background image

INSTALLATION, OPERATION & MAINTENANCE MANUAL

ENERGY RECOVERY VENTILATOR

 

TRC500

 

WWW.SOLERPALAU-USA.COM

Summary of Contents for TRC500

Page 1: ...INSTALLATION OPERATION MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR TRC500 WWW SOLERPALAU USA COM ...

Page 2: ...ilation Group is the world s leading fan manufacturer It celebrated its 50th anniversary in 2001 Soler Palau is able to offer a range of ventilation products benefiting from over 50 years of experience within the industry The company s impressive long term growth is the result of one simple philosophy develop an air moving product that effectively and efficiently meets the needs of the customer su...

Page 3: ...lbs in carton 193 lbs on pallet up to 3 units on 40 lb pallet Shipping Dimensions 48 L x 41 W x 18 H in carton 55 L x 42 W x 22 H on pallet Volts HZ Phase FLA Min Cir Amps Max Overcurrent Protection Device 115 60 Single 7 2 9 0 15 208 230 60 Single 3 9 3 6 4 9 15 Airflow CFM ESP in H2 0 Watts 1P Temp EFF Total EFF Winter Summer 225 1 25 335 79 75 64 338 1 00 420 75 70 59 380 0 90 470 74 69 58 450 ...

Page 4: ...ERV TRC500 1 800 961 7370 INSTALLATION OPERATION AND MAINTENANCE MANUAL WWW SOLERPALAU USA COM 4 TRC500 INFO PRODUCT DIMENSIONS TRC500 ...

Page 5: ...for safe installation of the unit For maximum air performance minimize the number of elbows and do not place elbows within three feet of the TRC500 s discharges For applications where duct noise is a critical issue use noise attenuating techniques such as duct isolation insulation and proper duct design per SMACNA or ASHRAE standards Provide Adequate Service Access for Maintenance The TRC500 will ...

Page 6: ... into insulation Build up of moisture can result in failure of the duct system and or frost in the insulation Make sure any tears in the inner and outer vapor barriers are sealed CAUTION DUCTS TO THE OUTSIDE The TRC500 requires four ducts Exhaust Air Duct insulated duct from unit to outside Outside Air Duct insulated duct from outside to unit Room Air Duct from room to unit Fresh Air Duct from uni...

Page 7: ...ach space If air is regularly mixed by the heating cooling system one room air pick up and one fresh air supply may be all that is needed Connecting to an existing air circulation system It is often convenient and effective to connect the Fresh Air duct from the TRC500 to a return duct of an existing heating cooling system This way whenever the heating cooling system is running fresh air from the ...

Page 8: ...ng into wall or ceiling do not damage electrical wiring and other hidden utilities 10 This unit must be properly ducted to the out doors RISK OF FIRE ELECTRIC SHOCK OR INJURY OBSERVE ALL CODES AND THE FOLLOWING WARNING Take these simple steps to attenuate noise from the unit OUTSIDE THE BUILDING Exhaust velocity noise is the primary cause of unit related noise outside the building Size the exhaust...

Page 9: ...GLE PHASE UNIT STANDARD WIRING SCHEMATICS CHANGES NAME REV DATE S P A B C D E New 1 8 3 2018 austine 130154_001 TRC 500 Input Power 115 VAC 1 Phase 208 230 VAC 1 Phase M1 N L2 L1 GND Contactor 24 VAC A1 A2 1L1 3L2 2T1 4T2 Transformer COM 24V Circuit Breaker Relay 24 VAC 13 14 8 12 4 BK BK RD BU BK BK RD BU BU YL YL YL RD OR ...

Page 10: ...e removed The TRC500 weighs approximately 135 lbs It is the installer s responsibility to make sure that the screws or bolts used for securing the units are properly selected for the loads and substrates involved Secure the TRC500 so that it cannot fall or tip in the event of accident structural failure or earthquake Do not stand on the unit Do not stack or store items on the unit when installed T...

Page 11: ...convient pas pour utilisation avec regulateur de vitesse electronique Moteursd unephasedel ECMneconviennentpaspour une utilisation avec regulateur de vitesse electronique Ils ont déjà le contrôle de vitesse intégré dans le moteur électronique NOTE Standard TRC500 with single phase original equipment motors are suitable for use with solid state speed control Le TRC500 avec moteurs d équipement d or...

Page 12: ... by removing two or three screws Connect the units power field wiring to the terminals of the disconnect switch 4 Connect service ground to ground wire pigtail 5 Connect the control system to the pigtails in the control voltage compartment of the units electrical box Make sure you are connecting the correct voltage 24VAC to the control pigtails See Control Wiring Schematics Before bringing power t...

Page 13: ...ics and connect the external power only to the specified terminals in order to avoid damaging the unit or external controls Connect only CLASS II power to the control terminals of this unit 5 Unit is not equipped to receive analog signals such as 1 10vdc or 4 20mA 6 Unit is not equipped to communicate directly with Building Management Systems such as BACNET LONWORKS etc However the unit can be con...

Page 14: ...lue lead Connect the switched output of the Control to the red lead to operate the ERV s isolation relay B Control Sending 24VAC On Signal from an external power source to ERV Make sure the blue and red leads are separately capped and not connected to any other wires Now you safely can apply 24VAC to the two yellow leads to operate the ERV s isolation relay Be careful if the external control syste...

Page 15: ...ate pressure ports To read SCFM of Fresh Air FA install the high pressure side of your measuring device to the Outside Air OA port and the low pressure side to the Fresh Air FA port To read SCFM of Room Air RA install the high pressure side of your measuring device to the Room Air RA port and the low pressure side to the Exhaust Air EA port Use the reading displayed on your measurement device to c...

Page 16: ...ize 13 5 x 19 5 x 1 75 Unit shipped with MERV 8 Filters Minimum recommended effectiveness MERV 6 MEASURING AIR FLOW Pleated_Filter_PD_AUG17 14x20x2 MERV 8 IOM 0 0 0 1 0 2 0 3 0 4 200 300 400 500 600 Clean filter Pressure Drop in w g Unit Airflow CFM Initial Pressure Drop of MERV 8 Filters supplied with this unit INITIAL PRESSURE DROP OF MERV 8 FILTERS SUPPLIED WITH THIS UNIT ...

Page 17: ...ERV TRC500 17 1 800 961 7370 INSTALLATION OPERATION AND MAINTENANCE MANUAL WWW SOLERPALAU USA COM TRC500 SERVICE PARTS MAINTENANCE www renewaire com 800 627 4499 support renewaire com ...

Page 18: ...S Keep your ERV performing at its best by cleaning it as described below TO CLEAN THE ENERGY EXCHANGE ELEMENT Vacuum the face of the energy exchange element yearly Dust collects only on the entering face of the energy exchange element right where the filter sits The interior of the energy exchange element stays clean even if the element faces are dust covered 1 Remove the filters see below 2 Vacuu...

Page 19: ...ERV TRC500 19 1 800 961 7370 INSTALLATION OPERATION AND MAINTENANCE MANUAL WWW SOLERPALAU USA COM NOTES ...

Page 20: ...18 USA 800 961 7370 FAX 800 961 7379 6393 POWERS AVE JACKSONVILLE FLORIDA 32217 USA WWW SOLERPALAU USA COM CANADA 416 744 1217 FAX 416 744 0887 5600 AMBLER DRIVE MISSISSAUGA ON L4W 2K9 CANADA WWW SOLERPALAUCANADA COM ...

Reviews: