background image

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

SANKI COMPANY LIMITED. 

Sendai Office   Tel: +81-22-263-8345  Fax: +81-22-263-8354 

Tokyo Office    Tel: +81-3-3493-6187  Fax: +81-3-3493-6195 

Nagoya Office   Tel: +81-52-691-1147  Fax: +81-52-692-1915 

Osaka Office     Tel: +81-6-6746-8222  Fax: +81-6-6746-8224 

 

 

 

 

 

 

 

 

 

http://www.sanki-web.co.jp 

 

 

Summary of Contents for P212

Page 1: ...ntroller version 2 and later Confirm the version information displayed upon powering ON Ver 2 Read the Manual carefully beforehand to ensure the safe use of the Controller After reading store the Manu...

Page 2: ......

Page 3: ...n of Operation Panel 7 2 Displayed Mode 7 3 Setting the Frequency Lock 7 4 Preparation for Operation Operation and Amplitude Adjustment Method Added Function 10 Initialization of the Set Data 11 Remot...

Page 4: ...the packing Unpack and check the following 1 Isn t there any damage caused during transport 2 Are the rating capacity and model on the nameplate exactly what you have ordered If there is any problem...

Page 5: ...e or the output cable or an electric shock or a fire could be caused Ground the earth terminal and the ground prescribed portions without fail or an electric shock could be caused When working on grou...

Page 6: ...cable 1m Operation panel Rubber bush Relay connector Operation panel fixing screw 2 locations Earth Operation panel connecting wire Operation panel When attaching detaching the operation panel carefu...

Page 7: ...flat blade screwdriver or similar insert the wire into the wire insertion hole Then detach the flat blade screwdriver to release the button and the wire will be fixed Applicable wire size Stranded wir...

Page 8: ...es Connect the external I O signals Amplitude adjustment Adjust the amplitude to optimize the work transfer speed Outputs the setting output voltage frequency for a certain length of time Set the outp...

Page 9: ...nnect any feeder other than the piezo feeder made by Sanki 2 Do not operate with no load 3 Be sure to ground the feeder 2 Power source connection Connect the power cable to the single phase power sour...

Page 10: ...f the controller according to external control signal either method of non voltage contact signal or voltage signal 24VDC can be used Make connection to the external control terminal block by using th...

Page 11: ...sed briefly when the voltage is being displayed the voltage display switches to the frequency display Frequency lock setting display Changes the frequency lock setting Parameter mode Changes the param...

Page 12: ...ays the current setting When the Func key is pressed again the voltage is displayed Voltage Frequency F LOCK Voltage To select the setting press the Freq key or Freq key To execute the setting change...

Page 13: ...control is OFF Quick blinking In forced operation Slow blinking Forced operation at a stop Forced operation means Forcedly starting stopping the operation by pressing the ON OFF button whether the op...

Page 14: ...screen to the frequency setting screen Switches the frequency setting screen to the output setting screen Vol keys Lowers the output until the speed is lowered to the speed at which the parts moves s...

Page 15: ...ialization of the Set Data Returning to the factory setting 1 When the Controller is in the Power OFF status power ON the Controller by pressing the Vol key and the Freq key together The Controller st...

Page 16: ...iable voltage input 3 contacts No voltage contact input 2 Connection Connect the remote unit to the terminal block of the main unit of the Controller Px12 3 Usage 1 Set the remote unit to valid Parame...

Page 17: ...hout pressing the Set key in the change process the changes will not be saved but cancelled If there is no key operation for over 5 min the normal mode screen voltage display will be forced to reappea...

Page 18: ...y Reset the error by either of the following methods 1 and 2 When resetting the error eliminate the abnormality beforehand If the external signal is an operation condition be careful that the Controll...

Page 19: ...lock The overcurrent error E 01 is displayed The feeder is probably abnormal Contact the dealer Ground fault was caused due to damage to the controller output cable cover or the feeder wire cover Repl...

Page 20: ...or 24VDC Others Soft start soft stop short circuit protection etc Power outlet 24VDC 160mA Operating temperature range 0 40 Operating humidity range 30 90 no condensation Place of use Indoor no corro...

Page 21: ...19 20 17 Outside Dimensional Drawing The input and output cables are omitted...

Page 22: ...y a fire an earthquake a flood or the like or unspecified power source voltage frequency Failure caused by improper handling or operation Failure caused by handling against the usage specifications or...

Page 23: ......

Page 24: ...ai Office Tel 81 22 263 8345 Fax 81 22 263 8354 Tokyo Office Tel 81 3 3493 6187 Fax 81 3 3493 6195 Nagoya Office Tel 81 52 691 1147 Fax 81 52 692 1915 Osaka Office Tel 81 6 6746 8222 Fax 81 6 6746 822...

Reviews: