Set up Low Power reminder
The user can set the SMS/COTA command to alert user if the battery voltage is low or automatically shut down
system when the battery voltage reaches a certain threshold.
Setup Format: #<User Name>, <Password>,<Function Code>, <Voltage Value 1>,< Voltage Value 2>*
Command: #UserName,0000,LP,3650,50*
Table: Low Power Setup Description
Table: Low Power Setup Response Description
SMS/ COTA Command Description
#
Start sign.
UserName
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
Function Code
Code “LP” defines the Low Power alarm setting.
Voltage Value 1 (V1)
The range is 3500~3800, when the voltage reaches this value, the “LP” event will
be sent out
Voltage Value 2 (V2)
The range is 1~99, when the voltage is lower than V1 - V2, “LP2” event will be sent
out and shut down
*
End sign.
Situation
Message Reply
Setup Succeed
[username] + setup OK. Device low power value setting is updated.
Setup fail
[username] + Setup fail. Device low power value setting is not change.