Samwontech TEMI 880 Instruction Manual Download Page 1

TEMI880

INSTRUCTION MANUAL

Temperature

Pressure Programmable Controller

Summary of Contents for TEMI 880

Page 1: ...TEMI880 INSTRUCTION MANUAL Temperature Pressure Programmable Controller...

Page 2: ......

Page 3: ...rd 10 4 2 Alphabet keyboard 11 5 Block Diagram of the Basic Processing 12 6 Main Screen 13 7 Operation Screen 14 7 1 Stop Screen 14 7 2 Confirmation Window 16 7 3 Run Screen 17 7 4 Test Status 18 8 Fu...

Page 4: ...ther Set 35 10 Assistant Screen 36 11 Program Set Screen 38 11 1 Edit Segment 39 11 1 1 Insert Method of Segment 40 11 1 2 TS Set 41 11 1 3 TS Operation within Segment 42 11 2 Loop Set 43 11 2 1 Segme...

Page 5: ...and fully understand how to operate this product before operation 3 This manual is intended to describe the functions and the operate way of this product 4 Redistribution use this manual with or witho...

Page 6: ...TEMI 880 4...

Page 7: ...ded actual expenses after warranty period 3 This warranty does not cover damage due to loss password accident fire flood and or other acts of God misuse instability improper installation improper or u...

Page 8: ...ature before plugging it in and warm it up for 30 minutes after plugging it in Otherwise it may not function normally and the product may be damaged 5 Do not use around any machine which heat up Avoid...

Page 9: ...nce dimension 184 144 107 7 mm L H W 2 Mounting dimension 173 133 mm L H CAUTION Before install wiring be sure to turn off the system or else you will get an electrical shock Do not tighten the mounti...

Page 10: ...EMI 880 8 3 Installation 3 1 Body Terminal TEMI880 Body Terminal Figure 3 3 2 Applicable Tightening terminal Please use tightening terminal with insulating sleeve for M3 5 screws as following Figure 4...

Page 11: ...TEMI 880 9 3 3 I O Relay Board I O Relay Board Terminal Figure 5...

Page 12: ...1 Digital keyboard Digital Keyboard Figure 6 Figure 7 1 Data range valid data range 2 decimal point 3 input sign 4 OK save input data and close the keyboard 5 Esc cancel input setting value 6 OFF clic...

Page 13: ...cape character ABC Chinese Symbol and so on 2 Space space button 3 Next line jump to next line 4 delete all input data 5 back to last step 6 save input data and go back to last step 7 page up or down...

Page 14: ...15 seconds to enter Monitor Screen click on the MAIN pattern can enter Main Screen as Figure 11 CAUTION When connection do not mix up the input polarity Connection with the wrong polarity can cause t...

Page 15: ...CR button to enter the Operation Screen See 7 Operation Screen 2 Func Set click on the FUNC SET button to enter the Function Set Screen See 8 Function Set Screen 3 Graph click on the GRAPH button to e...

Page 16: ...on Screen 7 1 Stop Screen Fix Mode Stop Screen Figure 11 Program Mode Stop Screen Figure 12 1 HOME button click on it can back to Main Screen 2 SV In Fix mode display setting value and click it can se...

Page 17: ...when TPV Pre H SV PRE AL will effect User click on this button to close alarm and Press will start run 10 display the test status click on this button shift to Test Status click it again for back See...

Page 18: ...status 4 AT enable or disable the Temp Press auto tuning under current setting point status Turn ON AT function See 10 Assistant Screen 5 Jump stop the current running segment and jump to next segmen...

Page 19: ...display total running time and current running program NO 001 segment NO 001 3 Deflate turn ON or OFF Deflate function Seting its action mode See 10 Assistant Screen 4 The press status display display...

Page 20: ...rn red 3 Remain in Fix mode display the remaining time of total set time in Program mode display the remaining time of current running segment s set time 4 Set time in Fix mode display total setting t...

Page 21: ...detail See 8 2 Fix Set 3 Prog set setting the PROG MODE detail click on it enter Program Set Screen See 11 Program Set Screen 4 Waiting set setting the standby function See 8 3 Waiting Set 5 Time res...

Page 22: ...FIX mode test another way to set the Run Time of FIX Mode See 8 2 FIX Set Prog NO selecting the run program NO of Program Mode 3 Boot mode selecting the restore status after power off during test Sto...

Page 23: ...x Set screen Fix Set Screen Figure 23 1 Run time See 8 1 Mode Set 2 Temp Press slope setting FIX Mode temp press slope And their PV goes to SP gradually both up and down according to the slope setting...

Page 24: ...TEMI 880 22 8 2 1 Slope Operation A case where temperature SP TSP is changed SP value is changed gradually from PV to TSP Slope Operation Figure 24...

Page 25: ...ng function 2 Wait time setting the waiting time 3 Temp wait zone setting the temperature range to start the waiting function 4 Press wait zone setting the Pressure range to start the standby function...

Page 26: ...TEMI 880 24 8 3 1 Wait Function Operation The relation of the wait operation and wait time please read Figure 26 Wait Function Operation Figure 26...

Page 27: ...ter Time Reserve screen as Figure 27 Time Reserve Screen Figure 27 1 Cur time adjustment current time 2 Reserve start turn on or off the reserve function Turn on this function will pop up time set win...

Page 28: ...et function in Figure 28 will pop up Time Set Window as Figure 29 Click on CUR TIME button can adjust time as same as controller current time Step 2 setting the target reserve time and click on OK but...

Page 29: ...mal selecting turn on or turn off the Normal Set function If turn on this function the controller will control the test box back to Normal SV after finished the test 2 Normal SV setting the normal tem...

Page 30: ...lect the lowest display point of Curve Show screen See 9 1 Highest Lowest Display Point 3 Time display display the recorded time of current curve 4 Curve select click on any point in the Curve to sele...

Page 31: ...Show screen of curve in Figure 34 Curve Select Figure 37 1 Click on any point in the Curve Show screen will pup to the Black Line and Curve Select in right side Users can press and move the Black link...

Page 32: ...G PATTERN in Figure 34 to enter Time Scale Display Select screen as Figure 38 Time Scale Display Select Screen Figure 38 Change time scale 0M 1M 2M 3M 4M 0M 2M 4M 6M 8M 0M 5M 10M 15M 20M 0M 10M 20M 30...

Page 33: ...n review its curve and table or delete it See 9 4 1 Historical File Manage 2 Ellipsis pattern click on it to manage the order of historical files See 9 4 3 Historical Files Order CAUTION File List wil...

Page 34: ...eview this historical file s corresponding curve 2 Table click on it to review this historical file s corresponding table See 9 4 2 Table Show 3 Del delete the historical file which you had selected 4...

Page 35: ...42 2 Head click on this button jump to the first page of table 3 Tail click on this button jump to the last page of table 4 10 click on this button jump backwards based on the 10 pages unit 5 10 clic...

Page 36: ...he display order of historical files is order by the record time clockwise 2 Reverse click on it to setting the display order of historical files is order by the record time anti clockwise 3 Jump clic...

Page 37: ...AR PATTERN pattern in Figure 34 to enter Curve Set screen as Figure 44 Other Screen Figure 44 1 Record interval setting the curve record interval of test 2 Disk used display the controller used storag...

Page 38: ...off set time of controller backlight 2 Brightness adjustment the LCD Brightness function 3 Lock password setting a password for keyboard lock function initial is 0 0 means PSD isn t word click in tit...

Page 39: ...ction See 7 2 Confirmation Window 6 Beep selecting turn ON or OFF the beep function 7 Deflate ON time setting wait time for deflate time signal output 8 Deflate OFF time setting run time for deflate t...

Page 40: ...to add up a new program 3 SEG NUM setting each program s segment value See 11 1 Segment Edit 4 Cycle setting the program or segment cycle See 11 2 Loop Set 5 Other other set of program See 11 3 Other...

Page 41: ...late curve 3 TS setting the time signal operation See 11 1 2 TS Set 4 Time setting the running time of this segment 5 Press setting the pressure value of this segment 6 Temp setting the temperature va...

Page 42: ...Segment Figure 49 Figure 50 1 Step 1 selecting 002 segment click on its number and its color change red 2 Step 2 will pop up Select Window as Figure 49 click on the INSERT button 3 Step 3 a new segme...

Page 43: ...51 1 NO totally 8 actions OFF means always OFF ON means always ON AC1 AT6 need to set its value by user 2 Delay setting delay time to delay turn on the time signal action 3 ON time setting wait time f...

Page 44: ...TEMI 880 42 11 1 3 TS Operation within Segment The Time Signal operation within segment please read Figure 52 TS Operation Figure 52...

Page 45: ...in the same Program Start setting the segment cycle s beginning segment number End setting the segment cycle s ending segment number Count setting the segment cycle counts See 11 2 1 Segment Repeat E...

Page 46: ...01 02 03 04 2 02 03 04 3 03 04 05 4 03 04 05 06 07 08 2 1 01 02 03 04 05 2 03 04 05 3 02 03 04 4 02 03 04 05 06 07 08 3 1 01 02 03 2 02 03 3 05 06 4 05 06 07 08 4 1 01 02 03 04 05 06 2 05 06 3 02 03...

Page 47: ...repeat please reading the table as following Program Repeat Process E g Set Value Repeat Process 1 Subject Program 1 RPT Program 1 Program 2 2 Subject Program 2 RPT Program 2 Program 2 Program 3 3 Su...

Page 48: ...and click on COPY button input target NO is program 3 The program s name do not change but its setting value is as same as program 1 3 Start this prog start the program you had select 4 Del this prog...