overview
14_
overview
Item
Description
c
System, Power,
SD Indicators
POWER
ON : While the power is on
OFF : If the power is off
Reset Button
Resets the camera settings to the default. Press and hold it for about 5
seconds to turn off the system indicator and restart the system.
J
If you reset the camera, the network settings will be adjusted so that
DHCP can be enabled. If there is no DHCP server in the network, you
must run the IP Installer program to change the basic network settings
such as IP address, Subnet mask, Gateway, etc., before you can
connect to the network.
Power Port
Used to plug the power cable.
GND
Used for earth-grounding.
Network Port
Used to connect a PoE or LAN cable.
I/O Port
ALARM IN
Used to connect the alarm input signal.
ALARM OUT
Used to connect the alarm output signal.
ALARM COM Common port where the alarm output signal is connected.
GND
Used for earth-grounding.
RS-485+
RS-485 Data line
RS-485-
RS-485 Data line
Video Out Port
Analog video output port. (for installation)
J
RS-485 port only supports direct connection with pan/tilt driver and external connections of the
RS-485 controller is not supported.