Connect the other ends of the DC power wires to the connections of the DC main power supply. Pay attention to
the polarity of the connections.
5.
Switch on the disconnecting device (circuit breaker) in order to apply voltage to the terminals of the power wires.
9.2.
Power OFF/ON Procedure
As the KBox C-103-CFL is equipped with an internal hold-up buffer, it can’t be powered off/on immediately.
The buffer time depends on the power consumption and load on the KBox C-103-CFL processor and peripherals.
Therefore the following procedure must be observed.
1.
Close your applications and perform an orderly shutdown (graceful shutdown).
2.
Remove power from the system.
3.
Wait until the green power LED (Figure 15, pos. 2) stops blinking.
4.
Reapply power.
Refer also to the subsection 4.5.7 “POWER Button and PWR LED”.
Do not disconnect the power from your system while it is powered up!
Performing a forced shutdown can lead to loss of data or other undesirable effects!
9.3.
Operating System and Hardware Component Drivers
Your system can be supplied optionally with a pre-installed operating system.
If you have ordered your KBox C-103-CFL with a pre-installed operating system, all drivers are installed in accordance
with the system configuration ordered (optional hardware components). Your system is fully operational when you
power it on for the first time.
If you have ordered The KBox C-103-CFL without a pre-installed operating system, you will need to install the
operating system and the appropriate drivers for the system configuration you have ordered (optional hardware
components) yourself.
You can download the relevant drivers for the installed hardware from our web site at
www.kontron.com by selecting the product.
Pay attention to the manufacturer specifications of the operating system and the integrated