CHOICE PR2

2 Channel Programmer

Installation Instructions

Technical Data

Power Supply:    

230V AC, 50Hz

Operating Temperature:   0°C to 35°C

Total Switch Rating:  

230V AC, 6(2)A

Contact Type:    

1B , Micro-Disconnection (Voltage Free)

Battery Type:  

 

Lithium Cell CR2032

Enclosure Protection:  

IP30

Plastics:  

 

Thermoplastic, flame retardant

Insulation Class:   

Double

Wiring:    

 

For fixed wiring only

Backplate:  

 

Industry standard

Dimensions:  

 

140mm x 87mm x 37mm

Clock:    

 

12 hour am/pm, 1 minute resolution

BST/GMT time change:   Automatic

Clock Accuracy:    

+/- 1 sec/day

Program Cycle:    

24hr, 5/2day or 7day selectable.

Program On/offs per day:  2on/off, 3on/off selectable

Program Resolution:  

10mins

Program Selection:  

Auto, On all day, On constant, Off

Program Override:  

+1,2 or 3Hr, Advance

Heating System:   

Pumped, Gravity selectable

Complies with : EN60730-1, EN60730-2.7, EMC Directive 2004/108/EC,

LVD Directive 2006/95/EC

Fit & forget...

Pre-Installation Set Up

Before installing, set the bank of 

4 DIP Switches on the back to 

configure the unit according to the 

chart below:

DIP Switches 

Shown in Factory Default 

Positions.  (black  =  raised  actuator  of 

switch)

PUMPED allows independent control of CH 

and HW.

GRAVITY  does  not  allow  CH  without  HW 

but can provide HW without CH.

24 Hr Runs same programme every day.

5/2 Day  Allows  different  on/off  times  at 

weekend.

7 Day Allows  different  on/off  times  every 

day.

Installation Safety Notes

This  unit  must  be  installed  by 

a  suitably  qualified  person  in 

accordance  with  the  latest  IEE 

Wiring Regulations.

Isolate mains supply before 

commencing  installation.  Please 

read  all  installation  instructions 

before proceeding.

Ensure  that  the  fixed  wiring 

connections to the mains supply 

is  via  a  fuse  rated  at  not  more 

than 6 amps and a class ‘A’ switch 

having a contact separation of 

a  minimum  of  3mm  in  all  poles. 

The recommended cable sizes are 

1.0mm

2

 or 1.5mm

2

Fitting Back Plate – 

Direct Wall Mounting

1. 

Position the wall-plate 

(terminals  along  top  edge) 

with 60mm (min) clearance to 

its right, 25mm (min) above, 

90mm  (min)  below.  Ensure 

that the supporting surface 

will fully cover the back of the 

programmer.

2.  The  ideal  location  would  be 

1.4M  above  floor  level,  easily 

accessible,  reasonably  lit  and 

free  from  condensation  or 

temperature extremes.

3. 

Offer the back plate to the 

wall in the position where the 

programmer is to be mounted 

remembering that the back 

plate fits to the left hand side 

of  the  programmer.  Mark  the 

fixing  positions  through  the 

slots in the backplate, drill and 

plug wall, then secure back 

plate in position using screws.

4. 

All necessary electrical 

connections  should  now  be 

made.  Ensure  that  the  wiring 

to the wall-plate terminals 

leads  directly  away  from  the 

terminals  and  is  completely 

enclosed  within  the  wall-plate 

Fitting Back Plate – 

Wiring Box Mounting

1.  Fix  the  wall-plate  to  a  flush 

mounting  single  conduit  box 

type UA1 (BS4662) using 

M3.5 x 14 screws. Take care to 

ensure the opening is adequate 

and will allow mounting of the 

unit  onto  the  base  plate.  The 

use of glue, mastic, or other 

sealants MUST NOT be used to 

secure the unit to the wall.

2. 

All necessary electrical 

connections  should  now  be 

made.  Ensure  that  the  wiring 

to the wall-plate terminals 

leads  directly  away  from  the 

terminals  and  is  completely 

enclosed  within  the  wall-plate 

aperture.  Wire  ends  must  be 

stripped  and  screwed  to  the 

terminals so that minimal bare 

wire is showing.

aperture.  Wire  ends  must  be 

stripped  and  screwed  to  the 

terminals so that minimal bare 

wire is showing.

If  the  unit  is  fitted  to  a  metal 

surface, 

IT IS ESSENTIAL 

that 

the metal be earthed.

DO NOT 

use a surface mounting 

box.

No  earth  connection  is  required 

as the product is double insulated 

but ensure continuity of earth 

throughout the system.

New Installations

Example circuit diagrams for typical 

installations  are  shown  below. 

These diagrams are schematic and 

should be used as a guide only.

Please ensure that all installations 

comply with the current IEE 

regulations.

For reasons of space and clarity not 

every  system  has  been  included 

and  the  diagrams  have  been 

simplified, for instance some Earth 

connections have been omitted.

Other control components shown 

in  the  diagrams  i.e.  Valves, 