background image

 

SMH1611 

2/17/2012 

Fast Track Troubleshooting 

Publication #  rsSMH1611   Revision Date 1/19/2012

 

Model: SMH1611*/XAA  

 

IMPORTANT SAFETY NOTICE

 – 

“For Technicians Only”

  This service data sheet is 

intended for use by persons having electrical, electronic, and mechanical experience 
and knowledge at a level generally considered acceptable in the appliance repair trade.  
Any attempt to repair a major appliance may result in personal injury and property 
damage.  The manufacturer or seller cannot be responsible, nor assume any liability for 
injury or damage of any kind arising from the use of this data sheet. 

SUPPORT INFORMATION 

Training — Plus One 

http://my.plus1solutions.net/clientPortals/samsung/ 

Help — GSP

http://gspn3.samsungcsportal.com

  

Samsung Product Support TV 

http://support-us.samsung.com/spstv/howto.jsp 

Customer information videos and chat programs. Programs for Fridges, Laundry, Ranges & D/W 

Oven Thermal Cutout 

The oven thermal cutout (Cavity TCO) is located on the top side of the oven cavity beside the exhaust duct with a tem-
perature rating of 248°F (120°C) and is 

NOT

 resettable. 

Hood Thermal Cutout 

This cutout will protect the touch control from excessive heat by turning the vent fan on at low speed. If the surface units 
of the range are used for long periods of time heat will build up and could damage the microwave control. In order to pre-
vent this, a thermal cutout is installed on the duct behind the control. This cutout will close (158°F/70°C - vent fan ener-
gized) and open (104°F/40°C - vent fan de-energized) depending on temperature. 

Magnetron Thermal Cutout 

The magnetron thermal cutout is located above the leads to the magnetrons. It is designed to prevent damage to the 
magnetron if an overheated condition develops in the tube due to cooling fan failure, obstructed air ducts, dirty or 
blocked air intake. Under normal operation, the magnetron thermal cutout remains closed. However, when abnormally 
high temperatures are reached within the magnetron, the magnetron thermal cutout will open at 302°F (150°C) causing 
the oven to shut down. After the temperature drops to 140°F (60°C) it will reset and cooking will be able to resume. 

Bottom Thermal Cutout 

During a fire on the stove the heat could be intense enough to close the Hood Thermal Cutout and force the fan to run. 
While at moderate high temperature we do want it to run, however during a fire it is advantageous to NOT have the vent 
fan running. So if a fire were to start on the stove top the Bottom Thermal Cutout would open at 248°F (120°C) and re-
move all power to the microwave oven.  This cutout is 

NOT

 resettable. 

To Test Blower Windings:  

1. 

Disconnect power and remove grill.  

2. 

Open control panel and discharge capacitor.  

3. 

Continuity test across the two wires of the run capacitor should be approximately 120 ohms of resistance. This test 

allows you to read across all windings at the same time.

 

Model name 

ASSY CONTROL PANEL 

SMH1611B/XAA 

DE94-02411A 

SMH1611W/XAA 

DE94-02411B 

SMH1611P/XAA 

DE94-02411C 

SMH1611S/XAA 

DE94-02411D 

SE error.  

Switch membrane not 

available.  Order Control Panel. 

Error Code 

Cause and countermeasure 

-SE- 

Key short error(10 sec.). Replace assy 

control panel or smart board. 

Microwave cover assembly 

The front of the top cover has flanges that must fit inside the front 
frame and vent, and the bottom goes above the bottom cover.  Start 
with the left side and hold in place with one screw once engaged.  
Leave the display loose so you can see that the right side is engaged 
properly.  Then mount display and the vent, ensuring the vent en-
gages the flange. 

Reviews: