background image

Company Name: 

Sandisk Corporation 

Eut: 

SanDisk SSD UATA 5000 1.8” 

Client Reference Number: 

QRTL06-334 

Work Order Number: 

2006137 

 

Compliance Report 

 

Page 5 of 17 

1  GENERAL INFORMATION/TEST FACILITY AND METHODOLOGY 

The following Class B Application for ACA Compliance is prepared on behalf of

  SanDisk 

Corporation, Inc..

 in accordance with AS/NZS CISPR22:2002.  The Equipment Under Test 

(EUT) was the 

SanDisk SSD UATA 5000 1.8”.

  The test results reported in this document 

relate only to the item that was tested. 
 
All measurements contained in this Application were conducted in accordance with AS/NZS 
CISPR22:2002.  The instrumentation utilized for the measurements conforms with the CISPR 
22 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods.  
Some accessories are used to increase sensitivity and prevent overloading of the measuring 
instrument.  These are explained in the appendix of this report.  Calibration checks are 
performed regularly on the instruments, and all accessories including the high pass filter, 
preamplifier and cables. 
 
All radiated and conducted emissions measurements were performed manually at Rhein Tech 
Laboratories, Inc.  The radiated emissions measurements required by the rules were performed 
on the ten meter, open field, test range maintained by Rhein Tech Laboratories, Inc., 360 
Herndon Parkway, Suite 1400, Herndon, Va., 20170.  Complete description and site attenuation 
measurement data have been placed on file with the Federal Communications Commission 
(FCC) and the National Voluntary Laboratory Association Program (NVLAP).  The power line 
conducted emission measurements were performed in a shielded enclosure also located at the 
Herndon, Virginia facility. 

1.1 D

EVIATIONS

 

There were no deviations from the test standard(s) and/or methods.

 

1.2 

A

CCREDITATION 

S

TATEMENTS

 

 

NVLAP (USA): Accreditation under NVLAP Lab Code:  200061-0 

 

US CAB: Recognition as of U.S. Conformity Assessment Body (CAB) for EMC testing under US-EU and US-
APEC MRA; IC accepted CAB under Phase I of APEC Telecommunication MRA.  Identification  number 
US0079.  

 

FCC (USA): Listing of test sites, Registration # 90902 

 

IC (Canada): Listing of test sites, IC 2956-1 and IC 2956-2 

 

US TCB (ATCB): Certification of cooperation, granted in 2005 

 

CE Notified Body: Rhein Tech Laboratories, Inc. has been approved by TNO Certification B.V. to provide EMC 
Test Reports and Technical Construction Files to TNO Certification B.V.  Rheintech Certification number:  
10118957 

 

AUSTEL (Australia): Acceptance as of a Listed Test House, A97/TH/0107 

 

ANATEL (Brazil, telecommunication): NCC certification for performing tests 

 

Ministry of Commerce (New Zealand): Approval of a test laboratory: ECR 3-9 BAE 

 

VCCI (Japan): Approval and registration of RTL test sites as R-1113 and C-1172 

 

BSMI Rhein Tech Labs has been validated by the Chinese Taipei Bureau of Standards, Metrology, and 
Inspection (BSMI) under the Asia Pacific Economic Cooperation Mutual Recognition Arrangement (APEC 
MRA).  BSMI number: SL2-IN-E-055R. 

 

RTL’s testing sites are recognized by the VCCI and registered under Numbers R-1113 and C-1172 

 

 

Summary of Contents for SSD UATA 5000 1.8"

Page 1: ...ORT SanDisk Corporation 7 Atir Yeda Street Kfar Saba Israel 972 9 7644908 Contact Eitan Chalfon SanDisk SSD UATA 5000 1 8 February 7 2007 Report Prepared By EMC Lab Coordinator Jon Wilson Rhein Tech L...

Page 2: ...TEL listing number A97 TH 0107 states that the customer equipment referred to in the above mentioned Test Report complies in all respects with the appropriate requirements of standards listed above Th...

Page 3: ...t of the same type as that for which the permit verification of permit was issued I We agree to allow ACA access to and removal of the Compliance Folder for ongoing compliance audit purposes in accord...

Page 4: ...AILS 7 2 4 CONFIGURATION PHOTOGRAPH OF SYSTEM UNDER TEST 8 2 5 EUT EXERCISE DESCRIPTION 8 2 6 SPECIAL ACCESSORIES 8 3 PRODUCT LABELING 9 3 1 C TICK MARK 9 3 2 LABEL LOCATION 10 4 MEASUREMENT PHOTOGRAP...

Page 5: ...ta have been placed on file with the Federal Communications Commission FCC and the National Voluntary Laboratory Association Program NVLAP The power line conducted emission measurements were performed...

Page 6: ...nector Interface to host o Standards ATA 2 ATA 3 ATA 4 ATA 5 ATA 6 ATA 7 High performance o Host transfer rate 100MB s o Internal transfer read rate 62MB s o Internal transfer write rate 36MB s o Aver...

Page 7: ...0 01 08 2007 Auxiliary Equipment Part Manufacturer Model Serial Number FCC ID Cable Description RTL Bar Code Equipment Arrival Date Laptop PC Dell Latitude D420PP09S CND3520M69 DoC Unshielded Power 01...

Page 8: ...under test using a software application provided by Dell The SanDisk SSD UATA 5000 1 8 was tested as a representative of the full line of available capacities The only difference among the different s...

Page 9: ...rk and supplier identification should be a permanent feature placed on the external surface of the product as near as practical to the model identification Where this is not practical due to the size...

Page 10: ...Sandisk Corporation Eut SanDisk SSD UATA 5000 1 8 Client Reference Number QRTL06 334 Work Order Number 2006137 Compliance Report Page 10 of 17 3 2 LABEL LOCATION Label Location Bottom of SanDisk SSD U...

Page 11: ...me Sandisk Corporation Eut SanDisk SSD UATA 5000 1 8 Client Reference Number QRTL06 334 Work Order Number 2006137 Compliance Report Page 11 of 17 4 MEASUREMENT PHOTOGRAPHS 4 1 CONDUCTED MEASUREMENT PH...

Page 12: ...Company Name Sandisk Corporation Eut SanDisk SSD UATA 5000 1 8 Client Reference Number QRTL06 334 Work Order Number 2006137 Compliance Report Page 12 of 17 4 2 RADIATED MEASUREMENT PHOTOGRAPHS...

Page 13: ...4 0 56 0 22 0 46 0 12 0 Pass 3 950 Pk 34 2 1 1 35 3 56 0 20 7 46 0 10 7 Pass 17 670 Pk 25 1 2 5 27 6 60 0 32 4 50 0 22 4 Pass Phase Conductor Temperature 74 F Humidity 40 Emission Frequency MHz T e s...

Page 14: ...B m Emission Level dBuV m Limit dBuV m Margin dB Pass Fail 141 950 Qp V 355 1 5 29 8 15 6 14 2 30 0 15 8 Pass 166 200 Qp V 220 1 0 36 8 16 0 20 8 30 0 9 2 Pass 167 988 Qp V 300 1 4 39 1 16 1 23 0 30 0...

Page 15: ...r The Site Correction Factor SCF used in the above equation is determined empirically and is expressed in the following equation SCF dB m PG dB AF dB m CL dB SCF Site Correction Factor PG Pre amplifie...

Page 16: ...national LS16 110VAC 16010020082 901084 1 23 2007 16A LISN AFJ International LS16 110VAC 16010020080 901083 3 29 2007 Current Probe Telecom conducted Fischer Custom Communications F 33 1 3003 900894 3...

Page 17: ...ed in this report 9 2 RADIATED EMISSIONS MEASUREMENTS Before final measurements of radiated emissions were made on the open field three ten meter range the EUT was scanned indoor at one and three mete...

Page 18: ...Company Name Sandisk Corporation Eut SanDisk SSD UATA 5000 1 8 Client Reference Number QRTL06 334 Work Order Number 2006137 Compliance Report Page 18 of 17...

Reviews: