Summary of Contents for THxxxEAVx

Page 1: ...ENGLISH System Air Conditioner Cooling and Heating ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN DB98 24340A 5 S E F I D P G R INSTALLATION MANUAL CassetteType Series TH EAV ...

Page 2: ...nit If performed by unauthorized personnel these operations may cause electric shocks or fires Do not place containers with liquids or other objects on the unit All the materials used for the manufacture and packaging of the air conditioner are recyclable The packing material and exhaust batteries of the remote control optional must be disposed of in accordance with current laws The air conditione...

Page 3: ...8 Connecting the Refrigerant Pipe 9 Cutting Flaring the Pipes 10 Performing Leak Test Insulation 11 Drainpipe and Drain Hose Installation 12 Connecting the Connection Cord 14 Assigning Address to Indoor Unit 15 Installing the Safety Net Air blocking kits 17 Technical Specification Product feature 17 Troubleshooting 18 Additional Accessories 22 ...

Page 4: ...d furniture could affect the supply and discharge of air Without leaving the required minimum space around the unit as shown in the drawing In scarcely ventilated areas On surfaces that are unable to support the weight of the unit without deforming breaking or causing vibrations during the use of the air conditioner In a position that does not enable the condensate drainage pipe to be correctly in...

Page 5: ...d safely The indoor unit must be installed in this way that they are out of public access Not touchable by the users ENGLISH Space Requirements for Indoor Unit The units must be installed according to distances declared in order to permit accessibility from each side either to guarantee correct operation of maintenance or repairing products The unit s parts must be reachable and removable complete...

Page 6: ... Unit continued Dimension and weight 026 035 052 060 Net dimension Indoor unit mm 575X260X575 Panel size 670X35X670 Outdoor unit 790X548X285 880X638X310 880X798X310 Net weight Indoor unit Panel kg 19 6 Outdoor unit 32 6 50 57 Unit mm 577 610 Ceiling opening 577 610 Ceiling opening 476 Suspension position 518 Suspension position Required space Fresh air intake hole Suspension bolt 4 M8 M10 670 670 ...

Page 7: ...in order to be able to use it to perform the required operations on the indoor unit 4 Screw eight nuts to the suspension bolts making space for hanging the indoor unit CAUTION You must install the suspension bolts more than four when installing the indoor unit 5 Hang the indoor unit to the suspension bolts between two nuts Note Piping must be laid and connected inside the ceiling when suspending t...

Page 8: ...herefore all insert gas must be purged before connecting the assembly piping Unscrew the pinch pipe at the end of each refrigerant pipe Result All inert gas escapes from the indoor unit Note To prevent dirt or foreign objects from getting into the pipes during installation do NOT remove the pinch pipe completely until you are ready to connect the piping ...

Page 9: ... excess foam insulation 4 Be sure that there must be no crack or wave on the bended area 5 It would be necessary to double the insulation thickness 10mm or more to prevent condensation even on the insulator when if the installed area is warm and humid 6 Do not use joints or extensions for the pipes that connect the indoor and outdoor unit The only permitted connections are those for which the unit...

Page 10: ... 19 05 mm 3 4 22 23 mm 7 8 1 3mm 1 8mm 2 0mm 2 2mm 2 2mm 2 2mm 5 Check that the flaring is correct referring to the illustrations below for examples of incorrect flaring 6 Align the pipes and tighten the flare nuts first manually and then with a torque wrench applying the following torque Valve Flare nut Valve cap Pressure port cap Valve needle Pressure port Wrench mm N m Wrench mm N m Wrench mm N...

Page 11: ...ing to the outdoor unit 4 The pipes and electrical cables connecting the indoor unit with the outdoor unit must be fixed to the wall with suitable ducts LEAKTESTWITHNITROGEN beforeopeningvalves In order to detect basic refrigerant leaks before recreating the vacuum and recirculating the R410A it s responsible of installer to pressurize the whole system with nitrogen using a cylinder with pressure ...

Page 12: ...se the height of the drainpipe install the drainpipe straightly within 300 mm from the flexible hose port If it is raised higher than 550 mm there can be water leaks 300mm or less 1 100 or more Flexible hose Band joint Ceiling 550mm or less 20mm or more Drainpipe Flexible hose Care must be taken when installing the drainpipe and drain hose for the indoor unit so that condensate water is drained co...

Page 13: ...e water about 2 0 liters 1 Turn the cover drain pump then pull it out 2 Pour water into the indoor unit as shown in figure Note If you do not pour water inside the water supply intake water may spill from the indoor unit 3 Confirm that the water flows out through the drain hose Note You can check the drainage only when the air conditioner is in cool mode 4 Reassemble the cover drain pump Note New ...

Page 14: ... and connect the cable to terminals refer to the figure below 3 Route the other end of the cable to the outdoor unit through the ceiling the hole on the wall 4 Reassemble the electrical component box cover carefully tightening the screw Indoor Outdoor units Power 10 Power cable Max Length Power supply 220 240V 50Hz 0 75mm2 3wires 1Km Communication 0 75mm2 2wires 1Km Size of the cables used to inter...

Page 15: ...ioning system plan 2 The address of the indoor unit is assigned by adjusting MAIN SW02 and RMC SW04 rotary switches K 1K 2 K 3K 4 K 5K 6 K 7K 8 K 9 K 1 0K 1 1K 1 2 SW02 MAIN SW04 RMC SW05 SW06 SW07 3 The MAIN address is for communication between the indoor unit and the outdoor unit Therefore you must set it to operate the air conditioner properly ...

Page 16: ...ory is not installed you do not have to set the RMC address However adjust K1 and K2 switches of the SW05 DIP switch to ON position in this case 6 Set the MAIN address by adjusting the rotary switch SW02 from 0 to 9 Each indoor unit connected to the same outdoor unit must have different address i e If an indoor unit does not have an optional accessory and its MAIN address is 0 SW02 MAIN SW04 RMC S...

Page 17: ...r unit installation manual Vacuum and refrigerant charge see the outdoor unit installation manual Install the safety net after installing the connection cord and fixing electric component box cover For your safety you must install the safety net For details about installing the panel refer to the manual for the panel 1 Uncover the wrap of safety net 2 Fix the safety net to the electric component c...

Page 18: ...en Red Yellow Green Orange Power reset X X X X Error of temperature sensor in the indoor unit Open Short X X X X Error of heat exchanger sensor in the indoor unit X X X Error of the outdoor temperature sensor Error of the condensor temperature sensor Error of the discharge temperature sensor X X X Indoor and outdoor unit time out Abnormal data reception more than 60 packet Indoor unit is not conne...

Page 19: ...nt leakage Gas leak Self diagnosis Outdoor fan restriction error Inverter Inverter compressor operation failure Inverter DC peak error Inverter DC Link voltage 150V or less 410V or more Inverter Compressor rotation error Inverter Electric current error Inverter DC Link sensor error Inverter EEPROM READ WRITE error Inverter Inverter zerocrossing error Setting the outdoor unit capacity option error ...

Page 20: ...mp Vlimit error Coil temp sensor error 1min time out Comm Fan error OTP error Comp rotation error main main Operation condition secession DC Link voltage sensor error I_Trip error PFC Over current GAS Leak error AC Line Zero Cross Signal out Capacity miss match Troubleshooting continued Wired remote controller If an error occurs is displayed on the wired remote controller If you would like to see ...

Page 21: ...sor secession Indoor Eva In and Out sensor secession error Secondary Electronic heater sensor 1 error Secondary Electronic heater sensor 2 error Secondary Electronic heater sensor 3 error Indoor unit float S W 2nd detection Indoor fan error Mixed operation error EEPROM error EEPROM option setting error Error regarding special sales taxes Electronic heater discharge temperature protection error Ele...

Page 22: ...ual Installation manual 1 1 1 1 Wireless Remote Controller Accessories Type B Batteries for remote controller M4x12 tapped screw Remote control holder User s manual Installation manual 2 2 1 1 1 Wireless remote controller 1 Centralized Controller Accessories Cable tie Cable clamp M4x16 tapped screw User s manual Installation manual 2 5 7 1 1 Centralized controller 1 Wireless Remote Controller Acce...

Page 23: ...e to install the centralized control you must install the transmitter in the outdoor unit Cable tie Cable clamp M4x16 tapped screw User s manual Installation manual 2 6 7 1 1 Function controller 1 Transmitter power cable Transmitter communicationcable Installation manual 1 1 1 Transmitter 1 ...

Page 24: ......