15. TECHNICAL FEATURES 

 

SANICA FIJI HERMETIC COMBI TECHNICAL FEATURES

 

CONVENTIONAL COMBI MODELS 

  

FIJI 24  FIJI 28 

Heating Circuit Heat Power Max 

kW 

24 

27,5 

Heating Circuit Heat Load Max 

kW 

25,9 

29,5 

Heating Circuit Heat Power Min 

kW 

9,3 

11,1 

Heating Circuit Max Pressure 

bar 

Minimum Water Pressure 

bar 

0,5 

0,5 

Expansion Tank Capacity 

Litre 

Expansion Tank Pre-Pressure 

bar 

Min. Usage Water Flow 

I/dk 

Max Use Water Flow 

(ΔT = 30 ° C)

 

I/dk 

11 

13 

Minimum Working Pressure 

bar 

0,3 

0,3 

Burner Pressure at Max Heat Load 

mbar 

11 

11 

Burner Pressure at Min Heat Load 

mbar 

1,7 

1,7 

Max Chimney Length 

Gas type 

  

G20 

G20 

Heating Circuit Setting temperature 

°C

 

30-80  30-80 

Domestic Water Circuit Setting temp. 

°C

 

35-60  35-60 

Natural gas supply pressure 

mbar 

20 

20 

Supply voltage 

230 

230 

Frequency 

Hz 

50 

50 

Electric charge 

140 

140 

Height 

mm 

717 

717 

Width 

mm 

400 

400 

Depth 

mm 

330 

330 

Net weight 

kg 

28 

33 

Electrical protection class 

  

IP X4D  IP X4D 

 

Figure 14 

Summary of Contents for FIJI

Page 1: ...1 FIJI 24 28 KW HERMETIC CONVENTIONAL BOILER INSTALLATION AND USER MANUAL ...

Page 2: ...NG THE BOILER 4 5 DAILY USAGE OF THE BOILER 5 6 FILLING BOILER WITH WATER 6 8 BOILER MAINTENANCE 7 9 INSTALLATION INSTRUCTIONS 8 10 BOILER DIMENSIONS 9 11 FLUE CONNECTION 9 12 ELECTRICAL CONNECTION 12 13 CIRCUIT SCHEME AND ROOM THERMOSTAT 12 14 MALFUNCTION CODES 13 15 TECHNICAL FEATURES 14 ...

Page 3: ... is not connected with any device other than the special chimney used for connecting more than one device and that the chimney head is not blocked c It should be ensured that the boiler will be used with a suitable gas d It should be ensured that the connected piping and pipes are cleaned before installation Otherwise malfunctions caused by dirt and particles in the installation are out of the sco...

Page 4: ...and lightning g Malfunctions caused by low or high voltage or not grounding h Malfunctions arising from not having the described periodic maintenance works deliv ered by our authorized services on time I Malfunctions caused by other accessories and products used with the device j Damages caused by frost k Falsification of the registration label and warranty certificate l Malfunctions caused by ope...

Page 5: ...ection is not active a When the device is used in summer mode and domestic water circuit there is mark on the screen For domestic water adjustment adjust the button in the direction of the thickness of the lines and adjust the desired temperature by looking on the screen Pump blockage protection and frost protection are active in the summer position b When the device is switched to winter mode the...

Page 6: ...3 located at the bottom of the device While the device is cold the water level should be filled in a range of 1 1 5 bars on the manometer located on the front of the device Figure 2 When the water pressure of the device drops to a critical level the device automatically stops WARNING In order to fill the device with water it must be switched to heating winter mode When the device is in domestic wa...

Page 7: ... be observed When the water in the device falls below 5 degrees it is activated and heats up to 30 degrees 8 BOILER MAINTENANCE In order to use your device smoothly and efficiently for a long time have it annually examined by the authorized service at the beginning of the season Never clean the outer surface of your device with detergent or chemicals Check your installment before connecting the de...

Page 8: ...eave a gap of 50 cm from the top 15 cm from the sides and 40 cm from the bottom where the boiler will be mounted For water connections a filter and a ball valve must be installed at the inlets of the combi Figure 5 The mains inlet should not be over the 8 bar pressure limit In cases with higher network pressure a pressure reducer must be installed The suitability of the gas installation and the de...

Page 9: ...complied with Chimney connection cannot be applied to the following places a In the stairwells of the buildings b Building corridors c To the wells D On the chimney wall e To the balconies f elevator shafts The following points should be taken into consideration in the flue connection a In cases where the chimney is removed from the roof care should be taken to keep the chimney inlet 1 5 m from th...

Page 10: ...e insulated with fire resistant material f The maximum chimney length of the device is 3 m Maximum chimney length is short ened by 1 m for each 90 elbow and 0 5 m for each 45 pole g In vertical chimney applications roof tightness must be fully ensured Possible malfunc tions that may occur in the device in cases where the sealing is not ensured are excluded from the scope of warranty Şekil 7 Şekil ...

Page 11: ...t of the package should be used for horizontal and vertical extension flue connections PRODUCT CHIMNEY SIZE m WASHER mm FIJI 24 KW 3 Ø45 2 Ø43 1 Ø41 FIJI 28 KW 3 Ø48 2 Ø46 1 Ø44 2 m Figure 9 Şekil 10 Lmax Lmax L L L L Lmax 4m Lmax 4m L L 2m L L 3m ...

Page 12: ...ction shown in Figure 12 is removed on the card and the room thermostat connection cables are installed instead Simple type and digital type room thermostats can be connected with this connection Please contact the authorized service for room thermostat connections that operate all functions of the device including domestic water Figure 12 Please contact the authorized service for room thermostat ...

Page 13: ...he nearest authorized service MALFUNCTION CODE WARNING LED TO DO NO FLAME WARNING E01 RED TURN THE DEVİCE OFF ON SAFETY THERMOSTAT WARNING E02 RED TURN THE DEVİCE OFF ON AIR PRESSURE SWITCH WARNING E03 RED TURN THE DEVİCE OFF ON LOW WATER PRESSURE WARNING E04 RED CHECK WATER PRESSURE DOMESTIC WATER SENSOR WARNING E06 YELLOW TURN THE DEVİCE OFF ON HEATING WATER SENSOR WARNING E07 YELLOW TURN THE DE...

Page 14: ...bar 1 1 Min Usage Water Flow I dk 3 3 Max Use Water Flow ΔT 30 C I dk 11 13 Minimum Working Pressure bar 0 3 0 3 Burner Pressure at Max Heat Load mbar 11 11 Burner Pressure at Min Heat Load mbar 1 7 1 7 Max Chimney Length m 3 3 Gas type G20 G20 Heating Circuit Setting temperature C 30 80 30 80 Domestic Water Circuit Setting temp C 35 60 35 60 Natural gas supply pressure mbar 20 20 Supply voltage V...

Page 15: ...This document is for informational purposes only SANICA reserves the right to make changes in its products user and assembly manuals for development improvement purposes without prior notice ...

Reviews: