pITX-iMX8M – User Guide Rev. 1.4
www.kontron.com
// 22
4.2.
Environmental Conditions
Table 5: Environmental Conditions
Storage
Temperature
IEC 60068-2-1 60068-2-2
-40°C to +85°C
Operating
Temperature
IEC 60068-2-1 60068-2-2
-40°C to +85°C for Industrial variants (44011-xxxx-13-x)
0°C to +60°C for Commercial variants (44011-xxxx-15-x)
Note: The pITX-IMX8M requires a cooling solution for proper operation. Kontron offers
passive and active cooling solutions for operation temperature up to 60°C ambient.
Please contact Kontron for customer specific cooling solutions.
Humidity
IEC 60068-2-78
50% to 95% Relative Humidity at 25°C to 30°C, non- condensing
RoHS
RoHS II compliant
REACH Compliance
Regulation (EC) No 1907/2006
EMC and EMI
EN55032 [Must compliance with no deviation allowed] Class B radiated and conducted
EN 61000-6-3:2007 [Must compliance with no deviation allowed]
(EMC) Generic emission standard Part 6-4: Emission standard for commercial
environments
IEC 61000 PT4-2, (EN 61000-4-2) Electrostatic discharge immunity ESD
IEC 61000 PT4-3, (EN 61000-4-3 and ENV 50204) Radiated
Field
IEC 61000 PT4-4, (EN 61000-4-4) Electrical fast transient/burst (EFT) BURST
IEC 61000 PT4-5, (EN 61000-4-5) Surge immunity test
IEC 61000 PT4-6, (EN 61000-4-6) Immunity to conducted disturbances
IEC 61000 PT4-8, (EN 61000-4-8) Immunity to magnetic fields (LOW)
IEC 61000 PT4-11, (EN 61000-4-11) Testing and measuring techniques-voltage dips, short
interruption, and voltage variations immunity tests
Safety
EN 62368-1
Safety for information technology equipment including electrical business equipment
Altitude
2000 m max
Shock
IEC 60068-2-27
Operation, half-sine wave, Acceleration: 2 g, Pulse duration: 11 ms
Number of shocks: 18 shocks (3 shocks for each face)
Vibration
IEC 60068-2-64
Operation, sinusoidal, 10 to 300 Hz, 2g Acceleration, 1 oct/min, 20 cycles per axis, 3
directions.
Reliability
including MTBF
5 years x 365 days x 24 hours
The MTBF value according to Telcordia standard
Power Supply Specifications
Voltage Ripple
Voltage Ripple maximum 100 mV peak to peak 0-20 MHz
Rise Time
2 ms to 20 ms rise time from input voltage <10% to nominal VCC
If any of the supply voltages drops below the allowed operating level longer than the
specified hold-up time, all the supply voltages should be shut down and left OFF for a time
long enough to allow the internal board voltages to discharge sufficiently.
If the OFF time is not observed, parts of the board or attached peripherals may work
incorrectly or even suffer a reduction of MTBF.
The minimum OFF time depends on the implemented PSU model and other electrical factors
and needs to be measured individually for each case.
Summary of Contents for Kontron pITX-iMX8M
Page 1: ...USER GUIDE pITX iMX8M User Guide Rev 1 4 Doc ID 1064 7940...
Page 2: ...pITX iMX8M User Guide Rev 1 4 This page has been intentionally left blank...
Page 23: ...pITX iMX8M User Guide Rev 1 4 www kontron com 23 4 3 Block Diagram Figure 3 Block Diagram...
Page 24: ...pITX iMX8M User Guide Rev 1 4 www kontron com 24...