8-2 Conflict & Interference Error
8-2
Conflict & interference error
During function code entering, a conflict & interference error will be displayed when the entered data
conflicts with the settings of other function codes. The displayed 4-digit number is the number of conflict &
interference function code.
The entered data is invalid when a conflict & interference error is displayed. Please correct it to a value
without a conflict, or change the values of the conflict & interference function code.
For function code and error display related to conflict and interference, please refer to Table 8.2.
8-2-1
List of conflict & interference error
Table 8.2 List of conflict & interference error
Setting function code
Error code
Description
No.
Name
Setting
1001
Motor control mode
selection
All
(exclude 1
and 40)
E5001
The setting motor cannot be used in vector
control
E1007/E1316/E1317
Exceed the upper frequency limit
2
E1901
Simple energy-saving function (only in V/f
mode) cannot be used in vector control mode
3
E1002
Cannot set PG input repeatedly
E1901
Simple energy-saving (only in V/f mode), cannot
be used in vector control mode
4
E1901
Energy-saving mode cannot be used in torque
control
E2201
Pattern, disturbed operation cannot be used in
torque control
E3201
PID control action cannot be used in torque
control
5
E1002
Cannot set PG input repeatedly
E1901
Energy-saving mode cannot be used in torque
control
E2201
Pattern, disturbed operation cannot be used in
torque control
E3201
PID control action cannot be used in position
control
6
E1002
Cannot set PG input repeatedly
E1101
Position control mode is only effective when
operation command is external terminal
E1901
Energy-saving mode cannot be used in position
control
E2201
Pattern, disturbed operation cannot be used in
position control
E3201
PID control action cannot be used in torque
control
10,11
E1901
Energy-saving mode cannot be set when motor
parameter are measured automatically
E2201
Pattern, disturbed operation cannot be set during
automatic measurement
E3201
PID control action cannot be set during automatic
measurement
40
E1901
Energy-saving mode cannot be set during V•f
separation control
E2201
Pattern, disturbed operation cannot be set in V•f
separation mode
E3201
PID control action cannot be set in V•f separation
mode
All
Exxxx
Cannot set analog input repeatedly