Circuit Board 

 

 

 

1.

 

POWER (LNE) 

An electrical supply should be supplied to the sensor. (100-240VAC) 
This should be externally fused at 3 Amps and connected to these terminals. 
 

2.

 

TO VALVE (LNE)

 

The gas solenoid valve should be powered using these terminals. 

 

7

 

Power On & Off 

How to turn your device ON 

 

Supply 240vAC mains to the [L N E POWER IN] terminal.  

 

Press RESET button.  

 
How to turn your device
 OFF 

 

Remove or switch off the mains power supply. 

 

8

 

LED Status 

 

Power LED  

When the system is connected to the power supply, the Green Power LED will illuminate.  

 

Methane LED 

When the gas detector has reached alarm state for Methane, this will illuminate Red.  
To reset Alarm press RESET button. 

 

CO LED 

When gas is detected, this will flash Red. If gas is exposed for pre-defined time – the Red LED will 

remain ON. To reset the Alarm press RESET button. 

 

Summary of Contents for Merlin CH4CO

Page 1: ...Merlin CH4CO User Guide Rev 07 05 19 1 Gas Safety Products Merlin CH4CO Dual Gas Sensor Methane Carbon Monoxide User Guide Please read this guide carefully and retain for future use...

Page 2: ...n 3 2 Carbon Monoxide CO General Information 4 3 Methane Natural Gas NG General Information 5 4 Technical Specification 6 5 Installation Location 6 6 Circuit Board 7 7 Power On Off 7 8 LED Status 7 Po...

Page 3: ...is NOT designed to detect smoke fire or other gases and should NOT be used as such Never ignore your device when in alarm This device requires a continual supply of electrical power it will not work w...

Page 4: ...isplay that shows levels of CO displayed in PPM parts per million Dangerous levels Generally above 100ppm This should be treated as an urgent situation Medium levels Generally between 50ppm to 100ppm...

Page 5: ...proper ventilation can produce carbon monoxide a deadly gas that is difficult to detect SYMPTOMS OF METHANE EXPOSURE Methane gas is relatively non toxic and associated with being a simple asphyxiator...

Page 6: ...location of the holes needed on the wall using the back plate as a template Placing at eye level allows for optimum monitoring of the digital display screen or as guide 5 foot 1 5 meters from ground...

Page 7: ...pply 240vAC mains to the L N E POWER IN terminal Press RESET button How to turn your device OFF Remove or switch off the mains power supply 8 LED Status Power LED When the system is connected to the p...

Page 8: ...o the implied warranties of description merchantability and intended operational purpose are limited in duration to the above warranty period In no event shall the manufacturer be liable for loss of u...

Reviews: