background image

 

USER GUIDE

 

 
 

 

www.kontron.com 

 

// 1 

 

 

COMe-bV26  

Rev. 1.0, User Guide  

Doc. ID: 1068 6561 

 

Summary of Contents for kontron COMe-bV26

Page 1: ...USER GUIDE www kontron com 1 COMe bV26 Rev 1 0 User Guide Doc ID 1068 6561...

Page 2: ...COMe bV26 Rev 1 0 User Guide www kontron com 2 This page has been intentionally left blank...

Page 3: ...uitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions which ma...

Page 4: ...r products and applications you should provide adequate design and operating safeguards You are solely responsible for compliance with all legal regulatory safety and security related requirements con...

Page 5: ...pport Find Kontron contacts by visiting https www kontron com en support Customer Service As a trusted technology innovator and global solutions provider Kontron extends its embedded market strengths...

Page 6: ...ribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitive...

Page 7: ...ral grounding point shall remain connected The earth ground cable shall be the last cable to be disconnected or the first cable to be connected when performing installation or removal procedures on th...

Page 8: ...oduct then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Quality and Environmental M...

Page 9: ...ules 0 C to 60 C 17 2 1 2 Extended Temperature Grade Modules E1 25 C to 75 C 17 2 2 Accessories 17 2 3 Functional Specification 19 2 3 1 Block Diagram 19 2 3 2 Accelerated Processing Unit APU 19 2 3 3...

Page 10: ...ash Chip 40 3 9 TPM 2 0 40 3 10 UART 41 3 11 Watchdog Timer WTD Dual Stage 41 3 11 1 Watchdog Timer Signal 42 4 System Resources 43 4 1 I2C Bus 43 4 2 System Management SM Bus 43 5 COMe Interface Conn...

Page 11: ...able 13 Country Compliance 34 Table 14 MTBF 35 Table 15 Supported Power States Function 38 Table 16 SPI Boot Pin Configuration 40 Table 17 Supported SPI Boot Flash Types 40 Table 18 Dual Staged Watchd...

Page 12: ...Figure 8 Module and Carrier Height 37 Figure 9 Cooling Concept Dimensions 37 Figure 10 COM bV26 Bottom Side 44 Figure 11 Setup menu Selection Bar 64 Figure 12 Main Setup Menu 65 Figure 13 Advanced Se...

Page 13: ...g Unit GPU and Fusion Controller Hub FCH on a single chip known as Accelerated Processing Unit APU Key features are AMD embedded V 2000 series high performance ZEN2 processor Basic form factor COM Exp...

Page 14: ...larification COM Express defines a Computer On Module COM with all the components necessary for a bootable host computer packaged as a super component The product name for Kontron COM Express Computer...

Page 15: ...VI 3x 3x SPI 1x 1x LPC 1x 1x used for external LPC on carrier board External SMB 1x 1x External I2C 1x 1x SDIO shared with GPIO 1x option GPIO or SDIO 8x 8x GPIO UART 2 wire COM 2x 2x FAN PWM out 1x 1...

Page 16: ...Express carrier board can work with several successive generations of COM Express modules A COM Express carrier board design has many advantages of a customized computer board design and additionally...

Page 17: ...n Module with AMD V2516 6x2 1GHz 2x DDR4 non ECC ECC SO DIMM 2 1 2 Extended Temperature Grade Modules E1 25 C to 75 C Extended Temperature Grade Modules E1 25 C to 75 C are available as a standard pro...

Page 18: ...BV26 DDR4 3200 SODIMM 16GB_BV26 DDR4 3200 16 GByte no ECC 97020 3232 BV26 DDR4 3200 SODIMM 32GB_BV26 DDR4 3200 32 GByte no ECC 97030 0432 BV26 DDR4 3200 SODIMM 4GB ECC_BV26 DDR4 3200 4 GByte with ECC...

Page 19: ...ector Option Standard component Embedded Controller HWM GFX FAN1 VCC 5VSB VBAT HWM Power sequencing Watchdog I2C GPIO Buffer I2C EEPROM UART COM Express connector CD Pin out Type 6 VCC DP SPD eDP2 LVD...

Page 20: ...ry Controller Dual Channel Dual Channel Dual Channel Dual Channel ECC memory Support Yes Yes Yes Yes GPU Band AMD Radeon Graphics AMD Radeon Graphics AMD Radeon Graphics AMD Radeon Graphics GPU Max 16...

Page 21: ...memory modules for prototype system s in order to prove the stability of the system and as a reference For volume production if required test and qualify other types of RAM In order to qualify RAM it...

Page 22: ...using a PCIe switch connected to one of the processor s PCIe lanes The following table lists the supported standard PCI Express Gen 3 lane configurations COMe Connector GPP Lane Supported Lane Config...

Page 23: ...SB hub and or a maximum of up to eight USB 2 0 ports where four ports are dedicated USB 2 0 ports The following table lists the supported USB features USB ports 4x USB 3 1 Gen 2 10 Gb s USB 2 0 backwa...

Page 24: ...Ethernet LAN The COMe bV26 supports one 10 100 1000Base T or 2 5 GbE Ethernet controller port The following table lists the Ethernet port connections COMe Connector PCIe Switch Lane Description GBE0 1...

Page 25: ...ux Yocto based Custom BIOS Settings Flash Backup Supported 2 3 14 Additional Features The following table lists General Special and Optional COMe bV26 features General Features Fast I2C Connected to m...

Page 26: ...upply voltage of 12 V single power rail voltage and a wide input voltage range of 8 5 V to 20 V Other supported voltages are 5 V standby and 3 3 V RTC battery input Table 5 COM bV26 Electrical Specifi...

Page 27: ...s are available within the BIOS set up menu Advance ACPI Settings 2 4 2 1 Suspend States If power is removed 5 V can be applied to the V_5V_STBY pins to support the ACPI suspend states Suspend to RAM...

Page 28: ...urpose wake up signal Wake 1 Suspend Control SUS_STAT B18 SUS_STAT indicates an imminent suspend operation Used to notify LPC devices After a complete power loss including battery voltage there is an...

Page 29: ...he module from S5 state press the power button or reconnect VCC Table 8 Single Power Supply Mode Settings State PWRBTN PWR_OK V5_Standby VCC G3 0V x 1 0V x 1 0V x 1 0V x 1 S5 high open high open VCC S...

Page 30: ...be used with the heatspreader plate The optimum cooling solution depends on the COM Express application and environmental conditions Kontron s active or passive cooling solutions are designed to cover...

Page 31: ...inearity The thermal resistors give a general indication of the ambient temperature close to the processor These differences are due to the design and are not to be considered as an error The on modul...

Page 32: ...tor 3 Pin Pin Assignment Pin Signal Description Type 1 Fan_Tach_IN Fan input voltage from COMe connector Input 2 V_FAN 12 V 10 max across module input range PWR 3 GND Power GND PWR If the input voltag...

Page 33: ...ntal Description Commercial Grade Operating 0 C to 60 C 32 F to 140 F Non operating 30 C to 85 C 22 F to 185 F Extended Grade E1 Operating 25 C to 75 C 13 F to 167 F Non operating 30 C to 85 C 22 F to...

Page 34: ...ry Compliance USA CANADA Safety UL 62368 1 CSA C22 2 No 62368 1 Component Recognition Audio video information and communication technology equipment Part 1 Safety requirements Recognized by Underwrite...

Page 35: ...bility report article number 38036 0000 30 6 The MTBF estimated value above assumes no fan but a passive heat sinking arrangement Estimated RTC battery life as opposed to battery failures is not accou...

Page 36: ...4 9 Figure 7 Module Dimensions All dimensions are in mm 2 8 2 Module Height The COM Express specification defines a module height of approximately 13 mm when measured from the bottom of the module s P...

Page 37: ...Module PCB board 3 Carrier PCB board 4 Heatspreader standoff s 5 Connector standoff s 5 mm or 8 mm 6 13 mm 0 65 mm 2 8 3 Cooling Concept Dimensions Thermal paste is used to enhance heat transfer away...

Page 38: ...e and the external I2C bus transfers between I2C devices connected on the bus The fast I2C bus transfers data with transfer rates up to 400 kHz To change the I2C bus speed in the BIOS setup menu selec...

Page 39: ...d keep time using a lower secondary source of power while the primary source of power is switched off or unavailable Typical RTC values are 3 V and less than 10 A When powered by mains power supply th...

Page 40: ...the external SPI Flash chip on the carrier board with the BIOS binary use an external programmer Register for Kontron s Customer Section to get access to BIOS downloads and PCN service To boot either...

Page 41: ...X and A99 SERO_RX for UART0 and pins A101 SER1_TX and A102 SER1_RX for UART1 The UART option is 16550 compatible and features 64 byte TX RX host controller FIFOs On chip bit rate baud rate generator P...

Page 42: ...Express pin B27 on COM Express connector indicates a Watchdog time out event has not been triggered within a set time The WDT signal is configurable to any of the two stages After reset the signal is...

Page 43: ...Internally reserved No A0h 50h Module embedded EEPROM Eeep Yes AEh 57h Carrier board EEPROM Option 64h 32h External RTC Option 4 2 System Management SM Bus The 8 bit SMBus address uses the LSB bit 0...

Page 44: ...mm or 8 mm depends on the height of the carrier board s connector The module is powered on by connecting to the carrier board using the interface connector Before connecting the module s interface con...

Page 45: ...For more information contact Kontron Support Table 21 General Signal Description Type Description Type Description NC Not Connected on this product O 1 8 1 8 V Output I O 3 3 Bi directional 3 3 V I O...

Page 46: ...ink LED OD A9 GBE0_MDI1 Ethernet Media Dependent Interface 1 DP I O A10 GBE0_MDI1 Ethernet Media Dependent Interface 1 DP I O A11 GND_A11 Power Ground PWR GND A12 GBE0_MDI0 Ethernet Media Dependent In...

Page 47: ...tegrated PD 14 25K to 24 8K A40 USB4 USB 2 0 Data Pair Port 4 DP I O Integrated PD 14 25K to 24 8K A41 GND_A41 Power Ground PWR GND A42 USB2 USB 2 0 Data Pair Port 2 DP I O Integrated PD 14 25K to 24...

Page 48: ...ane 1 Transmit DP O AC Coupled on Module A65 PCIE_TX1 PCI Express Lane 1 Transmit DP O AC Coupled on Module A66 GND_A66 Power Ground PWR GND A67 GPI2 General Purpose Input 2 I 3 3 PU 100k 3 3V S0 A68...

Page 49: ...lave OUT I 3 3 A93 GPO0 General Purpose Output 0 O 3 3 PD 100k A94 SPI_CLK SPI Clock O 3 3 A95 SPI_MOSI SPI Master Out Slave In O 3 3 A96 TPM_PP TPM Physical Presence I 3 3 PD 10K TPM does not use thi...

Page 50: ...n Type Termination Comment A107 VCC_12V_A107 Main Input Voltage 8 5 20V PWR 8 5 20V A108 VCC_12V_A108 Main Input Voltage 8 5 20V PWR 8 5 20V A109 VCC_12V_A109 Main Input Voltage 8 5 20V PWR 8 5 20V A1...

Page 51: ...3 I O 3 3 PU S0 SKU B8 LPC_DRQ0 ESPI_ALERT0 LPC Serial DMA Master Request 0 eSPI Alert 0 I 3 3 PU 10k 3 3V SO B9 LPC_DRQ1 ESPI_ALERT1 Not connected NC B10 LPC_CLK ESPI_CK 24MHz LPC clock O 3 3 33MHz B...

Page 52: ...Data Pair Port 5 DP I O PD 14 25k to 24 8k B41 GND_B41 Power Ground PWR GND B42 USB3 USB 2 0 Data Pair Port 3 DP I O PD 14 25k to 24 8k B43 USB3 USB 2 0 Data Pair Port 3 DP I O PD 14 25k to 24 8k B44...

Page 53: ...B DAT0 DP O B73 LVDS_B1 LVDS Channel B DAT1 DP O B74 LVDS_B1 LVDS Channel B DAT1 DP O B75 LVDS_B2 LVDS Channel B DAT2 DP O B76 LVDS_B2 LVDS Channel B DAT2 DP O B77 LVDS_B3 LVDS Channel B DAT3 DP O B7...

Page 54: ...Reserved for future use NC B100 GND_B100 Power Ground PWR GND B101 FAN_PWMOUT Fan PWM Output O 3 3 20V protection circuit implemented on module PD on carrier board needed for proper operation B102 FA...

Page 55: ...DP I O C14 GND_C14 Power Ground PWR GND C15 DDI1_PAIR6 Digital Display Interface Pair 6 NC C16 DDI1_PAIR6 Digital Display Interface Pair 6 NC C17 RSVD_C17 Reserve for future use NC C18 RSVD_C18 Reser...

Page 56: ...1 Reserve for future use NC C46 DDI3_PAIR2 Digital Display Interface Pair 2 DP O C47 DDI3_PAIR2 Digital Display Interface Pair 2 DP O C48 RSVD_C48 1 Reserve for future use NC C49 DDI3_PAIR3 Digital Di...

Page 57: ...DP I C72 PEG_RX6 PCI Express Graphics Receive Input differential pairs DP I C73 GND_C73 Power Ground PWR GND C74 PEG_RX7 PCI Express Graphics Receive Input differential pairs DP I C75 PEG_RX7 PCI Exp...

Page 58: ...ure use NC C98 PEG_RX14 PCI Express Graphics Receive Input differential pair NC C99 PEG_RX14 PCI Express Graphics Receive Input differential pairs NC C100 GND_C100 Power Ground PWR GND C101 PEG_RX15 P...

Page 59: ...CTRLCLK AUX I O 3 3 PD 100K D16 DDI1_CTRLDATA_A UX DDI1 CTRLDATA AUX I O 3 3 PU 100K 3 3V S0 D17 RSVD_D17 1 Reserved for future use NC D18 RSVD_D18 1 Reserved for future use NC D19 PCIE_TX6 PCIE Expr...

Page 60: ...ay Interface Pair 2 DP O D48 RSVD_D48 1 Reserve for future use NC D49 DDI2_PAIR3 Digital Display Interface Pair 3 DP O D50 DDI2_PAIR3 Digital Display Interface Pair 3 DP O D51 GND_D51 Power Ground PWR...

Page 61: ...ics Transmit Output differential pairs DP O D76 GND_D76 Power Ground PWR GND D77 RSVD_D77 1 Reserve for future use NC D78 PEG_TX8 PCI Express Graphics Transmit Output differential pairs NC D79 PEG_TX8...

Page 62: ...press Graphics Transmit Output differential pairs NC D100 GND_D100 Power Ground PWR GND D101 PEG_TX15 PCI Express Graphics Transmit Output differential pairs NC D102 PEG_TX15 PCI Express Graphics Tran...

Page 63: ...appear on the screen POST messages or splash screen 3 Press the DEL key 4 If the uEFI BIOS is password protected a request for password will appear Enter either the User Password or the Supervisor Pas...

Page 64: ...window The help window provides an explanation of the respective function 6 4 Setup Menus The Setup utility features a selection bar at the top of the screen that lists the available Setup menus for t...

Page 65: ...BIOS vendor Core version Compliancy Project Version Build Date and Time and Access level Memory Information Read only field Total memory System Language English Platform Information Read only field D...

Page 66: ...ble 28 Advanced Setup Menu Sub screens and Functions Sub Screen Function Second level Sub Screen Description Trusted Computing Security Device Support BIOS support for security devices OS will not sho...

Page 67: ...sable ACPI Settings Enable ACPI Auto Configuration Enable Disable Enable Hibernation System ability to hibernate OS S4 sleep state Note May not be effective with some operating systems Enable Disable...

Page 68: ...Sets fan control mode Note disable totally stops fan Auto Disabled Manual Fan Pulse Number of pulses the fan produces during one revolution range 1 to 4 2 Fan Trip Point Temperature where the fan acc...

Page 69: ...e protection function Enabled Disabled SVM Mode CPU Virtualization Enabled Disabled Node 0 Information Read only Socket Core s Processor Family Processor Model CPUID Current Speed Min Speed Microcode...

Page 70: ...e system Option ROM Dispatch Policy Restore if Failure If system fails to boot and this option is set to enabled software resets settings of this page as well as CSM page to the default values automat...

Page 71: ...USB Transfer Time out Timeout value for control bulk and interrupt transfers 1 sec 5 sec 10 sec 20 sec Device Reset Time out USB mass storage device start unit command time out 10 sec 20 sec 30 sec 4...

Page 72: ...rm First Error Handling PFEH Cloak individual banks and mask deferred error interrupts from each bank Enabled Disabled Auto Core Performance Boost Disable CP8 Disabled Auto Global C State Control Cont...

Page 73: ...1 kB 2kB Auto DRAM Map Inversion Inverting causes the highest memory channels to get assigned the lowest system addresses Enabled Disabled Auto CC6 Memory Region Encryption Controls is CC6 save resto...

Page 74: ...rer s warranty DRAM Controller Configuration DRAM Power Options Power Down Enable Enabled Disabled Auto Cmd2T 1T 2T Auto Gear Down Mode Enabled Disabled Auto LPDDR4 Refresh Mode Auto All Banks per Ban...

Page 75: ...apping Chip select Interleaving Disabled Auto BankGroupSwap Disabled Auto CPU Mode APU Mode ALT Mode Address Hash Bank Enabled Disabled Auto Address Hash CS Enabled Disabled Auto Address Hash Rm Enabl...

Page 76: ...p Step Size 1 2 4 Write Voltage Sweep Step Size 1 2 4 Write Timing Sweep Step Size 1 2 4 NBID Common Options IOMMU Enabled Disabled Auto PCIe ARI Support Enabled Disabled Auto PSPP Policy Enabled Disa...

Page 77: ...rning Selecting System Configuration may cause system to hang as some system configurations may not be supported by your OPN CPPC Enable override Disable set default Enabled Disabled Auto FCH Common O...

Page 78: ...s to legacy address 0x2E8 0x2F8 0x3E8 0x3F8 UART Driver Type AMD UART Driver AMD Serial Driver LPC Options LPC Clock Run Control Enabled Disabled Auto SoC Miscellaneous Control ABL Console Out Control...

Page 79: ...Support Enabled Disabled Discrete GPU HPD Circuitry OR Circuitry Pulse Circuitry Discrete GPU Audio Disabled Keep ROM Strap Setting Discrete GPU BOMACO Support Enabled Disabled Primary Video Adapter...

Page 80: ...PASS Enabled Disabled S3 Modern Standby Support S3 Enable Modern Standby Enable Modern Standby Type Modern Standby SOI2 Modern Standby SOI3 Modern Standby SOI2 SOI3 Reduce Hardware Support Enabled Dis...

Page 81: ...Raw Size The valid RAM disk size should be multiples of the RAM disk block size 1 Create and Exit Discard and Exit Create from File Create a RAM Disk from a given File Created RAM Disk List RAM Disk 0...

Page 82: ...Functions Function Second level Sub Screen Description South Bridge SB USB Configurtion XHCI0 Port 0 Enabled Disabled XHCI0 Port 1 Enabled Disabled XHCI0 Port 2 Enabled Disabled XHCI0 Port 3 Enabled D...

Page 83: ...State Capability Enabled Disabled Auto SATA MSI Capability Support Enabled Disabled Auto SATA Target Support 8 Devices Enabled Disabled Auto Generic Mode Enabled Disabled Auto SATA AHCI Enclosure Enab...

Page 84: ...WXGA 1440x900 2x24 SXGA 1280x1024 2x18 SXGA 1280x1024 2x24 WSXGA 1680x1050 2x18 WSXGA 1680x1050 2x24 UXGA 1600x1200 2x18 UXGA 1600x1200 2x18 WUXGA 1920x1200 2x18 WUXGA 1920x1200 2x18 FHD 1920x1080 2x1...

Page 85: ...cription Administrator Password Sets administrator password User Password Sets user password Secure Boot Enabled Disabled Secure Boot Mode Custom Standard Restore Factory Keys Force System to user mod...

Page 86: ...ot mode Enroll SHA256 Hash certificate of a PE image into Authorized Signature Database Device Guard Ready Remove UEFI CA from DB Restore DB Defaults Restore DV variable to factory default Secure Boot...

Page 87: ...p Menu Sub screens and Functions Function Description Setup Prompt Timeout 1 Bootup NumLock State On Off Quiet Boot Enabled Disabled Boot Option Priorities Boot Option 1 UEFI Built in EFI Shell Disabl...

Page 88: ...system after saving changes Discard Changes and Exit Exits system setup without saving changes Save Changes and Reset Resets system after saving changes Discard Changes and Reset Resets system setup...

Page 89: ...ult 6 5 1 Entering the uEFI Shell To enter the uEFI Shell follow the steps below 1 Power on the board 2 Press the F7 key instead of DEL to display a choice of boot devices 3 Select UEFI Built in EFI s...

Page 90: ...nder any OS with a plain text editor of your choice To create a startup shell script simply save the script on the root of any FAT formatted drive attached to the system To copy the startup script to...

Page 91: ...re modifications Addition connected hardware full description of hardware set up The serial number can be found on the Type Label Be ready to explain the nature of your problem to the service technici...

Page 92: ...n Europe GmbH Deggendorf and fill out the form Take care to include a short detailed description of the observed problem or failure and to include the product identification Information Name of produc...

Page 93: ...ard Disk Drive HDMI High Definition Multimedia Interface HWM Hardware Monitor I2 C Inter integrated Circuit Communications ICM Integrated Connector Module IOT Internet of Things ISA Industry Standard...

Page 94: ...andard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result cu...

Reviews: