MULTI-REG CONTROL IP54

 

Summary of Contents for MULTI-REG CONTROL 2841 Series

Page 1: ...Page 1 of 24 MULTI REG CONTROL IP54 ...

Page 2: ...Page 2 of 24 ...

Page 3: ...TCHED 230V SUPPLY 10 6 3 CONTINUOUS RUNNING WITH TWO OPTIONAL SPEEDS VIA EXTERNAL VOLT FREE CONTACTS 11 6 4 CONTINUOUS RUNNING WITH TWO OPTIONAL SPEEDS VIA EXTERNAL SWITCHED 230V SUPPLY 12 6 5 REMOTE ENABLE AND SPEED CONTROL VIA EXTERNAL REB ECOWATT 13 6 6 REMOTE ENABLE AND SPEED CONTROL VIA EXTERNAL REB CVF 14 6 7 CONTINUOUS RUNNING WITH TWO OPTIONAL SPEEDS VIA EXTERNAL SWITCHED 230V SUPPLY 15 6 ...

Page 4: ...Page 4 of 24 ...

Page 5: ...y if the apparatus is not in its original packaging or shows clear signs of having been manipulated in any way Do not place heavy weights on the packed product and avoid knocking or dropping it When handling heavy products adequate lifting equipment should be used to avoid harming people or damaging the product itself Never lift a product by pulling it by the wires or terminal control enclosure Li...

Page 6: ...onitoring system to allow full airflow to develop 3 5 Outputs Digital Display Running Stopped and or fault condition Fan speed percentage and 0 10V output condition Countdown to fault status monitoring condition allows fan to gain speed Diagnostic Reasons for fan stop fail 3 6 Analog Switch Outputs Output to BMS of fan run and fault indicated by an individual set of contacts capable of controlling...

Page 7: ...s access to the terminals and mounting holes that are under the lid The connections must be as shown in the applicable wiring diagram Should the current rating of the fuse in the controller exceed that of the wiring of the fan s circuit s each fan should be protected independently If individual protection for each fan is being employed then this should be situated in each common line only The cont...

Page 8: ...Neutral E Earth Fault monitoring Tacho To monitor the status of fan change TACHO jumpers from OFF to ON If you are using FAN 1 O P change TACHO 1 to ON If you are using FAN 2 O P change TACHO 2 to ON NOTE If the fan does not have a tacho output then the jumper should remain in the OFF Position ...

Page 9: ...NTROL WIRING 6 1 REMOTE ENABLE VIA EXTERNAL VOLT FREE CONTACT Fan speed set point Min Speed The speed is defined by the Min speed Potentiometer by rotating the potentiometer dial it will change the set speed of the fan ...

Page 10: ... 24 6 2 REMOTE ENABLE VIA EXTERNAL SWITCHED 230V SUPPLY Fan speed set point Min Speed The speed is defined by the Min speed Potentiometer by rotating the potentiometer dial it will change the set speed of the fan ...

Page 11: ...ating the potentiometer dial it will change the set speed of the fan Optional second speed Mid Speed The speed is defined by the Mid speed Potentiometer by rotating the potentiometer dial it will change the set speed of the fan Optional third speed High Speed The speed is defined by the High speed Potentiometer by rotating the potentiometer dial it will change the set speed of the fan ...

Page 12: ...tating the potentiometer dial it will change the set speed of the fan Optional second speed Mid Speed The speed is defined by the Mid speed Potentiometer by rotating the potentiometer dial it will change the set speed of the fan Optional third speed High Speed The speed is defined by the High speed Potentiometer by rotating the potentiometer dial it will change the set speed of the fan ...

Page 13: ...ONTROL VIA EXTERNAL REB ECOWATT PRIOR TO ENERGISING THE MULTI REG THE INSTALLER MUST SET ALL THREE OF THE SPEED POTENTIOMETERS TO THEIR MINIMUM FULLY ANTI CLOCKWISE POSITION Fan speed The speed is defined by rotating the dial on the REB ECOWATT ...

Page 14: ...ED CONTROL VIA EXTERNAL REB CVF PRIOR TO ENERGISING THE MULTI REG THE INSTALLER MUST SET ALL THREE OF THE SPEED POTENTIOMETERS TO THEIR MINIMUM FULLY ANTI CLOCKWISE POSITION Fan speed The speed is defined by rotating the dial on the REB CVF ...

Page 15: ...0V SUPPLY PRIOR TO ENERGISING THE MULTI REG THE INSTALLER MUST SET ALL THREE OF THE SPEED POTENTIOMETERS TO THEIR MINIMUM FULLY ANTI CLOCKWISE POSITION Fan speed 0 10V The speed is defined by the highest voltage of the two 0 10V signals from the external devices the minimum output is 3V ...

Page 16: ... of 24 6 8 REMOTE ENABLE VIA 7 DAY TIMER 1000001114 Fan speed set point Min speed The speed is defined by the Min speed Potentiometer by rotating the potentiometer dial it will change the set speed of the fan ...

Page 17: ...relay Maximum current load 8A Fan Running Continuity between COM and NO Fan Stopped Continuity between COM and NC Fault relay Maximum current load 8A Fan Running Stopped Continuity between COM and NC Fault with Fan Continuity between COM and NO ...

Page 18: ...ignifying loss of airflow the controller will automatically stop the fan and display EXTERNAL SW1 FAULT Following an EXTERNAL SW1 FAULT a manual re start will be required External fire shut off switch SW2 When the fan is in normal running conditions the switch should be in the closed position When the fault switch opens signifying the fire alarm has been activated the controller will automatically...

Page 19: ...Page 19 of 24 6 11 DAMPER Damper actuator When the fan is running the damper opens When the fan is stopped intentionally or in a fault condition the damper s spring return facility closes the damper ...

Page 20: ...the Timer potentiometer this will allow you to add an over run of 0 to 15 minutes the over run function will operate for both remote enable and boost functions If a 10 minute over run is set then the remote enable will over run for 10 minutes and the boost will over run for 10 minutes ...

Page 21: ...output by 3V or 3V this is limited by the minimum output 3V and maximum output 10V If a 7V supply is required by fan 1 and a 4V supply is required by fan 2 then you will alter the Off set Output 2 potentiometer anti clockwise If a 7V supply is required by fan 1 and a 10V supply is required by fan 2 then you will alter the Off set Output 2 potentiometer clockwise ...

Page 22: ...ding recycling containers and hand in the replaced machines to the nearest handler of this type of waste product If you have any queries about S P products please contact our after sales service at your local S P dealer If in doubt please visit our website at www solerpalau co uk 9 EC DECLARATION OF CONFORMITY Herewith we declare that the fan control designated below on the basis of its design and...

Page 23: ...andards and national and local building standards IF CLAIMING UNDER WARRANTY Please return the completed product carriage paid to your local authorized distributor All returns must be accompanied by a valid Invoice of Sale All returns must be clearly marked Warranty Claim with an accompanying description stating the nature of the fault THE FOLLOWING WARRANTIES DO NOT APPLY Damages resulting from i...

Page 24: ...Page 24 of 24 S P UK VENTILATION SYSTEMS LTD S P HOUSE WENTWORTH ROAD RANSOMES EUROPARK IPSWICH SUFFOLK TEL 01473 276890 WWW SOLERPALAU CO UK REF REV 3 ...