background image

Company Name: 

Sandisk Corporation 

Eut: 

SanDisk SSD UATA 5000 1.8” 

Client Reference Number: 

QRTL06-334 

Work Order Number: 

2006137 

 

Compliance Report 

 

Page 9 of 17 

3 PRODUCT 

LABELING 

3.1 C-T

ICK 

M

ARK

 

The compliance label indicates that the product complies with the applicable standard and 
establishes a traceable link between the equipment and the manufacturer, importer or their 
agent responsible for compliance and for placing it on the Australian market. 

 

The requirements for labelling for specified electrical or electronic items are:

 

  

The mark 

to be used exactly as shown in the 

Radiocommunications (Compliance 

Labelling - Incidentals Emissions) Notice

. No variations are permitted. 

Location 

the mark and supplier identification should be a permanent feature placed 
on the external surface of the product as near as practical to the model 
identification. Where this is not practical, due to the size or nature of the 
product, the label may be placed on the labelling, packaging, warranty or 
instructions of the product. 

Method of 
marking 

the label shall be durably applied by any suitable means such as printing, 
painting, moulding, etching or engraving. 

Scale 

the mark shall be legible and visible to the unaided eye no smaller than 
3mm in diameter, with supplier identification characters no less than 1mm 
in height. 

Colour 

the label may be reproduced in any colour provided that visibility is assured 
through either contrast with the background colour or marking in relief 
(moulding, engraving etc). 

 

 

 

Note

   The C-Tick mark is a protected symbol for section 188A of the 

Radiocommunications Act 1992

 

 

Summary of Contents for SSD UATA 5000 1.8"

Page 1: ...ORT SanDisk Corporation 7 Atir Yeda Street Kfar Saba Israel 972 9 7644908 Contact Eitan Chalfon SanDisk SSD UATA 5000 1 8 February 7 2007 Report Prepared By EMC Lab Coordinator Jon Wilson Rhein Tech L...

Page 2: ...TEL listing number A97 TH 0107 states that the customer equipment referred to in the above mentioned Test Report complies in all respects with the appropriate requirements of standards listed above Th...

Page 3: ...t of the same type as that for which the permit verification of permit was issued I We agree to allow ACA access to and removal of the Compliance Folder for ongoing compliance audit purposes in accord...

Page 4: ...AILS 7 2 4 CONFIGURATION PHOTOGRAPH OF SYSTEM UNDER TEST 8 2 5 EUT EXERCISE DESCRIPTION 8 2 6 SPECIAL ACCESSORIES 8 3 PRODUCT LABELING 9 3 1 C TICK MARK 9 3 2 LABEL LOCATION 10 4 MEASUREMENT PHOTOGRAP...

Page 5: ...ta have been placed on file with the Federal Communications Commission FCC and the National Voluntary Laboratory Association Program NVLAP The power line conducted emission measurements were performed...

Page 6: ...nector Interface to host o Standards ATA 2 ATA 3 ATA 4 ATA 5 ATA 6 ATA 7 High performance o Host transfer rate 100MB s o Internal transfer read rate 62MB s o Internal transfer write rate 36MB s o Aver...

Page 7: ...0 01 08 2007 Auxiliary Equipment Part Manufacturer Model Serial Number FCC ID Cable Description RTL Bar Code Equipment Arrival Date Laptop PC Dell Latitude D420PP09S CND3520M69 DoC Unshielded Power 01...

Page 8: ...under test using a software application provided by Dell The SanDisk SSD UATA 5000 1 8 was tested as a representative of the full line of available capacities The only difference among the different s...

Page 9: ...rk and supplier identification should be a permanent feature placed on the external surface of the product as near as practical to the model identification Where this is not practical due to the size...

Page 10: ...Sandisk Corporation Eut SanDisk SSD UATA 5000 1 8 Client Reference Number QRTL06 334 Work Order Number 2006137 Compliance Report Page 10 of 17 3 2 LABEL LOCATION Label Location Bottom of SanDisk SSD U...

Page 11: ...me Sandisk Corporation Eut SanDisk SSD UATA 5000 1 8 Client Reference Number QRTL06 334 Work Order Number 2006137 Compliance Report Page 11 of 17 4 MEASUREMENT PHOTOGRAPHS 4 1 CONDUCTED MEASUREMENT PH...

Page 12: ...Company Name Sandisk Corporation Eut SanDisk SSD UATA 5000 1 8 Client Reference Number QRTL06 334 Work Order Number 2006137 Compliance Report Page 12 of 17 4 2 RADIATED MEASUREMENT PHOTOGRAPHS...

Page 13: ...4 0 56 0 22 0 46 0 12 0 Pass 3 950 Pk 34 2 1 1 35 3 56 0 20 7 46 0 10 7 Pass 17 670 Pk 25 1 2 5 27 6 60 0 32 4 50 0 22 4 Pass Phase Conductor Temperature 74 F Humidity 40 Emission Frequency MHz T e s...

Page 14: ...B m Emission Level dBuV m Limit dBuV m Margin dB Pass Fail 141 950 Qp V 355 1 5 29 8 15 6 14 2 30 0 15 8 Pass 166 200 Qp V 220 1 0 36 8 16 0 20 8 30 0 9 2 Pass 167 988 Qp V 300 1 4 39 1 16 1 23 0 30 0...

Page 15: ...r The Site Correction Factor SCF used in the above equation is determined empirically and is expressed in the following equation SCF dB m PG dB AF dB m CL dB SCF Site Correction Factor PG Pre amplifie...

Page 16: ...national LS16 110VAC 16010020082 901084 1 23 2007 16A LISN AFJ International LS16 110VAC 16010020080 901083 3 29 2007 Current Probe Telecom conducted Fischer Custom Communications F 33 1 3003 900894 3...

Page 17: ...ed in this report 9 2 RADIATED EMISSIONS MEASUREMENTS Before final measurements of radiated emissions were made on the open field three ten meter range the EUT was scanned indoor at one and three mete...

Page 18: ...Company Name Sandisk Corporation Eut SanDisk SSD UATA 5000 1 8 Client Reference Number QRTL06 334 Work Order Number 2006137 Compliance Report Page 18 of 17...

Reviews: