WARNING
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
CAUTION
CLEANING & MAINTENANCE
OPERATION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush
attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the
exact service motor. The impeller should also be replaced.
See “ELECTRICAL WIRING” for wiring and switch details.
VENTILATION FAN
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power
from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit
(ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces, or garages
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.
MODEL: PCD110XP
Cod: 0060302596
*The manual in electronic format can be download in our company web, or obtained from our dealer.
T
H
S
Max.
OFF
30
CFM
60%
50%
80%
75%
85%
100%
60min
20min
40min
OFF
OFF
5min
Humidity
sensor knob
Time delay
knob
Switch
position
Airflow (CFM)
80
1 2
110
1 2
140
1 2
Low airflow
knob
Toggle switch
The control box, located inside the fan housing, has four settings:
(1) The toggle switches set the fan high speed from 80 to 140 CFM (factory set to 110 CFM).
The fan will run at high speed when switch II is turned ON.
(2) The time delay knob sets the amount of time that the fan will continue to run at high speed
after switch II is turned OFF, or motion is detected (if enabled), or the RH% limit is reached
(if enabled). It is adjustable from 5 to 60 minutes. Once the set time has elapsed, the fan will
run at the low airflow knob setting (low speed). The time delay setting is de-activated when
set between OFF-5 mins (factory set to OFF). NOTE: for humidity sensing applications, the
fan will continue to run for 5 minutes after humidity is below the RH% limit, even if the time
delay knob is set between OFF-5 mins.
(3) The low airflow knob (low speed) sets the low airflow from 30 CFM up to the high speed
airflow rate. The low speed is de-activated when set between OFF-30 CFM (factory set to
OFF). The fan will run at low speed when switch I is turned ON and humidity is below the
RH% limit (if enabled), and motion is not detected (if enabled).
(4) The humidity sensor knob sets the RH% limit at which the fan will automatically operate at
high speed. The humidity sensor is de-activated when set between OFF-50% (factory set to
OFF).