COLOR DOME CAMERA
User’s Manual
28
COLOR DOME CAMERA
User’s Manual
29
Operating Your Camera
COMM ADJ (Communication Adjustment) :
This function sets up the camera communication status when controlling the camera
through an external control device.
…
1)
…
When the SPECIAL menu screen is displayed, press the Function Setup switch
so that the arrow indicates ‘COMM ADJ’.
… …
2)
…
Set up the mode using the Function Setup witch.
- AREA SEL
: You can select up to 12 PRIVACY areas.
- MODE
: Determines whether to use the area selected in the AREA SEL.
- MASK COLOR : Determine area color. You can select Green, Red, Blue, Black, White, Gray.
- MASK TONE : Adjust the brightness of MASK COLOR.
- TOP/BOTTOM/LEFT/RIGHT : Adjust the size and position of the selected area.
- RETURN
: Select this to save the PRIVACY menu settings and return to the SPECIAL menu.
- CAM ID : Determines the camera's identification
number (between 0 and 255).
- BAUD RATE : You can select 2400/4800/9600/19200
/38400/57600 bps.
- UART MODE : You can select NONE, EVEN or ODD
for the parity bits.
- RET PKT : Determines whether to send a command back to the controller device when
a communication control command is sent to the camera.
- DISP CAM ID : Display camera title on top left corner of the screen.
* Initial value of communication adjustment
Item
Camera ID
BAUD RATE
UART MODE
PET PKT
Initial value
1
9600
8-NONE-1
ENABLE
Select a desired EXIT mode using the Left and Right buttons depending on the camera purpose.
- SAVE
: Save the current settings and exit the MAIN SETUP menu.
- NOT SAVE : Do not save the current settings and exit the MAIN SETUP menu.
- RESET
: Resets the camera settings to the factory defaults. Language and Monitor
settings are not initialized.
LANGUAGE : You can select the menu language according to your requirements.
RETURN : Select this to save the SPECIAL menu settings and return to the MAIN
SETUP menu.
EXIT
Troubleshooting
If you have trouble operating your camera, refer to the following table.
If the guidelines do not enable you to solve the problem, contact an authorized technician.
●
Nothing appears on the screen.
▶
Check that the power cord and line connectionbetween the camera and monitor are
fixed properly.
▶
Check that you have properly connected VIDEO cable to the camera VIDEO output jack.
●
The image on the screen is dim.
▶
Is lens stained with dirt? Clean your lens with soft, clean cloth.
▶
Set the monitor to proper condition.
▶
If the camera is exposed to too strong light, change the camera position.
●
The image on the screen is dark.
▶
Adjust the contrast feature of the monitor.
▶
If you have an intermediate device, set the 75
Ω
/ Hi-z properly.
●
The camera is not working properly, and the surface of the camera is hot.
▶
Check that you have properly connected the camera to an appropriate power source.
●
The SENS-UP function does not work.
▶
Check that AGC of EXPOSURE SETUP menu is ‘OFF’.
▶
Check that SHUTTER of EXPOSURE SETUP menu is ‘A.FLK’ or ‘MANUAL’.
●
The Motion Detection function does not work.
▶
Check that MOTION DET of SPECIAL SETUP menu is ‘OFF’.
●
Color is not correct.
▶
Check the setting of WHITE BAL SETUP menu .
●
The screen flickers continually.
▶
Check that direction of camera turns toward the Sun.
●
When coaxial communication is not available:
▶
Make sure that the camera and monitor are installed within the recommended distance.
▶
Use the video amplifier equivalent to coaxitron if the recommended installation
distance is exceeded.
• As the DIS function uses the digital zoom the camera's resolution will decrease.
• DIS doesn’t operate when background illumination is too low.
• DIS doesn’t operate when object pattern is monotonic as like sky or white wall.
Notes
DIS (Digital Image Stabilizer) :
This function mitigates any picture movement due to external factors such as wind.