WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

4. Please read specification label on product for further information and requirements.

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush 

attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the 

exact service motor. The impeller should also be replaced.

See “ELECTRICAL WIRING” for wiring and switch details.

VENTILATION FAN

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power 

from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and 

standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to 

prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the 

National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning   Engineers 

(ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit 

(ceiling installation only). 

h). This unit must be grounded. 

i). Not for Use in Kitchens.

j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or 

ceilings or into attics, crawl spaces, or garages

k).  WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.

MODEL:  PCD110XP

Cod: 0060302596

*The manual in electronic format can be download in our company web, or obtained from our dealer.

T

H

S

Max.

OFF

30

CFM

60%

50%

80%

75%

85%

100%

60min

20min

40min

OFF

OFF

5min

 Humidity

 sensor knob

Time delay 

knob

Switch 

position

Airflow (CFM)

80

1 2

110

1 2

140

1 2

Low airflow

 knob

Toggle switch

The control box, located inside the fan housing, has four settings:

(1) The toggle switches set the fan high speed from 80 to 140 CFM (factory set to 110 CFM). 

The fan will run at high speed when switch II is turned ON.

(2) The time delay knob sets the amount of time that the fan will continue to run at high speed 

after switch II is turned OFF, or motion is detected (if enabled), or the RH% limit is reached 

(if enabled). It is adjustable from 5 to 60 minutes. Once the set time has elapsed, the fan will 

run at the low airflow knob setting (low speed). The time delay setting is de-activated when 

set between OFF-5 mins (factory set to OFF). NOTE: for humidity sensing applications, the 

fan will continue to run for 5 minutes after humidity is below the RH% limit, even if the time 

delay knob is set between OFF-5 mins.

(3) The low airflow knob (low speed) sets the low airflow from 30 CFM up to the high speed 

airflow rate. The low speed is de-activated when set between OFF-30 CFM (factory set to 

OFF). The fan will run at low speed when switch I is turned ON and humidity is below the 

RH% limit (if enabled), and motion is not detected (if enabled).

(4) The humidity sensor knob sets the RH% limit at which the fan will automatically operate at 

high speed. The humidity sensor is de-activated when set between OFF-50% (factory set to 

OFF).

Summary of Contents for PCD110XP

Page 1: ...r ceiling do not damage electrical wiring and other hidden utilities f Ducted fans must always be vented to the outdoors g Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit ceiling installation only h This unit must be grounded i Not for Use in Kitchens j To reduce risk of fire and to properly exhaust air be sure to duct air ...

Page 2: ... if enabled are OFF completely HUMIDITY SENSOR OPERATION The fan runs continuously at a low speed if enabled set by the low airflow knob and automatically boosts up to high speed when the relative humidity RH in the room exceeds the RH limit set with the humidity sensor knob If the fan continuously responds to changing environmental conditions too sensitive the RH limit may need to be adjusted SEN...

Page 3: ...y to the fan housing pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots Push the grille assembly towards the ceiling to secure OPTIONAL MOTION OR LIGHTED MOTION SENSING GRILLE Insert the plug from the sensor system into the power box Attach the wire to the blower To attach the grille assembly to the...

Page 4: ...ng out of or in connection with product use or performance This warranty gives you specific legal rights You may also have other rights which vary from state to state To qualify for warranty service you must notify S P at the address or telephone number stated below provide the model number and part identification and describe the nature of any defect in product or part You may be required to ship...

Reviews: