background image

 Powersaver Boost

 (PSB)

 Installation Instructions

WARNING - ISOLATE THE MAINS 

BEFORE INSTALLATION & SERVICING

THIS INSTALLATION SHOULD BE 

CARRIED OUT BY A SUITABLY QUALIFIED 

PERSON, IN ACCORDANCE WITH THE 

CURRENT EDITION OF THE IEE WIRING 

REGULATIONS.
WARNING: All Powersaver products must 

be earthed, using the earth terminals at 

the rear of the switch. 
The following cabling is recommended:

L & N In   - 1.5mm² - 4.0mm² fixed

L & N Out - 1.5mm² - 2.5mm² flexible 
For retro fit applications, only in 

conjunction with 143609 surface box:

L & N Out - 1.5mm² - 2.5mm² fixed or 

flexible.
Provision must be made in the fixed 

wiring for a means of disconnection from 

the supply having a contact separation 

of at least 3mm on all poles. This can be 

provided by the consumer unit.

The Powersaver product range are 

independently mounted time switches, 

of electronic construction, which can be 

surface or flush mounted. For flush fitting 

a metal box of at least 32mm internal 

depth should be fitted with the earth 

terminal at the bottom.

For surface mounting use a patress box 

with a minimum internal depth of 32mm.
Do not remove the Powersaver from its 

packaging until the patress/wall box is 

fitted and cleared of dust & debris. The 

Powersaver range is suitable for use in a 

normal pollution situation.
The cable clamp at the rear of the unit is 

for outgoing cables to the appliance only.

CONNECTION WARNING:

 Isolate mains 

before installing. Supply terminals are 

for fixed wiring only. Load terminals are 

for fixed or flexible wiring. Remove 8mm 

of insulation from each wire & twist any 

multiple connection together.
All earth conductors must be sleeved 

Fit & forget...

Powersaver Select 

(PSS)

(green/yellow) and connected to earth 

terminals provided on rear of switch. Fit 

the Powersaver to the patress box using 

screws provided.
When cutting the aperture for the output 

flexible cord ensure no sharp edges 

remain.

PLEASE NOTE:

 This product is not 

suitable for mounting on unearthed metal 

or metallic surfaces.

Flush 

Mounting

Surface

Mounting

L

N Out

N

L Out

EARTH

LIVE

NEUTRAL

LOAD

MAINS IN

 Wiring Diagram

 Installation Diagrams

 Programming

POWERSAVER BOOST (PSB)

The Powersaver Boost offers 3 options for 

the on period duration using the BOOST 

button.
Press once = ½ hour

Press twice = 1 hour

Press three times = 2 hour

Press four times = Cancel function
While the Boost is active the indicator 

light will change to show the maximum 

remaining time; e.g. 2 Hours selected

POWERSAVER SELECT (PSS)
The Powersaver Select offers a maximum 

of 3 on & 3 off operations to be set each 

day according to the programming cycle 

selected below.
• 

 1 = 24 hour cycle (default) - All days 

are programmed the same.

• 

2 = 5/2 day cycle - Mon-Fri are 

programmed the same, Sat-Sun have 

separate programs.

• 

3 = 7 day cycle - Each day is 

independently programmable.

Program Setting Mode

Reset/Initial

Program Cycle 

(Reset/Initial only)

Set Month

Set Time

Set Year

Set Date

7 Day

5/2 Day

24 Hour

Normal Display 

(outwith program)

Normal Display 

(during program)

Boost Mode

Holiday Mode

Keypad Locked

This programming cycle selection is only 

offered as part of the initial product set up 

or if a Product Reset has been carried out. 

Under normal conditions the programming 

cycle selection display is not shown.
Programming Cycle Program Methods:

1. 

Press SET to exit initial reset display 

if shown.

2.  Press SET to scroll through & review 

settings in sequence.

3.  Press - & + to adjust these settings.

4. 

7 day cycle ONLY - Press BOOST to 

copy programs into the next day.

5. 

7 day cycle ONLY - Press OFF/ON to 

skip to a day

6.  If a button is not pressed within 30 

seconds, the unit will revert back to 

the normal running state.

Typical Displays:
Cycle/Date/Time Setting Mode

Reviews: