane Rau...

Page 14: ... 2600W Leistungsverlust 0 25mA Wiederstand 50MΩ Spannungsfestigkeit 2000V Detaillierte Technische Daten Typen Nennspannung Frequenz Nennleistung Sonstiges Strahler 230VAC 50 HZ 250 300W 7 Stk Licht 12VDC 1 5W 1 Stk Ventilator 12VDC 4W 1 Stk Radio CD MP3 12VDC 4W Bedienelement Außenmaße 170x140mm ...

Page 15: ...H ENGLISH ENGLISH ENGLISH ENGLISH 1 14 Item No D50540 Sanotechnik Handelsgesellschaft m b H Industriestrasse 5 A 2752 Wöllersdorf Tel 0043 2622 421 93 0 Fax 0043 2622 421 93 6 Email office sanotechnik at www sanotechnik com 11 2014 ...

Page 16: ...ower in order to determine what you prefer If you take a shower before please dry off completely because the water can damage the wood 9 Eat at least one hour before using It is best to use with an empty stomach because a full stomach may cause discomfort 10 You can also benefit from the relaxing effect of the infrared cabin by going to bed after use The relaxed state after use will help calm and ...

Page 17: ... collisions 2 Store them in a non humid environment Mold building ELECTRICAL Feeder The electrical connection may be performed by an officially licensed electrical company The installation requirements of local utility companies and the provisions of DIN 57100 and OVE VDE 0100 Part 701 must be strictly complied with The cable sheathed cable H05VV f3G2 5 YMM J 3x2 5 mm up to 3500 watts shall have a...

Page 18: ...to use incorrect installation maintenance by unauthorized personnel due to transport damage such as fuses decorative elements etc Inadequate compliance with the instructions the manufacturer disclaims any direct or indirect liability to persons or property By indirect damage such as damage caused by lack of use or removal of any manufacturer is not liable For repairs after the warranty period the ...

Page 19: ...14 Technical parameter External Dimensions mm Length 1000 Width 1500 Height 1950 Voltage Power of Heater Lampion Ventilation fan Speaker Total Power 230V 50Hz 3 x 400W 2 x 300W 2 x 300W 1 5 Watt 4 2 Watt 4 Watt 2400 Watt Prepare before installation Height Length Width ...

Page 20: ...m board 12 7 mounting screw for inside handle 4 35 2pcs 8 Safety guard for Front Red glass heater 12 8 Insert nuts of Decorative screws 10 1 Safety guard 12 9 Handle inside 10 2 Sunk screws for supporting frame 4 35 8 13 Front panel with glass door 10 3 Triangular supporting frame 4 14 Front Red glass heater 2 9 Round head screws for front Red glass heater 4 12 8pcs 15 Sunk screws for Front Safety...

Page 21: ...ion X16 for the handle installation X2 4 For the wire clip installation X12 For the electricity box installation X4 For the leg heater installation X8 5 For the decoration strip cap X16 6 For the total electric power source wire clip X2 7 For the branch electric power source wire clip X10 8 For the leg heater installation X8 1 2 3 4 5 6 7 8 ST8X45 ST5X60 ST4X35 ST4X12 Φ10 2 Φ8 2 2 pcs 24 pcs 24 pc...

Page 22: ...all and mare sure it is vertically Step 2 Put the left side wall on the left of the bottom board and use the sunk screw 5 60 to install it with the the back wall Attention Please reference the attached pictures to make sure that the mounting will not affect the appearance while mounting Step 3 Use the same mounting processes to install the front wall and the right wall Notice Take care of the glas...

Page 23: ...on the wall Step 5 Install the leg heater on the bench frame in advance Then install the whole bench frame on the wall as the arrowheads of picture Step 6 Please refer the Wire sketch and connect all the wires as the label of the connector Sort out and fix well all the wires Then place the bench board on the frame after double check and make sure all the wires are connected correctly ...

Page 24: ...all the wires of the cabin and fixed them on the side walls Please make sure the outer hull of the heater not connect with the wires 2 Please install the outer hull of the heater on the wall with the silicon cushion and fasten it with screws 3 Please the heater is level the 90deg corner or else it can not install the safety guard well Step 8 Install the Roof on the cabin with the sunk screw 5 60 a...

Page 25: ...05 MP3 USB input C FM tune indicator light 06 Infrared sauna group A D Volume time 07 Infrared sauna groub B E Volume adjust indicator light 08 Colour light F Time setting indicator light 09 Fan G Infrared sauna group A light 10 FM H Infrared sauna group B light 11 CD MP3 I Automatic fan indicator light 12 FM frequency J Fan by hand indicator light 13 FM frequency K Power on off indicator light 14...

Page 26: ...e red glass heather now works 30 press the two key several times to increase the power of the red light emitter by 10 maximum 100 or if you have the 100 achieved power press the 2 key again in order to reduce the power of the red light emitters by 10 minimum 30 3 Radio function Press the Radio button to switch on the Radio when the system is booting The Radio light turns green The dynamic screen s...

Page 27: ... 9 Time Temperature setting Press the button to raise the temperature for always 1 minute or to reduce The system has to be on working status keep on long press the button more than one second can adjust the item quickly The adjustment range is 5 99 minutes Adjust the temperature up and down at 1 minute by press button when the system is on working status Keep on long press the button more than on...

Page 28: ... leakage 0 25mA Insulated resistance 50MΩ Dielectric strength 2000V Technical description of load configuration Load type Rated load Voltage Rated Load Frequency Rated Load Power Others heater 230VAC 50 HZ 300 400W 7 sets light 12VDC 1 5W 1 set Ventilator 12VDC 4W 1 pc Radio CD MP3 12VDC 4W The installment size of control panel 170 140mm Outer size 170 140mm ...