Dimension

SVD-4120AN

SVD-4120AP

SVD-4120AWN SVD-4120AWP

* Design and specifications are subject to change without notice

Power Source

Power Consumption

Image Sensor

Total Pixels

Effective Pixels

LENS TYPE

Maximum Aperature Ratio

Angle of View

Scanning System

Synchronization

Video Output

Resolution

Wide Dynamic Range

Gain Control

Electric Shutter Speed

SENSE UP

IRIS MODE

WHITE BALANCE

Min. Illumination

S/N(Y signal)

Motion Detection

O.S.D

SSNR

PRIVACY Function

Operating Temperature

Operating Humidity

Dimension(mm)

Weight(W/O Lens & Power Cord)

Angle

Item

DC 12V / AC 24V compatible

280mA(DC) / 3.8W(AC)

1/3”, Vertical double density interline CCD

811(H)x508(V), 1/3”CCD

759(H)x596(V), 1/3”CCD

811(H)x508(V), 1/3”CCD

759(H)x596(V), 1/3”CCD

768(H)x494(V), 1/3”CCD

752(H)x582(V), 1/3”CCD

768(H)x494(V), 1/3”CCD

752(H)x582(V), 1/3”CCD

2.5X Vari-Focal,f=3.8~9.5                     

2.4X Vari-Focal,f=2.5~6.0

1:1.3~2.0

1:1.3~1.9

H: 74.2˚~30.0˚, V: 54.0˚~22.4˚, D: 96.8˚~37.4˚

H: 108.2˚~47.6˚, V: 80.4˚~35.6˚, D:136.6˚~59.4˚

Internal / Line Lock selectable

500TV Lines

ON / OFF / AUTO

AGC-L, AGC-H, OFF selectable

1/60~1/200,000sec

1/50~1/200,000sec

1/60~1/200,000sec

1/50~1/200,000sec

Built-in(selectable limit~X128)

DC Drive

W-ATW / S-ATW / AWC / MANUAL

0.003Lux(Sense Up) / 0.3Lux(F1.3)

50dB (Weight ON)

MD1 / MD2 / OFF

Built-in

LOW / MIDDLE / HIGH /OFF

ON / OFF(4 Programmable Zone)

-10˚C ~ +50˚C (14˚F ~ 122˚F)

30% ~ 90% RH

f150(W) x 130(H)

1.4kg

Panning : 340˚ ,  Tilt : 70˚

COLOR DOME CAMERA

User’s Manual

35

COLOR DOME CAMERA

User’s Manual

34

Specifications

Ø 148mm

126mm

83.5mm

46mm

85mm

85mm

85mm

1.0V[p-p]NTSC composite,

75W/BNC Connector

1.0V[p-p]PAL composite,

75W/BNC Connector

1.0V[p-p]NTSC composite,

75W/BNC Connector

1.0V[p-p]PAL composite,

75W/BNC Connector

2:1 Interlaced 525

Lines/60Fields/30Frames

2:1 Interlaced 625

Lines/50Fields/25Frames

2:1 Interlaced 525

Lines/60Fields/30Frames

2:1 Interlaced 625

Lines/50Fields/25Frames

Summary of Contents for SVD-4120A

Page 1: ...rea 462 703 TEL 82 31 740 8137 41 FAX 82 31 740 8145 SAMSUNG OPTO ELECTRONICS AMERICA INC SOA Closed Circuit Division 40 Seaview Drive Secaucus NJ 07094 U S A TEL 201 902 0347 FAX 201 902 0429 SAMSUNG OPTO ELECTRONICS UK LTD SOUK Samsung House 1000 Hillswood Drive Hillswood Business Park Chertsey Surrey KT16 OPS TEL 44 0 1932 45 5308 FAX 44 0 1932 45 5325 TIANJIN SAMSUNG OPTO ELECTRONICS CO LTD TS...

Page 2: ...dio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications not expressly approved by the manufacturer...

Page 3: ...t shows clean and obvious image in low luminance Electronic DAY NIGHT In normal or high luminance camera maintains color mode On the contrary it get changed into B W mode in low luminance Auto Iris Vari Focal Lens Built In The focal length of lens is 3 8 to 9 5 mm equivalent to 2 5x zoom 2 5 to 6 0mm equivalent to 2 4x zoom SVD 4120AW The built in lens allows the camera to have a Wider Dynamic Ran...

Page 4: ... 27 28 28 30 32 10 11 13 13 14 Operating Your Camera Setting Up The Menu CAMERA ID BACKLIGHT WHITE BALANCE MOTION DETECTION IRIS LEVEL CONTROL SHUTTER SPEED CONTROL SESE UP GAIN SSNR SPECIAL Troubleshooting 34 Dimention 35 Specifications Connection Precautions Composition Name and Function of Each Section ...

Page 5: ...ighting change or flicker can cause the camera to work improperly Do not touch the front lens of the camera It is one of the most important parts of the camera Be careful not to be stained by fingerprint Do not drop the camera or subject them to physical shocks It can cause malfunctions to occur Never keep the camera face to strong light directly If the camera is exposed to spotlight or object ref...

Page 6: ...tion of Each Section COLOR DOME CAMERA User s Manual 11 COLOR DOME CAMERA User s Manual 10 1 SVD 4120A AW 2 Instruction Manual 3 Quick Install Guide 5 Ø5 Tapping Screws 4EA 6 Template 4 Wrench 7 Video Output Cable for installer ...

Page 7: ...re item UP Button move cursor to the up select the desired feature item LEFT Button move cursor to the left change the status of the selected feature Video Output Terminal Video Output Terminal to Monitor Video Output Jack Power Input Jack Shield Case Dome Cover Connection Connecting to Monitor Connect the VIDEO OUT jack to the VIDEO IN jack of monitor As the connecting method varies with the inst...

Page 8: ... 52mm 2 18 0 83mm 2 Resistance Ω m 0 078 0 050 0 030 0 018 Voltage Drop V m 0 028 0 018 0 011 0 006 Be sure to connect power only after all the installation is complete Note that AC or DC adaptor is not supplied with camera Use the UL listed class 2 power transformer of AC 24V adaptor Ground should be connected to the GND terminal Notes Configuration of The Menu SETUP MENU CAMERA ID see page 17 OF...

Page 9: ...ION DET OFF IRIS LEVEL SHUTTER OFF SENSE UP OFF GAIN AGC L SSNR MIDDLE SPECIAL EXIT Change the status using the LEFT or RIGHT button Select the function using the UP or DOWN button 3 Change the status of the selected feature using the LEFT or RIGHT button 4 When completed move the arrow indicator to EXIT and press the SET button If you enter a CAMERA ID the name will be displayed in the screen mon...

Page 10: ...eps and until you create the full name you want If you make a mistake while entering name Move the cursor to CLR press SET button After erasing the character from right to left correct the character again Notes CANERA ID POS CLR RESET END CAMERA ID POS CLR RESET END 5 Select the position at which the CAMERA ID will be located on the screen Move the cursor to POS and press SET button The CAMERA ID ...

Page 11: ...BAL W ATW If you select WDR mode the following phenomenon may appear by lighting condition In these cases do not select WDR mode Unnatural color change or unnatural phenomenon on the screen Noise of bright part on the screen According to the area of bright part on the screen there may be the difference of WDR performance so be sure to adjust the degrees of the visual angle when installing your cam...

Page 12: ...following conditions in these cases select the AWC mode When the scene contains mostly high color temperature object such as a blue sky or sunset When the scene is dim If your camera faces fluorescent lamp directly or is installed in the place of the changing illumination Notes MOTION DETECTION Whenever your camera detects motion of object displaying MOTION DETECTED with the number counted up on t...

Page 13: ...L the areas sensitivity is increased or decreased for object After selecting zone and sensitivity perform a test operation to make sure it works properly If the lighting flickers the motion detection feature might not work properly The object should occupy 10 or more of its zone The bigger the object the higher sensitivity If the brightness of an object changes rapidly by sudden lighting change th...

Page 14: ...ETUP CAMERA ID OFF BACKLIGHT WDR WHITE BAL W ATW MOTION DET OFF IRIS LEVEL SHUTTER OFF SENSE UP OFF GAIN AGC L 4 When completed press the SET button MANUAL SET VALUE 1 60 PRESS SET TO RETURN NTSC Models MANUAL SET VALUE 1 50 PRESS SET TO RETURN PAL Models For effective 1 100 1 120 mode set WDR mode in BACKLIGHT menu to OFF 1 100 1 120 mode is not effective with WDR mode If you choose MANUAL mode y...

Page 15: ...To reduce the noise on the screen 1 Press the SET button to display the setup menu and move the arrow indicator to SSNR using the UP or DOWN button 2 Set SSNR to desired mode using the LEFT or RIGHT mode LOW low reduction of the noise MIDDLE middle reduction of the noise HIGH high reduction of the noise OFF Deactivation SETUP CAMERA ID OFF BACKLIGHT WDR WHITE BAL W ATW MOTION DET OFF IRIS LEVEL SH...

Page 16: ...z PAL Models INT Internal synchronization OFF External line lock synchronization If you choose L L you can adjust the desired phase Press the SET button You can adjust the desired phase from 0 to 270 PRIVACY To mask area which you want to mask OFF Deactivation ON Privacy mode activated Press the SET button Move the arrow indicator to area you want to mask Set ON using LEFT or RIGHT button Press th...

Page 17: ...ns stained with dirt Clean your lens with soft clean cloth Set the monitor to proper condition If the camera is exposed to too strong light change the camera position Adjust the lens focus properly Adjust the contrast feature of the monitor If you have an intermediate device set the 75Ω Hi z properly refertopage13 Check that you have properly connected the camera to an appropriate power source Hav...

Page 18: ...X Vari Focal f 3 8 9 5 2 4X Vari Focal f 2 5 6 0 1 1 3 2 0 1 1 3 1 9 H 74 2 30 0 V 54 0 22 4 D 96 8 37 4 H 108 2 47 6 V 80 4 35 6 D 136 6 59 4 Internal Line Lock selectable 500TV Lines ON OFF AUTO AGC L AGC H OFF selectable 1 60 1 200 000sec 1 50 1 200 000sec 1 60 1 200 000sec 1 50 1 200 000sec Built in selectable limit X128 DC Drive W ATW S ATW AWC MANUAL 0 003Lux Sense Up 0 3Lux F1 3 50dB Weight...

Page 19: ...onment CCTV Camera Model Name SVD 4120A AW Beginning Serial NO S4100002 Year of Manufacture 2004 1 2 Conformance to EN 50081 1 1992 EMC Directive 89 336 EEC and 92 31 EEC EN 50130 4 1996 We the undersigned here by declare that the equipment specified above conforms to the above Directive s Manufacturer SAMSUNG TECHWIN CO LTD Legal Representative in Europe Signature Signature Full Name YOUNG TAEK S...

Page 20: ...MEMO MEMO ...

Reviews: