KBox B-201-CFL - User Guide, Rev 1.3
// 35
7.2.
Minimum System Clearance (Keep out Area)
To provide maximum airflow through and around the KBox B-201-CFL, a minimum distances to the surrounding
environment must be observed know as keep out area in this user guide. Before installing the KBox B-201-CFL, ensure
that the keep out areas (see Figure 23 and Figure 24) have been taken into consideration.
Leave sufficient clearance (keep out area) to prevent the product from overheating!
To ensure proper operation use the specified recommended keep out areas of :
•
Top cover: 10 mm (0.394")
•
Left and right sides: 10 mm (0.394")
•
Front and rear panel: 10 mm (0.394")
•
Bottom side: (no restriction)
7.3.
Third Party Components
When configured with third party components such as mPCIe expansion cards, M.2 modules and hard drives
(HDD/SSD), the air temperature inside the product is higher than the ambient temperature. An approximate internal
temperature rise is given.