Troubleshooting
Problem
Cause
Solution
No water outlet
Stop valves are closed
Open the stop valves
Filters are clogged
Clean or replace
Hoses are twisted or bent
Connect correctly the hoses
Mixer blocked in anti-scald security
–
cold water
failure
Check pressure presence
Reduced flow rate
Wrong supply of mixed
water
Filters are clogged
Clean or replace
Stop valves are not opened enough
Open the stop valves
Hoses are twisted or bent
Connect correctly the hoses
Pressure is too low
Check the pipelines
Cartridge has been improperly configured
Adjust the
cartridge (see page ……)
Cartouche is obstructed or dirty
Clean or replace
Flow aerator obstructed
Clean or replace
The pressions of hot and cold water are unbalanced
Find the good pressure balance;
Δ
P < 1bar
The temperature difference between cold and hot
water is too low
Check the water inlets
Hoses are twisted or bent
Connect correctly the hoses
Stop valves are not opened enough
Open the stop valves
Connection warm and cold water inverted
Check the connections
Water flows constantly
Cartridge is obstructed or dirty
Clean or replace
Cartridge out of order
Replace
Wrong time flow rate (too
short or too long)
Wrong position of the limiter
Adjust the flow time limiter (see
page……)
Reduced flow rate
See « Reduced flow rate »
Important informations
Obtain the correct inlet pressures and adjust them to 3 bar.
Don’t squeeze or bend the hoses
.
The taps must be installed by qualified technician.
Mandatory installation of the filter seals
–
the installation of stop valves makes the access to
maintenance easier.