PHYSICAL

ELECTRICAL

Current dissipation: 55 mA (Colored: 35 mA)

Power Consumption: 0,6 W (Colored: 0,42 W)

Operating power : DC 12V

Maximum serial connection : 50 modules

Electronic dimming control supported

THERMAL

Cooling : Ambient air

Maximum operating temperature : 40˚C 

Minimum operating temperature : -20˚C 

Maximum storage temperature : 60˚C 

Minimum storage temperature : -30  C 

SPECIFICATIONS

Use precautions to avoid damages to the product or injuries of users. Any actions against following contents will cause serious 

issues such as malfunction, electric shock, or burn.

USE DC12V ONLY

DC12V

DO NOT USE AC INPUT

AC  INPUT

Do not cut or rejoion wires while product 

is connected wth live power source

Maximum driver quantity per serial 

connection is limited. Failure causes overload 

of current and damages to the product

Refer to ‘WIRE THICKNESS’ table to use proper 

LED module

Failure will cause dimmed output

module is limited. Refer to ‘CONNECTION 

WITH POWER SUPPLY’ on page 2

Do not use the product under circumstances 

listed below
 - High temperature spots over 60˚C (140˚F)

 - Spots draw extreme moisture or dust

Avoid performing installation under rain or 

high humidity for outdoor use

Do not perform actions listed below
 - Alter or modify

 - Touch LED lamps with sharp objects

 - Put glue or silicon over the LED lamps

PRECAUTIONS

PREPARATION

PREPARE CHANNELS

1. Clean moisture and dust inside

2. Make holes

3. Use bushing to protect wires

2. Make holes for wires from modules to SMPS.

3. Without bushins, wires will easily be cut and short-circuit will occur.

SUPPLIES REQUIRED

TOOLS REQUIRED

Wire Nuts, Cable Ties, IDC Connectors, VCTF(PLTC) Cable,

(Optional : Silicon and Screws)

Wire Stripper, Drill, Screw Driver, Wiper

Epoxy Molding

double sided tape 

IP65

Nonpolar

Input Connection

  

FARD lighting GmbH     Seestrasse 20      D - 14974 Ludwigsfelde OT Genshagen

Tel. +49 - (0)3378 / 2003-0       Fax +49 - (0)3378 / 2003-29

[email protected]       www.fard-lighting.de

Summary of Contents for STAR N03

Page 1: ... use proper LED module Failure will cause dimmed output module is limited Refer to CONNECTION WITH POWER SUPPLY on page 2 Do not use the product under circumstances listed below High temperature spots over 60 C 140 F Spots draw extreme moisture or dust Avoid performing installation under rain or high humidity for outdoor use Do not perform actions listed below Alter or modify Touch LED lamps with ...

Page 2: ...se dimmed spots or uneven appearance of light on the surface LAYOUT DENSITY GUIDELINES RECOMMENDED PITCH PER DEPTH 120 mm 120 mm 200 mm 150 mm 100 mm 100 mm 70 mm 80 mm RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH 80 mm 200 mm 400 mm 316 mm Use 10 shorter length than usual for circular arrange CONNECTION WITH POWER SUPPLY Output W Model Name Max Q TY Colors Recommended Extension Wire Output A Max ...

Page 3: ...E LAYOUT Refer to LAYOUT DENSITY GUIDELINES on page 2 to determine spacing and amount of LEDs required SUPPORTS FOR OUR SIGNMATES Ask us to obtain accurate layout Stroke Width Channel Depth 2 PEEL AND STICK Using predetermined layout and LED placement from step 1 remove 3M tape on the back of modules attached on the surface CAUTION When handling the module avoid pressing down directly on top of LE...

Page 4: ...ad connection or reverse polarity connection between the modules that light and the modules that don t light Check this connection Beginning of a leg lights but the entire leg does not light or lights intermittently S LED is designed so if one module fails it will not cause the entire sign or leg to go out If one module does not light but all others in the leg do replace this module with a new one...

Reviews: