Samsung UQ07S2GE Service Manual Download Page 1

INDOOR UNIT

SH07ZS2
SH07ZS2A
SH09ZS2
SH09ZS2A
SH12ZS4
SH12ZS4A
AQ07S2GE
AQ09S2GE
AQ12S4GE
AQT12S4GB
AQT12S4GE

OUTDOOR UNIT

SH07ZS2X
SH07ZS2AX
SH09ZS2X
SH09ZS2AX
SH12ZS4X
SH12ZS4AX
UQ07S2GE
UQ09S2GE
UQ12S4GE
UQT12S4GB
UQT12S4GE

SERVICE

Manual

CONTENTS

AIR CONDITIONER

1. Product Specifications

2. Operating Instructions

3. Disassembly and Reassembly

4. Refrigerating Cycle Diagram

5. Set Up the Model Option

6. Troubleshooting

7. Exploded Views and Parts List

8. Block Diagram

9. PCB Diagram

10. Wiring Diagram

11. Schematic Diagram

ROOM AIR CONDITIONER

 DB98_16693A(2)_co  3/19/04 2:26 PM  Page 3

Summary of Contents for UQ07S2GE

Page 1: ...SH12ZS4AX UQ07S2GE UQ09S2GE UQ12S4GE UQT12S4GB UQT12S4GE SERVICE Manual CONTENTS AIR CONDITIONER 1 Product Specifications 2 Operating Instructions 3 Disassembly and Reassembly 4 Refrigerating Cycle Diagram 5 Set Up the Model Option 6 Troubleshooting 7 Exploded Views and Parts List 8 Block Diagram 9 PCB Diagram 10 Wiring Diagram 11 Schematic Diagram ROOM AIR CONDITIONER ...

Page 2: ...00 BTU h 1 4 6 2 22 36 50 3 24 3 65 1 220 240 50 680 630 3 0 2 8 98 6 97 8 21 0 250V 10 16A 795x258x179 660x495x235 31 3x10 2x7 0 26 0x19 5x9 3 7 5 26 0 ø6 35 x 5 ø9 52 x 5 ø18 x 2 000 Rotary Cross flow Propeller steel steel 11 25 2ROW 10STEP 1ROW 18STEP CAPILLARY TUBE 290 680 MRA99137 9201 Size Power Perfor mance Wall mounted 2 60kW 8 990 BTU h 2 90kW 8 990 BTU h 1 4 6 8 22 39 51 2 89 3 41 1 220 ...

Page 3: ... 24 36 50 3 15 3 53 1 220 240 50 730 680 3 3 3 1 96 2 95 4 21 0 250V 10 16A 795x258x179 660x495x235 31 3x10 2x7 0 26 0x19 5x9 3 7 5 26 1 ø6 35 x 5 ø9 52 x 5 ø18 x 2 000 Rotary Cross Flow Propeller steel steel 11 25 2ROW 10STEP 1ROW 18STEP CAPILLARY TUBE 360 630 RBC12144 12500 Size Power Perfor mance Wall mounted 2 65kW 8 990BTU h 2 90kW 8 990BTU h 1 4 7 0 24 39 51 2 82 3 30 1 220 240 50 940 880 4 ...

Page 4: ...3 15 3 53 1 220 240 50 730 680 3 3 3 1 96 2 95 4 21 0 250V 10 16A 795x258x179 660x495x235 31 3x10 2x7 0 26 0x19 5x9 3 7 5 26 1 ø6 35 x 5 ø9 52 x 5 ø18 x 2 000 Rotary Cross flow Propeller steel steel 11 25 2ROW 10STEP 1ROW 18STEP CAPILLARY TUBE 360 630 RBC12144 12500 Size Power Perfor mance Wall mounted 9 000 BTU h 10 000 BTU h 1 4 7 0 24 39 51 2 82 3 30 1 220 240 50 940 880 4 3 4 0 95 0 95 7 21 0 ...

Page 5: ...n Device OLP Cooling Test Condition Maximum Operation Condition Indoor unit Outdoor unit Indoor unit Outdoor unit Wall mounted 12 000 13 000 10 500 1 9 8 2 2 4 43 53 10 0 10 5 7 44 1 220 60 1 200 1 240 1 410 5 5 5 7 6 5 99 2 98 9 98 6 32 0 250V 10 16A 890x285x179 720x530x260 35 0x11 2x7 0 28 3x20 9x10 2 8 5 33 0 ø6 35 x 5 ø12 7 x 5 ø18 x 2 000 Rotary Cross Flow Propeller steel steel 15 25 2ROW 12S...

Page 6: ...ndoor inlet air D B temp C 20 25 30 35 40 45 32 4 24 0 30 6 22 5 28 8 21 0 27 0 19 0 24 0 17 0 21 5 15 0 6 5 5 5 4 5 3 5 9K BTU Outdoor inlet air D B temp C Low pressure kg cm 2 G Indoor inlet air D B temp C 20 25 30 35 40 45 32 4 24 0 30 6 22 5 28 8 21 0 27 0 19 0 24 0 17 0 21 5 15 0 6 5 5 5 4 5 3 5 12K BTU Outdoor inlet air D B temp C Low pressure kg cm 2 G Indoor inlet air D B temp C ...

Page 7: ... run the air conditioner or On Off timer set up Turbo Sleep mode selection button Press the button one or more times until appears The air conditioner cools or heats the room as quickly as possible After 30minutes the air conditioner is reset automatically to the previous mode UP Swing button It adjusts the airflow to upward and downward Mode selection button Each time you press this button Mode i...

Page 8: ... temperature release Prevention against freeze 5 TURBO MODE This mode is available in AUTO COOL HEAT DRY FAN MODE When this button is pressed at first the air conditioner is operated powerful state for 30 minutes regardless of the set temperature room temperature When this button is pressed again or when the operating time is 30 minutes turbo operation mode is canceled and returned to the previous...

Page 9: ...rs OFF TIMER The Off Timer enables you to switch off the air conditioner automatically after a given period of time You can set the period of time from 30 minutes to 24 hours 11 SELF DIAGNOSIS 12 BUZZER SOUND Whenever the On Off button is pressed or whenever change occurs to the condition which is set up or select the compulsory operation mode buzzer is sounded beep Lamp flickering Lamp off Indoor...

Page 10: ...Replace PCB Model option 2 2 1 Replace PCB model option No Yes Remove power cord Replace the PCB module Check the connection and plug in Refer to set up the Model option 16 18page Replace another PCB Does all display lamp blink ...

Page 11: ...ide the lower Front Grille down then disassemble it by pulling it forwards 5 Take the left and right Filter out 6 Loosen one of the right screw and separate the Terminal Cover 7 Detach the thermistor from the Front Grille 8 Loosen 5 fixing screws of Front Grille 9 At first press the left and center hook of the back side of the Panel Grille with the thumb to remove the hook And press the right of t...

Page 12: ...uding Power Cord 2 Detach the outdoor unit connection wire from the Terminal Block 3 If pulling the main PCB up it will be taken out 1 Pull Tray Drain out from the Back Body 1 Loosen 2 fixing earth screws of right side 2 Detach the Connection Pipe 3 Detach the Holder Pipe at the rear side 4 Loosen 3 fixing screws of right and left side 5 Detach the Heat Exchanger from the indoor unit ...

Page 13: ...eassembly No Parts Procedure Remark 5 Fan Motor Cross Fan 1 Loosen 2 fixing screws and detach the Motor Holder 2 Loosen 1 screw of Fan Motor By use of M3 wrench 3 Detach the Fan Motor from the Fan 4 Detach the Fan from the left Holder Bearing ...

Page 14: ...xing screw and detach the Cover Terminal 2 Loosen 1 fixing screw and detach the Cover Control 3 Detach the connection wire from the Terminal Block 4 Loosen 13 fixing screws and detach the Cabinet Front 5 Loosen 1 fixing screw of Ass y E part 6 Loosen 4 fixing screws and detach the Cabinet Side ...

Page 15: ...detach the Motor 4 Loosen 5 fixing screws and detach the Motor Bracket from the Base 1 Loosen 2 fixing screws of left and right side 2 Disassemble the inlet and outlet pipe by welding 3 Detach the Heat Exchanger 1 Open the Terminal Cover of Compressor and unscrew the Connection Terminal 2 Disassemble the inlet and outlet pipe of Compressor by welding 3 Loosen 3 bolts of the lower part 4 Detach the...

Page 16: ...rigerating Cycle Diagram Indoor Unit Outdoor Unit T1 T2 2 Way valve 3 Way valve Gas side Heat Exchanger Heat Exchanger Liquid side Capillary tube 4 Way valve Cooling Heating Gas leak check point Compressor Cross fan Propeller fan ...

Page 17: ...sh the button the display panel reads or repeatedly Push the button to set the display panel to Every time you push the button the display panel reads repeatedly Setting is not required if you must a value which has a default 3 Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 4 Push the button to set the display panel to Every time you p...

Page 18: ...on key to set the display part to and check the display part The display part shows Press the Mode Selection key to set the display part to and check the display part The display part shows Step 4 Pressing the ON OFF button When pressing the operation ON OFF key with the direction of remote controller for unit the sound Ding or Diriring is heard and the OPERATION ICON lamp of the display is flicke...

Page 19: ... SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SH07ZS2 SH07ZS2A AQ07S2GE SH09ZS2 SH09ZS2A AQ09S2GE SH12ZS4 SH12ZS4A AQ12S4GE AQT12S4GB AQT12S4GE 0 2 4 5 6 7 1 7 A 2 0 c 0 2 5 2 6 6 1 7 A 2 3 F 0 2 5 3 6 5 1 7 A 2 3 F 0 6 6 0 6 5 1 7 A 3 5 1 0 6 7 0 6 6 1 7 A 3 5 1 0 6 7 0 E 6 1 7 A 3 5 1 ...

Page 20: ... The compressor and indoor fan stop intermittently in HEAT mode In case of heat pump model Indoor fan and outdoor fan stop operation intermittently in a HEAT mode 1 2 3 4 5 6 7 8 9 Operation of air conditioner Explanation It indicates power is on The LED stops blinking if the opera tion ON OFF button on the remote control unit is pushed In happens after a delay of 3 minutes when the compressor is ...

Page 21: ...ER TURBO Lamp flickering Lamp off No response from the remote control operation signal Unable to operate the outdoor unit Plug out and plug in 5 seconds later Press the TURBO button with the remote control In 3 minutes check the voltage between the indoor unit terminal block N 1 and 1 Able to operate the remote control Unable to operate the remote control AC198V AC242V No power source displayed OK...

Page 22: ...he air conditioner Check whether two wires of power cord are connected correctly to the terminal block and control board Check whether the fuse on the control board is normal FUSE 3 15 A 250 V Check the output of SMPS on the control board Input power AC230 15 V IC02 Input DC 12 V IC02 output DC 5 V Check the setting temperature Check the indoor unit control board Check the display board Reconnect ...

Page 23: ...S Y PCB CN43 connector and measure the sensor resistance with an ohmmeter tester Connect the sensor to CN43 supply power and measure the voltage of 1 and 2 of the CN43 connector MICOM Error or Connector CN43 check Is the sensor resistance value 10KΩ 3 at the room temperature of 25 C Yes Poor ASS Y PCB Replace Below 0 5V Yes Poor ASS Y PCB Replace Over 4 9V Indoor unit room temperature sensor error...

Page 24: ...sor 3 Assemble the room pipe sensor to PCB plug in and check the voltage of connector 3 and 4 If the resistance is below 0 5V or over 4 9V replace the indoor Main PCB short or disconnected in the PCB board Temperature C 15 20 25 Temperature C 30 35 40 Resistance Value Kohm 8 31 6 94 5 83 Resistance Value Kohm 14 68 12 09 10 Others The data tolerance is 3 6 2 3 Room Pipe sensor failure Indoor unit ...

Page 25: ... 5 seconds Does the OPERATION lamp blink Does the Solid State Relay SS71 work properly Is the supply voltage of the fan motor sufficient Test rod location PCB CN72 Condition About AC 180V Normal voltage pin 3 and 5 Fan operating Yes Yes Yes Yes No No No Check as in the procedure NO power PCB is out of order PCB should be replaced Replace Motor Fan Capacitor Fan motor should be replaced Fan motor i...

Page 26: ...g out the power cord should be reconnected within 5 seconds Does the OPERATION lamp blink Yes No Yes No No No Yes Yes Outdoor unit is out of order Power relay is out of order Power relay should be replaced PCB should be checked Micom is out of order Sensor Should be replaced Room temperature sensor is out of order Check as in the procedure No Power Is the room sensor normal resistor 10 C 20 C 30 C...

Page 27: ...n start when swing button of the remote control unit pushed Voltage at pin 57 60 of micom IC04 change Squarewave Voltage at pin 2 5 of CN61 motor connector change Squarewave UP DOWN louver motor is faulty Driver IC06 08 ULN2003A is faulty Micom IC04 is faulty Normal Check as in the procedure No Power After training on the heating operation should start in 5 minutes Is the number 38 of Micom IC04 D...

Page 28: ...heck the voltage of No 3 and No 2 of the main PCB CN91 while operating the remote control When the voltage descends below 3V the assembly module PCB is normal and the main PCB is poor Then replace the main PCB 3 Replace the assembly display PCB because the module PCB is poor if the voltage between No 2 3 of CN91 maintains 5V after the remote control starts operation ...

Page 29: ... 3 1 4 14 2 14 5 14 4 14 6 2 10 4 1 6 2 11 14 1 2 3 1 1 1 1 5 1 6 1 7 3 7 8 12 5 6 6 1 CIS LATIN AMERICA EUROPE AFRICA You can search for the updated part code number through the ITSELF URL http itself sec samsung co kr 7 Exploded Views and Parts List 7 1 Indoor Unit ...

Page 30: ...ASS Y 1 1 4 DB63 00581A COVER TERMINAL HIPS 1 DB63 00588A COVER TERMINAL HIPS 1 1 5 DB93 01717R ASS Y REMOCON ASS Y 1 1 1 6 DB94 00547A ASS Y BACK BODY ASS Y 1 DB94 00508A ASS Y BACK BODY ASS Y 1 1 6 1 DB61 01779A BACK BODY HIPS 1 DB61 01780A BACK BODY HIPS 1 1 6 2 DB94 00258A ASS Y BEARING ASS Y 1 1 1 7 DB94 00040R ASS Y CROSS FAN ASS Y 1 DB94 00040F ASS Y CROSS FAN ASS Y 1 1 8 DB31 00152B MOTOR ...

Page 31: ...RATOR ASS Y 1 1 4 DB63 00581A COVER TERMINAL HIPS 1 DB63 00588A COVER TERMINAL HIPS 1 1 5 DB93 01717R ASS Y REMOCON ASS Y 1 1 1 6 DB94 00547A ASS Y BACK BODY ASS Y 1 DB94 00508A ASS Y BACK BODY ASS Y 1 1 6 1 DB61 01779A BACK BODY HIPS 1 DB61 01780A BACK BODY HIPS 1 1 6 2 DB94 00258A ASS Y BEARING ASS Y 1 1 1 7 DB94 00040R ASS Y CROSS FAN ASS Y 1 DB94 00040F ASS Y CROSS FAN ASS Y 1 1 8 DB31 00152B ...

Page 32: ... Y REMOCON ASS Y 6 DB94 00547A ASS Y BACK BODY ASS Y 6 1 DB61 01779A BACK BODY HIPS 6 2 DB94 00258A ASS Y BEARING ASS Y 7 DB94 00040R ASS Y CROSS FAN ASS Y 8 DB31 00152B MOTOR FAN IN 220 240V 50 60Hz 9 DB61 01099A HOLDER MOTOR PP 10 DB67 60030A SPRING SENSOR STS301 11 DB70 00276A PLATE HANGER SGCC M 12 DB93 02539A ASS Y CONTROL IN ASS Y 13 DB90 00992A HOLDER PIPE HIPS 14 DB94 00468D ASS Y TRAY DRA...

Page 33: ...Samsung Electronics 32 Samsung Electronics 32 7 2 Outdoor Unit 12 15 1 15 2 4 2 14 5 15 6 18 19 9 2 11 22 10 21 15 5 20 4 1 7 6 23 8 3 1 16 17 4 13 15 7 15 3 15 15 4 ...

Page 34: ...B93 02739A ASS Y CONTROL OUT ASS Y 1 DB93 02739B ASS Y CONTROL OUT ASS Y 1 15 1 2501 001236 CAPACITOR COMP 30uF 450VAC 1 1 2501 001234 CAPACITOR COMP 20uF 450VAC 1 2501 001238 CAPACITOR COMP 40uF 450VAC 1 15 2 2301 001375 CAPACITOR MOTOR 1 5uF 450VAC 1 1 1 1 15 3 DB65 40049E TERMINAL BLOCK 4P 1 1 1 1 15 4 DB93 01547B ASS Y LEAD WIRE ASS Y 1 1 DB93 01547D ASS Y LEAD WIRE ASS Y 1 1 15 5 DB35 00026D ...

Page 35: ...1 DB93 02739C ASS Y CONTROL OUT ASS Y 1 15 1 2501 001237 CAPACITOR COMP 35uF 450VAC 1 1 1 2501 001236 CAPACITOR COMP 30uF 450VAC 1 15 2 2301 001375 CAPACITOR MOTOR 1 5uF 450VAC 1 1 1 1 15 3 DB65 40049E TERMINAL BLOCK 4P 1 1 1 1 15 4 DB93 01547B ASS Y LEAD WIRE ASS Y 1 DB93 01547E ASS Y LEAD WIRE ASS Y 1 1 DB93 01547D ASS Y LEAD WIRE ASS Y 1 15 5 OLP INTERNAL 1 DB35 00028G OLP RBC12107 12500 1 DB35...

Page 36: ...MEMO 35 Samsung Electronics ...

Page 37: ...Samsung Electronics 36 Samsung Electronics 36 7 3 Ass y Control In Indoor Unit AQO S2G SHO ZS2 NO PLUG DB93 02524A AQO S2G SHO ZS2 PLUG DB93 02524C ...

Page 38: ... 001054 CASE CONTROL ASS Y MAIN PCB ASS Y TERMINAL BLOCK ASS Y SUB PCB PLATE TERMINAL LOW HOLDER WIRE CLAMP SCREW MACHINE SCREW MACHINE SCREW MACHINE ASS Y C W SUB ASS Y C W STEP MOTOR ASS Y THERMISTOR HOLDER DISPLAY WINDOW DISPLAY ASS Y HOLDER PCB POWER CORD POWER CORD SCREW MACHINE ABS ASS Y ASS Y ASS Y SGCC M T1 2 ABS PH M3xL22 TH M4xL16 PH M4xL10 ASS Y ASS Y 4P 103AT ABS HIPS PLUG NO PLUG TH M...

Page 39: ...Samsung Electronics 38 Exploded Views and Parts List Samsung Electronics 38 AQ T 12S4G SH12ZS4 DB93 02539A ...

Page 40: ...CASE CONTROL ASS Y MAIN PCB ASS Y TERMINAL BLOCK ASS Y SUB PCB PLATE TERMINAL LOW HOLDER WIRE CLAMP SCREW MACHINE SCREW MACHINE SCREW MACHINE ASS Y C W SUB ASS Y C W STEP MOTOR ASS Y THERMISTOR HOLDER DISPLAY WINDOW DISPLAY ASS Y HOLDER PCB POWER CORD POWER CORD SCREW MACHINE ABS ASS Y ASS Y ASS Y SGCC M T1 2 ABS PH M3xL22 TH M4xL16 PH M4xL10 ASS Y ASS Y 4P 103AT ABS HIPS PLUG NO PLUG TH M4xL10 1 ...

Page 41: ...ION SLEEP SELECT MODE AUTO COOL DRY FAN FAN SPEED SELECT H M L BLADE H MOVING SELECT ON OFF TIMER SELECT FUNCTION SELECT TEMPERATURE SELECT ZERO VOLTAGE DETECT BLADE CONTROL AUTO GRILLE CONTROL INDOOR FAN MOTOR CONTROL COMPRESSOR CONTROL TEMPERATURE CONTROL TIMER BUZZER CONTROL FUNCTION CONTROL TRIGGER SIGNAL SSR COMPRESSOR DRIVE OUTDOOR FAN MOTOR DRIVE STEPPING MOTOR DRIVE BUZZER DRIVE FUNCTION D...

Page 42: ...41 Samsung Electronics 9 PCB Diagram 9 1 ASS Y MAIN PCB 7K 9K 12K DB93 02447A TOP ...

Page 43: ...Samsung Electronics 42 PCB Diagram BOTTOM ...

Page 44: ...ONTROLLER 255 DIP 8P 300MIL PLASTIC 0 3 700V 40TO 150C 1 530MA ST NTC1 THERMISTOR NTC 22OHM 1 4A 3100K 9 5mW C 7 0 1 VA71 VARISTOR 560V 2500A 17 5x7 5mm TP 1 R609 R CHIP 560ohm 5 1 8W TP 2012 1 R102 R CHIP 100ohm 5 1 8W TP 2012 1 R209 R501 R601 R603 R CHIP 10Kohm 5 1 8W TP 2012 6 R605 R908 R210 R211 R212 R301 R CHIP 1Kohm 5 1 8W TP 2012 11 R302 R401 R402 R404 R602 R604 R610 R103 R CHIP 220ohm 5 1 ...

Page 45: ...02 FUSE CLIP 250V 7 5A 30mohm 1 F702 FUSE CARTRIDGE 250V 3 15A TIME LAG GLASS 5x20mm 1 CN71 CONNECTOR HEADER 1WALL 3P 1R 7 92mm STRAIGHT SN BLU 1 CN72 CONNECTOR HEADER 1WALL 3P 1R 7 92mm STRAIGHT SN WHT 1 CN91 CONNECTOR HEADER BOX 8P 1R 2mm ANGLE SN 1 CN61 CONNECTOR HEADER BOX 5P 1R 2mm ANGLE SN WHT 1 CN43 CONNECTOR HEADER BOX 4P 1R 2mm STRAIGHT SN 1 CN44 CONNECTOR HEADER BOX 3P 1R 2 5mm ANGLE TIN...

Page 46: ... 08 WHT 1 SNA 4 LED LAMP GRN SM3517 2 SNA 5 LED LAMP ORG SO3517 1 SNA 6 RESISTOR 470ohm 1 2W 1 SNA 7 MODULE REMOCON FRP4021H10 1 SNA 8 DIODE 1N4148 1 SNA 9 C CERAMIC 1nF 50V 1 SNA 10 C CERAMIC 100nF 50V 1 SNA 11 JUMPER 10mm 1 SNA No Q TY Remark Description Specification 9 2 ASS Y SUB PCB 7K 9K 12K DB93 02525A ...

Page 47: ...Samsung Electronics 46 10 Wiring Diagram 10 1 Indoor Unit 7K 9K 12K This Document can not be used without Samsung s authorization Code No DB98 15135A ...

Page 48: ... authorization 10 2 Outdoor Unit SH07ZS2X SH09ZS2X UQT12S4GB UQT12S4GE Code No DB98 15123A C1 MOTOR CAPACITOR FM FAN MOTOR C2 COMP CAPACITOR O L P OVER LOAD PROTECTOR SH12ZS4X Code No DB98 16523A C1 MOTOR CAPACITOR FM FAN MOTOR C2 COMP CAPACITOR O L P OVER LOAD PROTECTOR ...

Page 49: ...ring Diagram This Document can not be used without Samsung s authorization SH07ZS2AX SH09ZS2AX SH12ZS4AX UQ07S2GE UQ09S2GE UQ12S4GE Code No DB68 01624A C1 MOTOR CAPACITOR FM FAN MOTOR C2 COMP CAPACITOR O L P OVER LOAD PROTECTOR ...

Page 50: ...49 Samsung Electronics 11 Schematic Diagram 11 1 Indoor Unit 7K 9K 12K This Document can not be used without Samsung s authorization ...

Page 51: ...MEMO Samsung Electronics 50 ...

Page 52: ...MEMO 51 Samsung Electronics ...

Page 53: ...MEMO Samsung Electronics 52 ...

Page 54: ...e Manual is a property of Samsung Electronics Co Ltd Any unauthorized use of Manual can be punished under applicable International and or domestic law Samsung Electronics Co Ltd Mar 2004 Printed in Korea Code No DB98 16693A 2 ...

Reviews: