CONTROL UNIT FOR TWO-LEAF GATES
INSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE
GE UNIR DL
GE UNI R DL
GE UNI RS DL
Page 1: ...CONTROL UNIT FOR TWO LEAF GATES INSTRUCTIONS AND WARNINGS FOR INSTALLATION USE AND MAINTENANCE GE UNIR DL GE UNI R DL GE UNI RS DL ...
Page 2: ... r t s I u r e v v a e i n o i z s n i l r e p e z n e t l e n o i z a l l a t e o s u m a l n a u e n o i z n e t 8 8 8 STANDARD INSTALLATION Tab 1 Components and devices of a typical GE UNI R DL automation Tab 2 Description of the content of a GE UNI R DL control unit pack ...
Page 3: ...0 5 2 m m 4 8 1 m m 0 4 m c n i m 5 3 4 1 2 GEBOX ASSEMBLY INSTRUCTIONS ...
Page 4: ...2 are normally lit for the NO inputs open close and step the corresponding LEDS L8 L9 and L10 are normally off These LEDs therefore indicate any malfunction of the connected devices ATTENTION the cables used must be suited to the type of installation It is the Fitter s responsibility to choose appropriate material Pos Type of cable Connection Electricity supply line Internal button panel Sensitive...
Page 5: ...age during both opening and closure Motion resumesduring opening when the photocell or safety device is disengaged Leave jumpered if no device is envisaged 6 12 PHOTO NC input for photocells or safety devices Does not intervene during gate opening during closure causes reversal of gate motionuntil open Leave jumpered if no device is envisaged 16 13 ELECTROLOCK 12 V ac output for connection of the ...
Page 6: ...l board to aid programming PROGRAMMING RADIO TRANSMITTERS TOTAL OPENING COMMAND Press the radio icon button top left once The left green led will light and the first L to R of the top 5 led s A will light Hold down the button on the transmitter that you want to perform a total opening of the gates Once the top 5 led s light the transmit ter has been coded To exit wait 25 seconds or push the radio i...
Page 7: ...he radio icon button top left for 5 seconds The left green led will light and seconds The left green led will light and start flashing start flashing Hold down the button on the transmitter you Hold down the button on the transmitter you wish to delete until all the top 5 led s light wish to delete until all the top 5 led s light The transmitter has been deleted The transmitter has been deleted To...
Page 8: ...ning phase When gate has been opened after passing between the photocells the gates will close OPTION MENU 1 OPTION MENU 1 Press the option button bottom right once then press in sequence to scroll through the options as shown by the five Press the option button bottom right once then press in sequence to scroll through the options as shown by the five led s at the top The flashing of the led indi...
Page 9: ...of motion before stopping awaiting a command Wait 25 seconds or press again to quit 45 35 45 35 Press MINIMUM MAXIMUM LEDS ON OBSTACLE DETECTION H S I L G N E NO OBSTACLE DETECTION FORCE FORCE Press the force button bottom left and the OBSTACLE DETECTION OBSTACLE DETECTION The automation is fitted with an obstacle detection system The automation inverts its movement when it strikes an The automati...
Page 10: ...io transmitter or with a switch Give a command with a radio transmitter or with a switch connected across terminals 6 10 Motor 2 will run closed connected across terminals 6 10 Motor 2 will run closed and shut off when it drives against the close stop The right and shut off when it drives against the close stop The right red led will remain on red led will remain on Give a second command using the...
Page 11: ...nual must always be observed when installing connecting adjusting testing and setting the control unit The Manufacturer declines all responsibility for damage or injury caused by non observance of the instructions contained in this manual The Manufacturer declines all responsibility for damage and faults to the control unit caused by non observance of the instructions contained in this manual Keep...
Page 12: ...neral mechanical and electrical diagram risk analysis and solutions adopted for eliminating or reducing risks manuals of the individual components list of the components used instructions for use and warnings concerning use by the owner system maintenance record declaration of the system s CE conformity b Fix a CE marking plate to the gate bearing at least the following information Name and addres...
Page 13: ...person with a similar qualification in order to avoid risks Do not perform technical or programming modifications on the control unit Operations of this type may cause malfunctions and or risk of accidents The manufacturer declines all responsibility for damage caused by products that have been modified In the event of intervention of automatic or fuse switches before restoring function conditions...
Page 14: ...ised doors testing methods EN 12453 Industrial commercial and garage doors and gates Safety in the usage of motorised doors Requisites EN 60204 1 1997 Machinery safety Electric equipment of the machine Part 1 general rules EN 60950 Information technology equipment Safety Part 1 General requisites ETSI EN 301489 3 2001 Electromagnetic compatibility for radio equipment and appliances EN 300220 3 200...
Page 15: ...Address Factory 19 5 Lyn Parade PRESTONS NSW 2170 Email sales SAMT com au Telephone 02 9607 4100 www samtgatemotors com au ...