3.5"-SBC-VR1000 - User Guide, Rev. 1.7
// 57
7.17.2.
Backlight Enable Selection (JP2)
The 2.0 mm patch "Backlight Enable Selection" jumper (JP2) can be used to select voltage level of backlight enable
signal.
Figure 32: Backlight Enable Selection JP2
Table 39: Pin Assignment JP2
Jumper 1 Position
Description
Pin 1-3
Pin 3-5
X
-
Backlight Enable Level = +3.3 V
-
X
Backlight Enable Level = +5 V
Jumper 2 Position
Description
Pin 2-4
Pin 4-6
X
-
Backlight Enable High Active
-
X
Backlight Enable Low Active
“
X’’ = Jumper set (short) and ‘‘-’’ = jumper not set (open)
2
1
6
5