Samsung UST24P8GB Owner'S Instructions Manual Download Page 1

ENGLISH

ESP

AÑOL

FRANÇAIS

Split-type Room Air Conditioner 

(Cool)

Aire acondicionado doméstico sistema Split 

(Refrigeración)

Climatiseur de type Séparé 

(Refroidissement)

AST24P8GB
AST24P8GE

Indoor unit

UST24P8GB
UST24P8GE

Outdoor unit

OWNER’S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D’UTILISATION

E S F A DB98-12990A(1)

Summary of Contents for UST24P8GB

Page 1: ... Cool Aire acondicionado doméstico sistema Split Refrigeración Climatiseur de type Séparé Refroidissement AST24P8GB AST24P8GE Indoor unit UST24P8GB UST24P8GE Outdoor unit OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION E S F A DB98 12990A 1 ...

Page 2: ...horized service personnel DANGER Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioner Do not expose the air conditioner directly to water Do not touch the power supply plug with wet hand...

Page 3: ... 13 Selecting Energy Saving Mode 14 Generating Anion 15 Generating Oxygen 16 Adjusting the Air Flow Direction Vertically 17 Adjusting the Air Flow Direction Horizontally 17 PROGRAMMING YOUR AIR CONDITIONER Setting the On Timer 18 Setting the Off Timer 19 Setting the Sleep Timer 20 RECOMMENDATIONS FOR USE Operating Recommendations 21 Temperature and Humidity Ranges 22 Operating Your Air Conditioner...

Page 4: ...erature on the display N N N No o o ot t t te e e e Indoor Unit The design and shape are subject to change according to the model Air filter under the grille Air flow blades outlet Remote Control Sensor On Off switch Timer indicator Fan speed setting Sleep Timer indicator Oxygen indicator Operation indicator Set temperature room temperature Anion indicator Auto grille Air Inlet Room temperature se...

Page 5: ...E 5 ENGLISH Outdoor Unit Oxygen outlet equipment inside Oxygen supply hose connection port Air inlet Rear Air outlet Connection Valve ...

Page 6: ...Anion button Energy saving button Turbo button Oxygen button Timer Set Cancel button Digital i On Off button Temperature setting Air flow direction Turbo mode Sleep mode Oxygen mode On Off button Temperature adjustment buttons Swing button Fan speed adjustment button Sleep button On Timer button Off Timer button Fan speed Anion indicator On Timer setting Battery discharge indicator ...

Page 7: ...take full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 6 Indoor and outdoor units Remote control buttons and display They will help you find the buttons and understand the symbols displayed In the manual you will find a series of step by step procedures for each function available The illustrations in the step by step proce...

Page 8: ...e battery with on the remote control 1 2 Close the cover by sliding it back until it clicks into place 3 Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of batteries together Batteries may be completely discharged after 12 months even if they have not actually been used You must insert or replace the remote control batteries when You purchase the air conditioner The rem...

Page 9: ...ry press the On Off button Result The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes IMPORTANT N N N No o o...

Page 10: ...ed Possible temperatures are between 18 C and 30 C inclusive Result Each time you press the button The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts cooling provided that the room temperature is higher than the selected temperature If the room temperature reaches the set temperature the air conditioner stops cooling but the fan is still operating 3 Select the fan ...

Page 11: ... Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps 2 Press the button Result The temperature and fan settings are adjusted automatically The air conditioner cools the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previous mode temperature and fan settings But if you press the button in DRY or F...

Page 12: ... three minutes 2 If the is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in DRY mode N N N No o o ot t t te e e e You can change modes at any time 3 To adjust the temperature press the button one or more times until the required temperature...

Page 13: ...op of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in FAN mode The temperature is set automatically N N N No o o ot t t te e e e You can change modes at any time 3 Select the fan speed by pressing the button one or more times until the required setting is displayed L...

Page 14: ...ure under 26 C cancel the Energy saving mode before adjusting the temperature 6 To control the direction of the air flow refer to page 17 5 To select the fan speed press the button one or more times until the required setting is displayed E 14 1 If necessary press the On Off button Result The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lig...

Page 15: ...air conditioner generates anion The indoor unit beeps 2 If you wish to stop the Anion function press the button again Result The air conditioner is reset automatically to the previous mode temperature and fan settings 3 To control the direction of the air flow refer to page 17 N N N No o o ot t t te e e e If you press the button during off the air conditioner will turn on automatically and generat...

Page 16: ... change modes at any time The oxygen mode operates in the same way with the fan speed 3 To control the direction of the air flow refer to page 17 You can check if oxygen generates for yourself by using the following test Open the front grille 1 Block the end of the oxygen supply hose with your finger for 3 or 4 seconds and open it If you feel the flow of oxygen it naturally emits from the end of h...

Page 17: ...f the outer air flow blade on the bottom of the unit thus increasing the efficiency of the air conditioner 1 Press the button one or more times as required Result The outer blade is adjusted vertically RECOMMENDATION When Adjust the blade to face Cooling Upwards 2 If you want the blade to move up and down automatically when the air conditioner is operating press the button Result The blade move up...

Page 18: ...inclusive 1 Press the Set Cancel button to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The selected mode and the temperature on the display disappear after 10 seconds The air conditioner will switch on automatically when the counter displayed on the remote control reaches the set time and disappears the On timer setting 2 Press the Set Cancel b...

Page 19: ...to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote control reaches the set time and disappears the Off timer setting 2 If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours 1 Press the button until 2 0 Hr is displayed 2 ...

Page 20: ... the button Result The indoor unit beeps The air conditioner will be controlled as indicated in the illustrations below Cooling The desired temperature is increased by 1 C every hour When it has been increased by 2 C after two hours the temperature is maintained for four hours To Cancel the Sleep Timer If you no longer wish to use the Sleep Timer that you have set you can cancel it at any time Pre...

Page 21: ...t you should follow when using your air conditioner Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating the unit is switched off When the power returns the air conditioner starts up again automatically E 21 ENGLISH ...

Page 22: ...ity Cooling 18 C to 32 C approx 21 C to 43 C approx 80 or less Drying 18 C to 32 C approx 18 C to 43 C approx If the cooling operation is used at over 33 C indoor temperature then it does not cool at its full capacity If it s below 0 C outside the oxygen mode may not operate automatically to protect the air conditioner Low temperatures A water leak or some other malfunction may occur if the heat e...

Page 23: ...the indoor unit Result The OPERATION indicator on the indoor unit comes on The indoor unit beeps The air conditioner starts up in the most suitable mode for the room temperature Room Temperature Operating Mode Temperature Setting 21 C or above Cool 24 C approx 3 To switch the air conditioner off press the ON OFF switch again N N N No o o ot t t te e e e Even if the air conditioner has been switche...

Page 24: ...erature may be too low Dust may be blocking the air filter guard refer to page 26 for cleaning instructions Check that there is no obstacle in front of the outdoor unit Check that the operating mode is set to COOL or FAN in the AUTO mode the fan speed changes automatically and in the DRY mode it is set to AUTO Check that the air conditioner has been switched on if necessary press the On Off button...

Page 25: ...iling when you use the function of generating oxygen Check that the difference of temperature is big The difference of temperature may cause the water drops Wait for a minute after selecting the oxygen function Check that you install the hose right and operate it again Or consult the authorized service center Problem It sounds strange Water drops from the connection part of an outdoor unit It does...

Page 26: ...nt grille up slightly then open the grille by pulling right and left sides of the grille 1 Slide the lower front grille down 4 Lift out the bottom edge of the air filters and pull down to release them 5 Remove all dust on the air filters with a vacuum cleaner or brush 6 When you have finished insert the top part of the filters into their slot and push down on the bottom edge until they click into ...

Page 27: ...Technical Specifications E 27 ENGLISH Model Indoor unit AST24P8GB AST24P8GE 220V 60Hz 220 240V 50Hz Power Supply ...

Page 28: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR Printed in Korea ...

Reviews: